Blade ICE G8000 manual Typographic Conventions

Page 13

RackSwitch G8000 Application Guide

Typographic Conventions

The following table describes the typographic styles used in this book.

Table 1 Typographic Conventions

Typeface or

Meaning

Example

Symbol

 

 

 

 

 

AaBbCc123

This type is used for names of commands,

View the readme.txt file.

 

files, and directories used within the text.

 

 

It also depicts on-screen computer output and

Main#

 

prompts.

 

 

 

 

AaBbCc123

This bold type appears in command exam-

Main# sys

 

ples. It shows text that must be typed in

 

 

exactly as shown.

 

<AaBbCc123> This italicized type appears in command examples as a parameter placeholder. Replace the indicated text with the appropriate real name or value when using the command. Do not type the brackets.

To establish a Telnet session, enter: host# telnet <IP address>

 

This also shows book titles, special terms, or

Read your User’s Guide thoroughly.

 

words to be emphasized.

 

 

 

 

[ ]

Command items shown inside brackets are

host# ls [-a]

 

optional and can be used or excluded as the

 

 

situation demands. Do not type the brackets.

 

 

 

 

BMD00041, November 2008

Preface „ 13

Image 13
Contents Application Guide RackSwitch G8000 Application Guide Contents Ports and Trunking Quality of Service Appendix a Troubleshooting Figures RackSwitch G8000 Application Guide Tables RackSwitch G8000 Application Guide Who Should Use This Guide PrefaceWhat You’ll Find in This Guide Typographic Conventions Typographic ConventionsHow to Get Help Accessing the Switch Log on to the switch Enter IP interface mode Configuring an IP InterfaceConfigure the default gateway. Enable the gateway Using Telnet Configuring BBI access via Http Using the Browser-Based InterfaceConfiguring BBI access via Https RS G8000 config# access https import-certificate Default configuration Using SnmpSnmp v1 SnmpPrivacy-password User configuration22 „ Accessing the Switch SNMPv2 trap host configuration Configuring Snmp Trap HostsConfigure an entry in the notify table SNMPv1 trap hostSNMPv3 trap host configuration Securing Access to the Switch How Radius authentication works Radius Authentication and AuthorizationConfigure the Radius secret and enable the feature Configuring RadiusRadius authentication features in Blade OS Radius Attributes for G8000 user privileges Switch User AccountsHow TACACS+ authentication works TACACS+ AuthenticationAuthorization TACACS+ authentication features in Blade OSAccounting Command authorization and loggingConfigure the TACACS+ secret and second secret Configuring TACACS+ AuthenticationSecure Shell Configuring SSH features on the switchSSH encryption of management messages SSH Integration with RADIUS/TACACS+ Authentication Generating RSA Host and Server Keys for SSH accessConsiderations for configuring End User Accounts End User Access ControlUser Access Control Logging into an End User account Listing current UsersRackSwitch G8000 Application Guide 38 „ Accessing the Switch Port-based Network Access Control Extensible Authentication Protocol over LAN Port Unauthorized 802.1X authentication processEAPoL message exchange „ Unauthorized 802.1X port states„ Authorized „ Force UnauthorizedSupport for Radius Attributes Supported Radius attributesConfiguration guidelines BMD00041, November VLANs Overview Vlan numbers VLANs and Port Vlan ID NumbersViewing VLANs Pvid numbers Viewing and Configuring PVIDsVlan Tagging 1Default Vlan settings 2Port-based Vlan assignment 4802.1Q tag assignment Vlan Topologies and Design Considerations Vlan configuration rulesComponent Description Multiple VLANs with Tagging AdaptersVlan Enable tagging on uplink ports that support multiple VLANs Vlan configuration exampleConfigure the VLANs and their member ports Private Vlan ports Private VLANsSelect a Vlan and define the Private Vlan type as primary Configuration exampleVerify the configuration Configure a secondary Vlan and map it to the primary VlanRackSwitch G8000 Application Guide 62 „ VLANs Ports and Trunking Statistical load distribution Built-In fault toleranceStatic trunk group configuration rules Before you configure static trunks66 „ Ports and Trunking Follow these steps on the G8000 Port Trunking ExampleExamine the trunking information on each switch Repeat the process on the other switch„ Source IP SIP + Destination IP DIP Configurable Trunk Hash AlgorithmLink Aggregation Control Protocol Admin keyRS G8000 # show lacp information Configuring Lacp Lacp configuration guidelinesSet the Lacp mode Spanning Tree 1Ports, Trunk Groups, and VLANs Determining the Path for Forwarding BPDUs Bridge Protocol Data Units BPDUsChanging the Spanning Tree mode Spanning Tree Group configuration guidelinesAssigning a Vlan to a Spanning Tree Group Rules for Vlan Tagged ports Creating a VlanAdding and removing ports from STGs RackSwitch G8000 Application Guide Port state changes Rapid Spanning Tree ProtocolPort Type and Link Type Rstp configuration guidelinesEdge Port Link TypeConfigure Rapid Spanning Tree Rstp configuration examplePer Vlan Rapid Spanning Tree Default Spanning Tree configuration1Two VLANs on one Spanning Tree Group Why do we need multiple Spanning Trees?Configuring Pvrst Pvrst configuration guidelinesSet the Spanning-tree mode to PVRST+ Mstp Region Multiple Spanning Tree ProtocolCommon Internal Spanning Tree Mstp configuration guidelines Passing Vlan Blocking Vlan Configure Multiple Spanning Tree Protocol Configuring Multiple Spanning Tree Groups90 „ Spanning Tree Fast Uplink Convergence Configuring Fast Uplink ConvergenceRackSwitch G8000 Application Guide 92 „ Spanning Tree Quality of Service COS MAC Extended ACLs Using ACL FiltersIP Extended ACLs IP Standard ACLs1Well-known protocol types Assigning ACLs to a port Understanding ACL priorityViewing ACL statistics Use the following command to view ACL statisticsConfigure an Access Control List ACL configuration examplesExample Assign the ACL to port100.10.1.0 Add the ACL to a port Add the ACL to portConfigure a MAC ACL to deny all other traffic Configure IP ACLs to deny all other trafficAssign the ACLs to a port Configuring storm control Using Storm Control FiltersBroadcast storms Differentiated Services Concepts Using Dscp Values to Provide QoSRackSwitch G8000 Application Guide Drop Class Precedence Per Hop BehaviorQoS Levels Default QoS Service LevelsDSCP-to-802.1p mapping Use the following command to perform DSCP-to-802.1p mapping3Layer 2 802.1q/802.1p Vlan tagged packet Using 802.1p Priority to Provide QoSConfigure a port’s default 802.1p priority value to 802.1p configuration exampleQueuing and Scheduling Overview Remote MonitoringEnable Rmon on a port Configuring Rmon statisticsConfigure the Rmon statistics on a port Rmon group 1-StatisticsHistory MIB Object ID Rmon group 2-HistoryConfiguring Rmon History Rmon group 3-AlarmsConfigure the Rmon History parameters for a port View Rmon History for the portConfiguring Rmon Alarms Alarm MIB objectsConfigure the Rmon Alarm parameters to track Icmp messages Configure Rmon eventsConfigure the Rmon event parameters Rmon group 9-EventsBasic IP Routing IP Routing Benefits 1The Router Legacy Network Routing Between IP Subnets122 „ Basic IP Routing Example of Subnet Routing 2Switch-Based Routing Topology1Subnet Routing Example IP Address Assignments Using VLANs to segregate Broadcast Domains3Subnet Routing Example Optional Vlan Ports Add the switch ports to their respective VLANsEnable IP routing Configure the default gateway to the routers’ addressesAssign a Vlan to each IP interface Dynamic Host Configuration Protocol RackSwitch G8000 Application Guide 128 „ Basic IP Routing Igmp Igmp Snooping IGMPv3 Snooping FastLeaveConfigure Igmp Snooping Igmp Snooping configuration exampleEnable IGMPv3 Snooping optional Add VLANs to Igmp SnoopingRS G8000# show ip igmp groups View dynamic Igmp informationStatic Multicast Router Configure a Static Multicast RouterHigh Availability 1Uplink Failure Detection example Uplink Failure DetectionFailure Detection Pair Spanning Tree Protocol with UFD Configuration guidelinesMonitoring UFD Configuring UFDTurn on Uplink Failure Detection UFD Troubleshooting Figure A-1Monitoring Ports Monitoring PortsEnable port mirroring Configuring Port MirroringView the current configuration Port Mirroring behaviorBMD00041, November Numerics IndexIgmp TACACS+
Related manuals
Manual 28 pages 31.53 Kb