Cyclades PC400 installation manual Hardware Test, Root@cyclades common# ./pc400hwtest

Page 29

Cyclades-PC400

Installation Manual

Hardware Test

A menu-driven hardware test called pc400hwtest is included with the Cyclades-PC400 driver. It is executed by typing pc400hwtest at the command line. Note that the PC400 should not be tested while in use as the test will inactivate all ports. First, RAM integrity is checked:

[root@cyclades common]# ./pc400hwtest

Please wait while program is examining the hardware BOARD[1] RAM TEST ED000000, PCI ED926000 OK !

Press [enter] to continue.

Application Checking Firmware Integrity (CRC) ... OK

Then press the <ENTER> key to bring up the main screen, shown below:

PC400HWTest/Linux

Revision 2.0.0 (2001/12/12)

1.Test Asynchronous Ports

2.Test T1 Channelized Ports

3.Test E1 DSP Ports

4.Quit

Select option ==>

Chapter 5 Troubleshooting

29

Image 29
Contents Cyclades-PC400 Canadian DOC Notice Cyclades-PC400 Installation ManualFCC Warning Statement Table of Contents Appendix B Hardware Specifications Upgrades of Software and Manuals What is in the BOXStep Two Hardware InstallationStep One Step Three Step Five Step FourSoftware Installation Software Installation Make config Make menuconfig Step TWO Board and System ConfigurationStep ONE Dspprofilebegin InterfnNbegin Label Description ISDN-PRI Profile Parameters Interface Parameters USA AT&T Pc400load Last or channelnumberchannelnumberchannelnumber etcPc400util -p Step ThreeStep Four Guided Examples for the Most Common Applications Step FiveISDN-BRI LANRAS DIAL-IN Application Parameters Parameter Description Value for T1 Value for E1 Line∙∙∙ ETH0 Example 2 a LAN-to-LAN Example Using ChannelsLAN 10 Multiple LAN-TO-LAN Application Parameters ∙∙∙ General Tips TroubleshootingRoot@cyclades common# ./pc400hwtest Hardware TestGlobal Test ESC Previous Menu G Global E ErrorsPasses Pg0 Board DSP U19 U06 U20 U07ESC Previous Menu G Global E ErrorsAdministrative Utilities Appendix a Information for Users not Familiar with Linux Users and PasswordsPasswd Linux File StructureCp filename destination Basic File Manipulation CommandsVi filename Mode What is done there How to Get ThereVi Editor Routing Table Net-host Netstat -rnNetmask Ssh The Secure Shell SessionProcess Table PID TTY Stat Time CommandLoading the Configuration File Get information from the board Minute hour date month day-of-week user commandSyslog Crond Utility59 * * * * /etc/testcron.sh Dhcp Dynamic Host Configuration Protocol ClientActive root /etc/tstcron.src Packet Filtering using ipchains Interface is Accept DenyCyclades-PC400 Installation Manual RJ-48C Signal Pin RxTip RxRing TxTip TxRing Appendix B Hardware SpecificationsCyclades Philippines