Furuno manual Furuno Specifications of Interface Unit IF-NMEASC

Page 23

FURUNO

SPECIFICATIONS OF INTERFACE UNIT

IF-NMEASC

IF-NMEASC

1 INPUT PORT

NMEA 2000*, for data I/O between FURUNO satellite compass SC-30 * NMEA 2000 is a registered trademark of the Nationa l Marine Electronics Association.

2 OUTPUT PORT

NMEA 0183: Two ports (HDT, HDG, HMD, ATT*, HVE*, VTG, GGA, RMC, ZDA)

* ATT (heading, pitch, roll) and HVE (heave) are FURUNO proprietary sentences.

AD-10: One port

Analog: One port (pitch, roll)

3

NMEA 0183 OUTPUT INTERVAL

 

 

HDT, HDG, HDM, ATT, HVE: 25ms, 100 ms, 200 ms, 1 s, 2 s

 

 

VTG, GGA, RMC, ZDA: 1 s, 2 s

4

POWER SUPPLY

 

 

 

12-24 VDC: 1.0-0.6 A

5

ENVIRONMENTAL CONDITIONS

5.1

Ambient Temperature

-15°C to +55°C

5.2

Humidity

Less than 95% at 40°C

5.3

Waterproofing

IP20

5.4

Vibration

- From 2 Hz to 5 Hz to up to 13.2 Hz with an excursion of ±1 mm ±10%

 

 

-13.2 Hz to 100 Hz with a constant maximum acceleration of 7 m/s2

6

COATING COLOR

 

 

 

N2.5

SP - 1

E7265S02A-M

Image 23
Contents Model IF-NMEASC Page Important Notices Safety instructions for the operator Safety InstructionsIii Table of Contents Word to the Owner of the IF-NMEASC ForewordSystem Configuration Name Type Code No Qty Remarks Mounting ProcedureMounting Equipment ListWiring Cable construction LED state and equipment status AdjustmentsLEDs and Equipment Status Port no Sentence Baud rate bps Tx interval ms Setting Up Nmea PortsOutput Processing Sentence Output interval ms Output Processing Heading, Pitch and Roll OffsetsOperation Check point Remedy MAINTENANCE, TROUBLE- ShootingPreventive Maintenance Type Code No Fuse TroubleshootingSymptom Possible trouble Remedy Replacing the FuseSelf test Self TestMemory Clear This page is intentionally left blank Furuno Specifications of Interface Unit IF-NMEASC Jul.2307 R.Esumi Satellite Compass This page is intentionally left blank Page 00016689910