Datalogic Scanning DS4300 manual Picket Fence Mode, Sn = Fw-Lw/Ls * Ss

Page 45

DS4300

DATALOGIC

For example, the DS4300 (800 scans/sec.), for a 25 mm high code moving at 1250 mm/s performs:

[(25/1250) * 800] - 2 = 14 effective scans.

3.2.2 Picket Fence Mode

Laser Beam

Code motion

moving at LS speed

DS4300LW

FW

Figure 3.6 - "Picket Fence" scanning mode

If scanning is parallel to the code motion, (Figure 3.6 - "picket fence" mode), the number of effective scans is given by:

SN = [((FW-LW)/LS) * SS] - 2

These symbols signify:

SN = number of effective scans

FW = reading field width (in mm)

LW = label width (in mm)

LS = label movement speed (in mm/s)

SS = scans per second

For example, for a 100 mm wide code moving in a point where the reading field is 200 mm wide at a 2000 mm/s speed, the DS4300 (800 scans per sec.), performs:

[((200-100)/2000) * 800] - 2 = 38 scans

3.4- Reading Features

Image 45
Contents Page DS4300 Installation ManualDS4300-XXXX, Laser Scanner and all its models Datalogic S.p.AContents Maintenance Guide to Installation General View DS4300Figure B Safety Precautions Laser SafetyStandard Regulations Laser diode class label Power Supply Introduction General FeaturesStandard Application Program ProgrammabilityDescription Red, indicates the reader is connected to the power supply Accessories Available ModelsDS4300 Package Contents InstallationOverall dimensions Mechanical InstallationJunction Box Mounting Junction BOX InstallationJunction box mounting System cable connections to the junction box Junction Box Electrical ConnectionsPin RS232 RS485 MA CL Full-duplex BOX pinout for DS4300 Pin NameScanner cable connections to the junction box Electrical Connections for 25-PIN Models Pin D-sub connector pinout Name FunctionDS4300 Power SupplyRS232 Main Serial InterfaceRS232 Pin Name Function13 RS232 main interface connections 15 RS485 full-duplex connections RS485 Full-DuplexMultiplexer RS485 Half-DuplexChassis Clin MA Current Loop INT-24 Accessory OnlyInputs Auxiliary RS232 InterfaceEXT TRIG+ 22 Input PNP command using external power 24 Open collector output connection Outputs25 Pitch angle PositioningPoint-to-Point Typical LayoutsDS4300 Host Main serial interface Pass Through30 RS232 Master/Slave layout 3 RS232 Master/SlaveHost 4 RS485 Master/Slave32 Multiplexer layout MultiplexerThis page is intentionally left blank Installation Advanced Code Reconstruction Reading FeaturesTilt angle Tilt Angle for Advanced Code ReconstructionDecoding Capacity in Linear Mode Step Ladder ModeSN = LH/LS * SS SN = FW-LW/LS * SS Picket Fence ModePerformance DS4300-100X Code Resolution Standard Reading DiagramsCode Resolution High DS4300-100X Code Resolution HighThis page is intentionally left blank Reading Features Cleaning MaintenanceThis page is intentionally left blank Maintenance Reading Features Note Technical FeaturesSoftware Features