Use one of the following commands to correlate an Alarm index to an Event index:
RS G8000 (config)# rmon alarm <alarm number>
When the alarm threshold is reached, the corresponding event is triggered.
Alarm MIB objects
The most common data types used for alarm monitoring are ifStats: errors, drops, bad CRCs, and so on. These MIB Object Identifiers (OIDs) correlate to the ones tracked by the History Group. The following are examples of RMON statistics:
1.3.6.1.2.1.5.1.0– mgmt.icmp.icmpInMsgs
1.3.6.1.2.1.2.2.1.10.x – ifInOctets
The last digit (x) represents the interface on which to monitor, which corresponds to the inter- face number, or port number, as follows:
129 = port 1
130 = port 2
…
172 = port 44
This value represents the alarm’s MIB OID, as a string. Note that for
Configuring RMON Alarms
Example 1
1.Configure the RMON Alarm parameters to track the number of packets received on port 1.
RS G8000 (config)# rmon alarm 1 oid 1.3.6.1.2.1.2.2.1.10.129
RS G8000 (config)# rmon alarm 1
RS G8000 (config)# rmon alarm 1
This configuration creates an RMON alarm that checks ifInOctets on port 1 once every hour. If the statistic exceeds two billion, an alarm is generated that triggers event index 100.