Datalogic Scanning DS4300 manual Software Features

Page 53

DS4300DATALOGIC

SOFTWARE FEATURES

READABLE CODE SYMBOLOGIES

EAN/UPC

Code 93

2/5 Interleaved

Code 128

Code 39

EAN 128

Codabar

Pharmacode

 

 

CODE SELECTION

up to six codes during one reading phase

 

 

DECODING SAFETY

can enable multiple good reads of same code

 

 

HEADERS AND TERMINATORS

up to four headers and four terminators

 

 

OPERATING MODES

ON LINE, AUTOMATIC, SERIAL ON LINE, TEST

 

 

CONFIGURATION MODES

through menus using WinHost utility

 

 

 

 

 

receiving commands from one of the serial

 

 

ports (HOST MODE)

 

 

PARAMETER STORAGE

Non-volatile internal memory

 

 

 

ENVIRONMENTAL FEATURES

 

 

 

 

Operating temperature (Note 3)

0 to 40 ° C (32 to 104 °F)

Storage temperature

-20

to 70 ° C (-4 to 158 °F)

Humidity max.

90% non condensing

Vibration resistance

IEC 68-2-6 test FC 1.5 mm;

 

 

10 to 55 Hz; 2 hours on each axis

Shock resistance

IEC 68-2-27 test EA 30G;

 

 

11 ms; 3 shocks on each axis

Protection class

IP65

 

 

 

PHYSICAL FEATURES

 

 

Mechanical dimensions

101 x 83.5 x 42 mm (3.97 x 3.29 x 1.65 in.)

Weight

about 800 g. (28.2 oz.)

 

 

 

 

Note 1: The features given are typical at a 25 ° C ambient temperature (if not otherwise indicated).

Note 2: Further details given in paragraphs 3.3 and 3.4.

Note 3: If the reader is used in high temperature environments (over 35 ° C), use of the Beam shutter is advised (for details refer to the WinHost Help On Line).

5.2– Technical Features

Image 53
Contents Page DS4300 Installation ManualDS4300-XXXX, Laser Scanner and all its models Datalogic S.p.AContents Maintenance Guide to Installation General View DS4300Figure B Standard Regulations Safety PrecautionsLaser Safety Laser diode class label Power Supply Introduction General FeaturesStandard Application Program ProgrammabilityDescription Red, indicates the reader is connected to the power supply DS4300 AccessoriesAvailable Models Package Contents InstallationOverall dimensions Mechanical InstallationJunction Box Mounting Junction BOX InstallationJunction box mounting System cable connections to the junction box Junction Box Electrical ConnectionsPin RS232 RS485 MA CL Full-duplex BOX pinout for DS4300 Pin NameScanner cable connections to the junction box Electrical Connections for 25-PIN Models Pin D-sub connector pinout Name FunctionDS4300 Power SupplyRS232 Main Serial InterfaceRS232 Pin Name Function13 RS232 main interface connections 15 RS485 full-duplex connections RS485 Full-DuplexMultiplexer RS485 Half-DuplexChassis Clin MA Current Loop INT-24 Accessory OnlyInputs Auxiliary RS232 InterfaceEXT TRIG+ 22 Input PNP command using external power 24 Open collector output connection Outputs25 Pitch angle PositioningPoint-to-Point Typical LayoutsDS4300 Host Main serial interface Pass Through30 RS232 Master/Slave layout 3 RS232 Master/SlaveHost 4 RS485 Master/Slave32 Multiplexer layout MultiplexerThis page is intentionally left blank Installation Advanced Code Reconstruction Reading FeaturesTilt angle Tilt Angle for Advanced Code ReconstructionSN = LH/LS * SS Decoding Capacity in Linear ModeStep Ladder Mode SN = FW-LW/LS * SS Picket Fence ModePerformance DS4300-100X Code Resolution Standard Reading DiagramsCode Resolution High DS4300-100X Code Resolution HighThis page is intentionally left blank Reading Features Cleaning MaintenanceThis page is intentionally left blank Maintenance Reading Features Note Technical FeaturesSoftware Features