Cyclades PC400 installation manual ISDN-PRI Profile Parameters

Page 16

Parameters that define customized ISDN-PRI profiles.

Label

Description

cnx_profile_begin

Up to 5 different ranges for cnx_profile can be configured.

phone

The first phone number of the range with this profile. It should not exceed 30 characters

 

and "none" specifies the null string.

size_range

The number of phone numbers in the range with this profile. Values range from 1 to 255.

 

No label is equivalent to the value 0.

cnx_type

Type of incoming call. Possible values are analog, digital, v110, v120 or a combination

 

of the four separated by the pipe, "".

cnx_profile_end

ends definition of customized ISDN-PRI profile.

 

FIG. 4.2 ISDN-PRI PROFILE PARAMETERS

Parameters that define and apply to DSP profiles.

Label

Description

dsp_profile_begin

Marks the beginning of a digital signal processor profile. All parameters following this

 

label apply only to this dsp profile until dsp_profile_end is reached.

profile_id

A number between 1 and 5 which labels the dsp profile for later reference.

config_string

Commands sent to the dsp. It should not exceed 80 characters.

dsp_profile_end

Marks the end of the configuration parameters for a digital signal processor profile. See

 

comments for dsp_profile_begin above.

 

FIG. 4.3 DSP PROFILE PARAMETERS

Chapter 4 Board and System Configuration

16

Image 16
Contents Cyclades-PC400 FCC Warning Statement Cyclades-PC400 Installation ManualCanadian DOC Notice Table of Contents Appendix B Hardware Specifications What is in the BOX Upgrades of Software and ManualsStep One Hardware InstallationStep Two Step Three Step Four Step FiveSoftware Installation Software Installation Make config Make menuconfig Step ONE Board and System ConfigurationStep TWO Dspprofilebegin InterfnNbegin Label Description ISDN-PRI Profile Parameters Interface Parameters USA AT&T Last or channelnumberchannelnumberchannelnumber etc Pc400loadPc400util -p Step ThreeStep Four Step Five Guided Examples for the Most Common ApplicationsLAN ISDN-BRIParameter Description Value for T1 Value for E1 Line RAS DIAL-IN Application Parameters∙∙∙ LAN Example 2 a LAN-to-LAN Example Using ChannelsETH0 10 Multiple LAN-TO-LAN Application Parameters ∙∙∙ Troubleshooting General TipsHardware Test Root@cyclades common# ./pc400hwtestESC Previous Menu G Global E Errors Global TestPasses Pg0 Board DSP U19 U06 U20 U07Previous Menu G Global E Errors ESCAdministrative Utilities Users and Passwords Appendix a Information for Users not Familiar with LinuxPasswd Linux File StructureBasic File Manipulation Commands Cp filename destinationVi Editor Mode What is done there How to Get ThereVi filename Routing Table Netstat -rn Net-hostNetmask Ssh The Secure Shell SessionLoading the Configuration File PID TTY Stat Time CommandProcess Table Minute hour date month day-of-week user command Get information from the boardSyslog Crond UtilityActive root /etc/tstcron.src Dhcp Dynamic Host Configuration Protocol Client59 * * * * /etc/testcron.sh Packet Filtering using ipchains Accept Deny Interface isCyclades-PC400 Installation Manual Appendix B Hardware Specifications RJ-48C Signal Pin RxTip RxRing TxTip TxRingCyclades Philippines