Furuno IF-NMEASC manual Setting Up Nmea Ports, Port no Sentence Baud rate bps Tx interval ms

Page 13

3. ADJUSTMENTS

3.2Setting Up NMEA Ports

Ports J4 and J5 output data in NMEA 0183 format. Select the data to output from those ports, along with baud rate and output interval. The default settings are as shown in the table below.

Default settings for ports 2 and 3

Port no.

Sentence

Baud rate (bps)

Tx interval (ms)

 

 

 

 

J4 (Port 2)

HDT (Heading)

4800

100

 

 

 

 

J5 (Port 3)

ATT (Heading, pitch, roll)

38400

25

 

HVE (Heave)

 

 

 

 

 

 

1.Grasp the cover at its right and left sides, pull the cover outward slightly and then lift the cover to remove it.

2.Open the inner cover and turn on the power.

On the circuit board, find the heading indication, several LEDs, and four operating buttons. The Heading LED is lit.

When offset is minus

Offset

Port 2

Port 3

OUTPUT

PROCESSING

0

3

Heading Pitch Roll

Sentence Bps Output

Interval

Sentence Bps Output

Interval

Use the [Menu/Cancel] button to show the heading indication. Push the [Enter] button to show the heading offset value.

Operating buttons

Menu/

Cancel

Enter

-

+

3.Push the [Menu/Cancel] button several times to light the Sentence LED on the Port 2 line.

4.Push the [Enter] button. The Sentence LED starts flashing and the sentence currently select- ed to output from port 2 is shown with a numeric. See the illustration below for numeric and data sentence.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTPUT

PROCESSING

Sentence

 

0

 

0

0

 

 

3

LED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Offset

Heading

 

 

Pitch

 

 

 

 

Roll

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Port 2

Sentence

 

 

Bps

 

Output

 

 

 

Interval

 

 

 

 

 

 

 

 

 

 

 

 

 

Port 3

Sentence

 

 

Bps

 

Output

 

 

 

Interval

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Menu/

 

Enter

 

-

 

 

 

 

+

 

Cancel

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Current sentence setting (example: 1: HDT (Heading, true))

Other indications:

2:HDG (Heading, Variation, Deviation)

3:HDM (Heading, Magnetic)

4:ATT (Heading, pitch, roll) and HVE (Heave)

5:VTG (Course over ground and ground speed) GGA (Global positioning system(GPS fix data) ZDA (Date and time)

6:RMC (Recommended minimum specific GPS/TRANSIT data)

ZDA (Date and time)

7:Sentences of 4 and 5.

8:Sentences of 6 and 1.

5.Push the [+] or [-] button to display the numeric corresponding to the data sentence you wish to output.

6.Push the [Enter] button. The sentence LED stops flashing.

5

Image 13
Contents Model IF-NMEASC Page Important Notices Safety instructions for the operator Safety InstructionsIii Table of Contents Word to the Owner of the IF-NMEASC ForewordSystem Configuration Mounting Mounting ProcedureEquipment List Name Type Code No Qty RemarksWiring Cable construction LEDs and Equipment Status AdjustmentsLED state and equipment status Port no Sentence Baud rate bps Tx interval ms Setting Up Nmea PortsOutput Processing Sentence Output interval ms Output Processing Heading, Pitch and Roll OffsetsOperation Preventive Maintenance MAINTENANCE, TROUBLE- ShootingCheck point Remedy Symptom Possible trouble Remedy TroubleshootingReplacing the Fuse Type Code No FuseSelf test Self TestMemory Clear This page is intentionally left blank Furuno Specifications of Interface Unit IF-NMEASC Jul.2307 R.Esumi Satellite Compass This page is intentionally left blank Page 00016689910