Multi Tech Equipment MT5634ZBA-V-V92 manual 104

Page 101

MultiModemZBA-V-V92 User Guide

Index

 

 

programs, communication 12 Protocol Result Code command 28 protocols 78

Pulse Dialing command 23

Q

Quick Connect 17, 36

Quick Connect Control command 36

R

rate, maximum data 41

Read Register Value command 23 registering your product 99 remote configuration 47–48

escape character 40, 48 escape sequence 39

remote node operation 18 removing a modem from Windows

10

Repeat command 21 replacement parts 100 required equipment 3 resetting the modem 24, 25 Result Code Format command 24 Result Code Options command 24 Result Code Selection command

24

result codes 20, 28, 43–44, 76 Result Codes Enable/Disable

command 23 Return Online to Data Mode

command 23

rings, setting number of 12, 40 ROM checksum 22

RS-232 connection 8

S

S-registers40–44 reading 23 S000 12, 40 S001 40 S002 40 S003 40 S004 40 S005 40 S006 40 S007 40 S008 40

S009 40, 48

S010 40

S011 40

S018 40

S028 40

S030 40

S035 40

S036 41

S037 41

S038 41

S042 42

S048 42

S089 42

S108 42 setting 23

safety 5

Select Maximum MNP Block Size command 26

Select V.44 Data Compression command 31

serial cable 75

serial port 12, 30, 75, 76

Serial Port Baud Rate command 30 servicing your modem 81

Set 11-bit Parity command 39 Set Register Value command 23 software, communication 12 solving problems 74–79 Speaker Mode command 23 specifications, technical 86–87 speed

maximum 41 serial port 12, 30

speed conversion (data buffer) 25 standby mode delay time 42 static electricity 6

Store Callback Password command 38, 63

Store Current Configuration

command 12, 26

Store Dialing Command 26, 65 Store Setup Password command

39, 64 surge protector 10

Sync/Async Mode command 78 synchronous buffered mode 32

T

technical specifications 86–87 telephone

connection 8 line 76

terminal mode 75

testing the modem 10, 26, 76 fax 18

self-test 74

Tone Dialing command 24 tones, dialing 40

Transmit Break command 27 troubleshooting 74–79

U

uninstalling a modem from Windows 10

upgrading the modem 88–90 upstream mode 35

V

V.22 mode 21

V.22bis Guard Tone Control command 25

V.25 data calling tone 29, 40

V.34 modulation, enabling 40

V.42 error correction 28 V.42bis data compression 29 V.44 data compression 31

V.44 Data Compression command

31

V.44 Data Compression Reporting command 31

V.54 tests 26

V.92 mode

17, 33, 34, 35, 36, 68–72

V.92 Modem Hook Flash command

35

video 32

View Numbers in Blacklist command 29

W

wait time for dial tone 40 warranty 81

Windows 9x 75

Windows NT 75

Windows operating systems 10

X

Xmodem 78

XON/XOFF Pacing Control

command 25

XON/XOFF Pass-Through

command 28

Y

Ymodem/G protocol 78

Z

Zmodem protocol 78

104

Image 101
Contents MT5634ZBA-V-V92 Record of Revisions Table of Contents AT Commands, S-Registers, and Result Codes Introduction Upgrade Overview Chapter Introduction MultiModemZBA-V-V92 User Guide Introduction Product DescriptionYou Supply We SupplyChapter Installation Mount the Feet Safety WarningsMultiModemZBA-V-V92 User Guide Installation Opening the Modem Change the Internal JumpersLocation of the Jumpers MultiModemZBA-V-V92 User Guide2 InstallationChanging the Dial-Up/Leased-Line Jumpers Changing the Voice JumperConnect the Modem to Your System Connect the Two-Wire Leased LineConnect the Modem to You PC Connect the Modem to the Telephone LineConnect the Modem to a Phone Optional Connect the Modem to the AC Power OutletConnect a Microphone and/or Speakers Optional Connect the MicrophonePower-On Test Install the Modem DriverInstalling the Modem Driver Surge Protectors and LightningUsing the Global Wizard to Configure Your Modem Configure the Modem for Your CountryUsing AT Commands to Configure Your Modem Click Initial Setup and Country SelectionInstall and Configure Your Software Chapter Operation MultiModemZBA-V-V92 User Guide Operation Front PanelPhoneTools Features Configuring the ModemLeased Line Operation SetupOperation Connecting to the InternetSending a Fax Dial-Up NetworkingChapter ATCommands,S-Registers,and ResultCodes Repeat Last Command AT CommandsCommunication Standard Setting AnswerNumber ATDT1028806127853500$123456789 Echo Command Mode CharactersDS=n Dial Stored Telephone Number Echo Online Data CharactersReturn Online to Data Mode Monitor Speaker ModeResult Codes Enable/Disable Modulation HandshakeTone Dialing Modem ResetResult Code Format Result Code OptionsAsynchronous Communications Mode Load Factory SettingsData Terminal Ready DTR Control XON/XOFF Pacing ControlDisplay Current Settings Test CommandsStore Current Configuration Store Dialing Command\Kn Break Control \Bn Transmit Break\Tn Inactivity Timer \Nn Error Correction Mode Selection\Qn Flow Control Selection \V n Protocol Result CodeDC n AT Command Control Adaptive Answer Result Code EnableData Calling Tone View Numbers in BlacklistCisco Configuration Direct Connect EnableCommand Speed Response $Dn DTR DialingData Compression Reporting Command +DCS=x,y Select V.44 Data CompressionCommand +DS44=n V.44 Data Compression Subparameters Enable Synchronous Buffered ModeMod Modulation SelectionMod value Valid maxrate values bps Command +PCW= n Call Waiting EnableCommand +PMHR=n Modem on Hold Initiate Modem on Hold EnablePCM Upstream Ignore Modem Hook FlashS109 Command +PMHT=n Modem on Hold TimerQuick Connect Control Command +VDR=x, y Distinctive Ring Report Command +VCID=n Caller ID SelectionCommand #CBDn Callback Delay Callback AttemptsCommand #CBFR Callback Failed Attempts Reset Command #CBF? Callback Failed Attempts Display#CBIn Local Callback Inactivity Timer Command #CBNy=x Store Callback Password#S=x Store Setup Password #Sx Enter Setup PasswordCommand +++ATCR Escape Sequence Command %%%ATCR Remote Configuration Escape SequenceRegisters Value Rate S38S48 S42S89 S108Terse Verbose Description Result CodesBlacklist Full Remote Configuration Setup Basic ProcedureTo Change the Setup Password MultiModemZBA-V-V92 User Guide Remote ConfigurationTo Change the Remote Escape Character Callback Security MultiModemZBA-V-V92 User Guide Callback Security CallbackSecurityTo Set the Parity of the Callback Security Messages To Turn Callback Security On and OffTo Assign Callback Passwords and Phone Numbers Password-Only Callback Calling ProceduresPassword Number-Entry CallbackExtension-Entry Callback Command #CBD n Callback Delay Callback Security CommandsCommand #CBIn Local Callback Inactivity Timer #S= x Store Setup Password #S x Enter Setup PasswordDT, or DP. Example AT&Z0=+-ATM0D5551212,??? Command &Zy=+-x,???Store Dialing CommandMultiModemZBA-V-V92 User Guide6 Callback Security Callback Assignments FormModem on Hold Operation MultiModemZBA-V-V92 User Guide Modem on Hold Operation What Is Modem on Hold?Modem on Hold Program Disable Modem on Hold Modem on Hold SettingsEnable Modem on Hold Enable Caller IDExit MTMoh Check Modem StatusAbout MTMoh Answering a Voice Call Using Modem on HoldResuming a Data Call Solving Problems MultiModemZBA-V-V92 User Guide Solving Problems None of the Indicators LightModem Does Not Respond to Commands Modem Cannot Connect When Dialing Modem Disconnects While Online Data Is Being Lost Modem Cannot Connect When AnsweringFile Transfer Is Slower Than It Should Be Fax and Data Software Can’t Run at the Same Time There Are Garbage Characters on the MonitorModem Doesn’t Work with Caller ID Appendixes MultiModemZBA-V-V92 User Guide Regulatory Compliance FCC Part 68 TelecomFax Branding Statement FCC PartInternational Modem Restrictions Canadian Limitations NoticeIndustry Canada New Zealand Telecom Warning Notice EMC, Safety, and R&TTE Directive ComplianceSouth African Notice Error Correction MultiModemZBA-V-V92 User Guide Technical SpecificationsMode of Operation Intelligent FeaturesConnectors Command BufferDiagnostics IndicatorsIdentify the Modem Firmware Upgrade OverviewIntroduction Extract the Upgrade Files Download the Upgrade FileIdentify the Current Firmware Version Clear Your Stored ParametersRestore Your Parameters Upgrade the Modem’s FirmwareStandard Linux Serial Port Definitions InstallationUsing the Terminal Program Minicom to Verify Operation Select Dialup Configuration Tool Using the Modem to Call the InternetCalling the ISP Answering CallsConfigure the Modem for your Country Connecting to a Cisco Router Console PortConfigure for Callback Security in Direct Connect Mode MultiModemZBA-V-V92 User Guide Connecting to a Cisco RouterConsole Port Final Setup Signal RJ-45 pin DB-9 pin DB-25 pin Remote ConfigurationConsole Port Connections Cable Pin-outs and Cabling Guide Console ModemMultiModemZBA-V-V92 User Guide Connecting to a Cisco Router Repair Procedures for U.S. and Canadian Customers Multi-Tech Systems, Inc. Warranty & Repairs PoliciesWarranty Repair Procedures for International Distributors Canadian Customers Online Warranty Registration ServiceInternational Customers outside U.S.A. and Canada Attn Repairs, Serial #Technical Support Replacement PartsInternet Sites International DistributorsIndex Index MultiModemZBA-V-V92 User Guide Index 103104

MT5634ZBA-V-V92 specifications

The Multi Tech Equipment MT5634ZBA-V-V92 is a versatile and reliable modem designed for various data communication applications. As a part of the MultiTech line of products, this modem is engineered to provide seamless connectivity in both dial-up and broadband environments. Its robust feature set ensures compatibility with a wide array of devices, making it a great choice for businesses and individuals alike.

One of the main features of the MT5634ZBA-V-V92 is its ability to operate at V.92 speeds, allowing for data transmission rates of up to 56 Kbps. This makes it suitable for sending and receiving large amounts of data quickly, a significant advantage for businesses that require efficient communication. The modem is also backward compatible with previous V.90 technologies, ensuring that it can connect with older systems without any issues.

Another notable aspect of the MT5634ZBA-V-V92 is its built-in error correction and data compression capabilities. These technologies significantly enhance data integrity and transmission speed, resulting in fewer dropped connections and faster downloads. The modem uses state-of-the-art compression algorithms to optimize data flow, making it ideal for applications that require reliable and swift data exchange.

In terms of connectivity, the MT5634ZBA-V-V92 supports various interfaces, including RS-232, which allows for easy integration with a wide range of computer systems and other devices. Its flexibility in interfacing options makes it suitable for diverse environments, from industrial applications to home office setups.

The modem's design is also focused on user-friendliness. It comes equipped with LED indicators that provide real-time status updates on power, data transmission, and network connection, allowing users to monitor their connections effortlessly. Additionally, the device includes a simple installation process, which minimizes downtime and helps users get up and running quickly.

The MT5634ZBA-V-V92 is built to last, with a sturdy construction that ensures durability in demanding conditions. Its compact design allows for easy mounting and placement, making it an excellent choice for both stationary and mobile applications.

Overall, the Multi Tech Equipment MT5634ZBA-V-V92 is a powerful modem that merges speed, reliability, and flexibility. With its advanced features and technologies, it stands out as a dependable solution for anyone in need of high-performance data communication. Whether for business or personal use, this modem meets the connectivity needs of today's digital landscape with ease.