Datalogic Scanning DS4300 manual Main Serial Interface, RS232, Pin Name Function

Page 25

DS4300

DATALOGIC

2.4.2 Main Serial Interface

The signals relative to the following serial interface types are available on the input/output connector:

RS232

RS485 FULL DUPLEX

RS485 HALF DUPLEX

An active 20-mA Current Loop interface is available if the optional INT-24 accessory is installed. This accessory interface replaces the RS232/RS485 selections.

The main serial interface type and its relative parameters (baud rate, data bits, etc.) are selected via software either using the WinHost utility program or Host Mode programming. For more details refer to the section "Main Interface Menu" in the WinHost Help On Line.

Details regarding the connections and use of the main interface selection are given in the next paragraphs.

RS232

The serial interface is used in this case for point-to-point connections; it handles communication with the host computer and allows both transmission of code data and the configuration of the scanner. This is the default interface.

The following pins of the 25-pin connector are used for RS232 interface connection:

Pin

Name

Function

 

 

 

2

TX232

transmitted data

3

RX232

received data

4

RTS232

request to send

5

CTS232

clear to send

7

SGND Main

signal ground main interface

2.10- Installation

Image 25
Contents Page DS4300 Installation ManualDS4300-XXXX, Laser Scanner and all its models Datalogic S.p.AContents Maintenance Guide to Installation General View DS4300Figure B Laser Safety Safety PrecautionsStandard Regulations Laser diode class label Power Supply Introduction General FeaturesStandard Application Program ProgrammabilityDescription Red, indicates the reader is connected to the power supply Available Models AccessoriesDS4300 Package Contents InstallationOverall dimensions Mechanical InstallationJunction Box Mounting Junction BOX InstallationJunction box mounting System cable connections to the junction box Junction Box Electrical ConnectionsPin RS232 RS485 MA CL Full-duplex BOX pinout for DS4300 Pin Name Scanner cable connections to the junction box Electrical Connections for 25-PIN Models Pin D-sub connector pinout Name FunctionDS4300 Power SupplyRS232 Main Serial InterfaceRS232 Pin Name Function13 RS232 main interface connections 15 RS485 full-duplex connections RS485 Full-DuplexMultiplexer RS485 Half-DuplexChassis Clin MA Current Loop INT-24 Accessory OnlyInputs Auxiliary RS232 InterfaceEXT TRIG+ 22 Input PNP command using external power 24 Open collector output connection Outputs25 Pitch angle PositioningPoint-to-Point Typical LayoutsDS4300 Host Main serial interface Pass Through30 RS232 Master/Slave layout 3 RS232 Master/SlaveHost 4 RS485 Master/Slave32 Multiplexer layout MultiplexerThis page is intentionally left blank Installation Advanced Code Reconstruction Reading FeaturesTilt angle Tilt Angle for Advanced Code ReconstructionStep Ladder Mode Decoding Capacity in Linear ModeSN = LH/LS * SS SN = FW-LW/LS * SS Picket Fence ModePerformance DS4300-100X Code Resolution Standard Reading DiagramsCode Resolution High DS4300-100X Code Resolution HighThis page is intentionally left blank Reading Features Cleaning MaintenanceThis page is intentionally left blank Maintenance Reading Features Note Technical FeaturesSoftware Features