Datalogic Scanning DS4300 manual 4 RS485 Master/Slave, Host

Page 39

DS4300

DATALOGIC

2.6.4 RS485 Master/Slave

The RS485 master/slave connection is used to collect data from several scanners to build either an omni-directional or a multi-sided reading system; there can be one master and up to 5 slaves connected together.

The Slave scanners are connected together using RS485 half-duplex on the main serial interface. Every Slave scanner must have a multidrop address in the range 0-4.

The Master scanner is also connected to the Host on the RS232 auxiliary serial interface.

The External Trigger signal is unique to the system; there is a single reading phase and a single message from the master scanner to the Host computer.

It is necessary to bring the External Trigger signal to all the scanners.

The main and auxiliary ports are connected as shown in the figure below.

DS4300 Slave

1

DS4300

Slave

2

1

 

3

* Master

1

 

Host

1

Auxiliary serial interface

 

2

RS485 HD Main serial interface

 

3

External Trigger

 

Figure 2.31 - RS485 Master/Slave layout

*DS4300 cannot be used as the Master in the RS485 Master/Slave layout. For a list of Master compatible scanners see the Guide to Rapid configuration in the WinHost Help On Line.

2.24- Installation

Image 39
Contents Page DS4300 Installation ManualDS4300-XXXX, Laser Scanner and all its models Datalogic S.p.AContents Maintenance Guide to Installation General View DS4300Figure B Safety Precautions Laser SafetyStandard Regulations Laser diode class label Power Supply Programmability General FeaturesIntroduction Standard Application ProgramDescription Red, indicates the reader is connected to the power supply Accessories Available ModelsDS4300 Package Contents InstallationOverall dimensions Mechanical InstallationJunction Box Mounting Junction BOX InstallationJunction box mounting System cable connections to the junction box Junction Box Electrical ConnectionsPin RS232 RS485 MA CL Full-duplex BOX pinout for DS4300 Pin NameScanner cable connections to the junction box Electrical Connections for 25-PIN Models Pin D-sub connector pinout Name FunctionDS4300 Power SupplyPin Name Function Main Serial InterfaceRS232 RS23213 RS232 main interface connections 15 RS485 full-duplex connections RS485 Full-DuplexMultiplexer RS485 Half-DuplexChassis Clin MA Current Loop INT-24 Accessory OnlyInputs Auxiliary RS232 InterfaceEXT TRIG+ 22 Input PNP command using external power 24 Open collector output connection Outputs25 Pitch angle PositioningPoint-to-Point Typical LayoutsDS4300 Host Main serial interface Pass Through30 RS232 Master/Slave layout 3 RS232 Master/SlaveHost 4 RS485 Master/Slave32 Multiplexer layout MultiplexerThis page is intentionally left blank Installation Advanced Code Reconstruction Reading FeaturesTilt angle Tilt Angle for Advanced Code ReconstructionDecoding Capacity in Linear Mode Step Ladder ModeSN = LH/LS * SS SN = FW-LW/LS * SS Picket Fence ModePerformance DS4300-100X Code Resolution Standard Reading DiagramsCode Resolution High DS4300-100X Code Resolution HighThis page is intentionally left blank Reading Features Cleaning MaintenanceThis page is intentionally left blank Maintenance Reading Features Note Technical FeaturesSoftware Features