Furuno IF-NMEASC manual Heading, Pitch and Roll Offsets, Output Processing

Page 16

3. ADJUSTMENTS

3.3Heading, Pitch and Roll Offsets

Turn on the IF unit and wait approx. three minutes for the satellite compass to settle. Then, check that heading, pitch and roll data are reasonable. If not, open the unit and enter appropriate off- set(s).

1.Open the cover, referring to step 1 in the previous section for the procedure.

2.Open the inner cover.

On the circuit board, find the heading display, LED set, and operating buttons. The Heading LED is lit

When offset is minus

Offset

Port 2

Port 3

OUTPUT PROCESSING

0

3

Heading Pitch Roll

Sentence Bps Output

Interval

Sentence Bps Output

Interval

Use the [Menu/Cancel] button to show the heading indication. Push the [Enter] button to show the heading offset value.

Operating buttons

Menu/

Cancel

Enter

-

+

3.Push the [Menu/Cancel] button to light the applicable Offset LED (Heading, Pitch, or Roll) and push the [Enter] button. The selected LED starts flashing and the display shows current offset for item selected.

4.Use the [+] or [-] button to set offset. (You can push and hold down those buttons to speed up the rate of incrementation.)

Range of offset

Heading: ±6°

Pitch, Roll: ±10°

5.Push the [Enter] button to finish. The display shows current heading, pitch or roll indication with offset applied. The selected Offset LED stops flashing.

6.Close the inner and outer covers.

8

Image 16
Contents Model IF-NMEASC Page Important Notices Safety Instructions Safety instructions for the operatorIii Table of Contents Foreword Word to the Owner of the IF-NMEASCSystem Configuration Mounting Procedure MountingEquipment List Name Type Code No Qty RemarksWiring Cable construction LEDs and Equipment Status AdjustmentsLED state and equipment status Setting Up Nmea Ports Port no Sentence Baud rate bps Tx interval msOutput Processing Sentence Output interval ms Heading, Pitch and Roll Offsets Output ProcessingOperation Preventive Maintenance MAINTENANCE, TROUBLE- ShootingCheck point Remedy Troubleshooting Symptom Possible trouble RemedyReplacing the Fuse Type Code No FuseSelf Test Self testMemory Clear This page is intentionally left blank Furuno Specifications of Interface Unit IF-NMEASC Jul.2307 R.Esumi Satellite Compass This page is intentionally left blank Page 00016689910