| RackSwitch G8000 Application Guide |
|
|
Component | Description |
|
|
Server 1 | This server is a member of VLAN 1 and has presence in only one IP |
| subnet. The associated switch port is only a member of VLAN 1, so |
| tagging is disabled. |
|
|
Server 2 | This server is a member of VLAN 1 and has presence in only one IP |
| subnet. The associated switch port is only a member of VLAN 1, so |
| tagging is disabled. |
|
|
Server 3 | This server belongs to VLAN 2, and it is logically in the same IP sub- |
| net as Server 5. |
| The associated switch port has tagging disabled. |
|
|
Server 4 | A member of VLAN 3, this server can communicate only with other |
| servers via a router. |
| The associated switch port has tagging disabled. |
|
|
Server 5 | A member of VLAN 1 and VLAN 2, this server can communicate only |
| with Server 1, Server 2, and Server 3. |
| The associated switch port has tagging enabled. |
|
|
Enterprise | These switches must have all three VLANs (VLAN 1, 2, 3) configured. |
Routing switches | They can communicate with Server 1, Server 2, and Server 5 via |
| VLAN 1. |
| They can communicate with Server 3 and Server 5 via VLAN 2. |
| They can communicate with Server 4 via VLAN 3. |
| Tagging on switch ports is enabled. |
|
|
NOTE – VLAN tagging is required only on ports that are connected to other switches or on ports that connect to
BMD00041, November 2008 | Chapter 3: VLANs 57 |