Multi Tech Equipment MT5634ZBA-V-V92 manual Identify the Current Firmware Version

Page 86

MultiModemZBA-V-V92 User Guide

C Upgrading the Modem’s Firmware

 

 

Step 2: Identify the Current Firmware Version

Identify the current version of the firmware at the Multi-Tech Web site. If your modem already has the current firmware, there is no need to update it.

1.Using your favorite Web browser, go to http://www.multitech.com/SUPPORT/MultiModemZBA/ firmware.asp.

2.Scroll down to your modem model number.

3.Look at the firmware version number for your modem.

4.If the firmware version number matches the firmware version number found in “Step 1: Identify the Modem Firmware,” you have the current firmware version and do not need to be update.

5.If the firmware version number is greater than the firmware version number found in “Step 1: Identify the Modem Firmware,” your modem has an older firmware version. Continue with “Step 3: Download the Upgrade File.”

Warning: The first digit of the new firmware must match the first digit of the old firmware, or the modem may not work properly. E.g., if your current firmware version is 4.16, replace it only with 4.xx firmware, not 6.xx firmware.

Step 3: Download the Upgrade File

1.If you are not already at the MultiModemZBA Firmware page of the Multi-Tech Web site, follow the procedure in “Step 2: Identify the Current Firmware.”

2.Download the upgrade file for your modem by clicking its name, and save the file in a temporary folder on your hard disk.

3.In the same section of the Web page, click the Flash Wizard utility for your operating system to download it, and save it in the same folder.

Step 4: Extract the Upgrade Files

1.Install the Flash Wizard utility by double-clicking the file name in Windows Explorer.

2.Extract the upgrade files by double-clicking the file name. The extracted files include a .HEX file, which contains the upgrade data, and a Readme file.

3.Copy the upgrade .HEX file into the Flash Wizard folder, which, in a default installation, is at C:\Program Files\MultiTech Systems\Flash Wizard\.

Step 5: Clear Your Stored Parameters

Before you flash your modem, you should record the parameters that are currently stored in it, so you can reprogram it after flashing. After you have recorded them, send the AT&W1Z command to the the modem to clear the stored parameters.

1.Run your favorite terminal program. If you are using Windows 95 or above, you can use Windows HyperTerminal.

2.In the program’s terminal window, type AT&V and press ENTER to list your modem’s current parameters.

3.Record your parameters by saving the screens and sending them to your printer.

4.Type AT&W1Z and press ENTER to clear your stored parameters and reset your modem to factory default.

5.Close the terminal program.

89

Image 86
Contents MT5634ZBA-V-V92 Record of Revisions Table of Contents AT Commands, S-Registers, and Result Codes Introduction Upgrade Overview Chapter Introduction Product Description MultiModemZBA-V-V92 User Guide IntroductionWe Supply You SupplyChapter Installation Mount the Feet Safety WarningsMultiModemZBA-V-V92 User Guide Installation Change the Internal Jumpers Opening the ModemChanging the Dial-Up/Leased-Line Jumpers MultiModemZBA-V-V92 User Guide2 InstallationLocation of the Jumpers Changing the Voice JumperConnect the Modem to You PC Connect the Two-Wire Leased LineConnect the Modem to Your System Connect the Modem to the Telephone LineConnect a Microphone and/or Speakers Optional Connect the Modem to the AC Power OutletConnect the Modem to a Phone Optional Connect the MicrophoneInstalling the Modem Driver Install the Modem DriverPower-On Test Surge Protectors and LightningUsing AT Commands to Configure Your Modem Configure the Modem for Your CountryUsing the Global Wizard to Configure Your Modem Click Initial Setup and Country SelectionInstall and Configure Your Software Chapter Operation Front Panel MultiModemZBA-V-V92 User Guide OperationConfiguring the Modem PhoneTools FeaturesSetup Leased Line OperationConnecting to the Internet OperationDial-Up Networking Sending a FaxChapter ATCommands,S-Registers,and ResultCodes Communication Standard Setting AT CommandsRepeat Last Command AnswerDS=n Dial Stored Telephone Number Echo Command Mode CharactersNumber ATDT1028806127853500$123456789 Echo Online Data CharactersResult Codes Enable/Disable Monitor Speaker ModeReturn Online to Data Mode Modulation HandshakeResult Code Format Modem ResetTone Dialing Result Code OptionsData Terminal Ready DTR Control Load Factory SettingsAsynchronous Communications Mode XON/XOFF Pacing ControlStore Current Configuration Test CommandsDisplay Current Settings Store Dialing Command\Bn Transmit Break \Kn Break Control\Qn Flow Control Selection \Nn Error Correction Mode Selection\Tn Inactivity Timer \V n Protocol Result CodeData Calling Tone Adaptive Answer Result Code EnableDC n AT Command Control View Numbers in BlacklistCommand Speed Response Direct Connect EnableCisco Configuration $Dn DTR DialingData Compression Reporting Command +DCS=x,y Select V.44 Data CompressionCommand +DS44=n V.44 Data Compression Enable Synchronous Buffered Mode SubparametersModulation Selection ModCommand +PCW= n Call Waiting Enable Mod value Valid maxrate values bpsPCM Upstream Ignore Modem on Hold EnableCommand +PMHR=n Modem on Hold Initiate Modem Hook FlashS109 Command +PMHT=n Modem on Hold TimerQuick Connect Control Command #CBDn Callback Delay Command +VCID=n Caller ID SelectionCommand +VDR=x, y Distinctive Ring Report Callback Attempts#CBIn Local Callback Inactivity Timer Command #CBF? Callback Failed Attempts DisplayCommand #CBFR Callback Failed Attempts Reset Command #CBNy=x Store Callback PasswordCommand +++ATCR Escape Sequence #Sx Enter Setup Password#S=x Store Setup Password Command %%%ATCR Remote Configuration Escape SequenceRegisters S38 Value RateS89 S42S48 S108Result Codes Terse Verbose DescriptionBlacklist Full Remote Configuration To Change the Setup Password Basic ProcedureSetup MultiModemZBA-V-V92 User Guide Remote ConfigurationTo Change the Remote Escape Character Callback Security CallbackSecurity MultiModemZBA-V-V92 User Guide Callback SecurityTo Turn Callback Security On and Off To Set the Parity of the Callback Security MessagesTo Assign Callback Passwords and Phone Numbers Password Calling ProceduresPassword-Only Callback Number-Entry CallbackExtension-Entry Callback Callback Security Commands Command #CBD n Callback DelayCommand #CBIn Local Callback Inactivity Timer #S x Enter Setup Password #S= x Store Setup PasswordCommand &Zy=+-x,???Store Dialing Command DT, or DP. Example AT&Z0=+-ATM0D5551212,???Callback Assignments Form MultiModemZBA-V-V92 User Guide6 Callback SecurityModem on Hold Operation MultiModemZBA-V-V92 User Guide Modem on Hold Operation What Is Modem on Hold?Modem on Hold Program Enable Modem on Hold Modem on Hold SettingsDisable Modem on Hold Enable Caller IDExit MTMoh Check Modem StatusAbout MTMoh Using Modem on Hold Answering a Voice CallResuming a Data Call Solving Problems None of the Indicators Light MultiModemZBA-V-V92 User Guide Solving ProblemsModem Does Not Respond to Commands Modem Cannot Connect When Dialing Modem Disconnects While Online Data Is Being Lost Modem Cannot Connect When AnsweringFile Transfer Is Slower Than It Should Be Fax and Data Software Can’t Run at the Same Time There Are Garbage Characters on the MonitorModem Doesn’t Work with Caller ID Appendixes FCC Part 68 Telecom MultiModemZBA-V-V92 User Guide Regulatory ComplianceFCC Part Fax Branding StatementInternational Modem Restrictions Canadian Limitations NoticeIndustry Canada EMC, Safety, and R&TTE Directive Compliance New Zealand Telecom Warning NoticeSouth African Notice Mode of Operation MultiModemZBA-V-V92 User Guide Technical SpecificationsError Correction Intelligent FeaturesDiagnostics Command BufferConnectors IndicatorsIdentify the Modem Firmware Upgrade OverviewIntroduction Identify the Current Firmware Version Download the Upgrade FileExtract the Upgrade Files Clear Your Stored ParametersUpgrade the Modem’s Firmware Restore Your ParametersStandard Linux Serial Port Definitions InstallationUsing the Terminal Program Minicom to Verify Operation Calling the ISP Using the Modem to Call the InternetSelect Dialup Configuration Tool Answering CallsConfigure for Callback Security in Direct Connect Mode Connecting to a Cisco Router Console PortConfigure the Modem for your Country MultiModemZBA-V-V92 User Guide Connecting to a Cisco RouterConsole Port Final Setup Console Port Connections Remote ConfigurationSignal RJ-45 pin DB-9 pin DB-25 pin Cable Pin-outs and Cabling Guide Console ModemMultiModemZBA-V-V92 User Guide Connecting to a Cisco Router Repair Procedures for U.S. and Canadian Customers Multi-Tech Systems, Inc. Warranty & Repairs PoliciesWarranty Repair Procedures for International Distributors International Customers outside U.S.A. and Canada Online Warranty Registration ServiceCanadian Customers Attn Repairs, Serial #Internet Sites Replacement PartsTechnical Support International DistributorsIndex Index 103 MultiModemZBA-V-V92 User Guide Index104

MT5634ZBA-V-V92 specifications

The Multi Tech Equipment MT5634ZBA-V-V92 is a versatile and reliable modem designed for various data communication applications. As a part of the MultiTech line of products, this modem is engineered to provide seamless connectivity in both dial-up and broadband environments. Its robust feature set ensures compatibility with a wide array of devices, making it a great choice for businesses and individuals alike.

One of the main features of the MT5634ZBA-V-V92 is its ability to operate at V.92 speeds, allowing for data transmission rates of up to 56 Kbps. This makes it suitable for sending and receiving large amounts of data quickly, a significant advantage for businesses that require efficient communication. The modem is also backward compatible with previous V.90 technologies, ensuring that it can connect with older systems without any issues.

Another notable aspect of the MT5634ZBA-V-V92 is its built-in error correction and data compression capabilities. These technologies significantly enhance data integrity and transmission speed, resulting in fewer dropped connections and faster downloads. The modem uses state-of-the-art compression algorithms to optimize data flow, making it ideal for applications that require reliable and swift data exchange.

In terms of connectivity, the MT5634ZBA-V-V92 supports various interfaces, including RS-232, which allows for easy integration with a wide range of computer systems and other devices. Its flexibility in interfacing options makes it suitable for diverse environments, from industrial applications to home office setups.

The modem's design is also focused on user-friendliness. It comes equipped with LED indicators that provide real-time status updates on power, data transmission, and network connection, allowing users to monitor their connections effortlessly. Additionally, the device includes a simple installation process, which minimizes downtime and helps users get up and running quickly.

The MT5634ZBA-V-V92 is built to last, with a sturdy construction that ensures durability in demanding conditions. Its compact design allows for easy mounting and placement, making it an excellent choice for both stationary and mobile applications.

Overall, the Multi Tech Equipment MT5634ZBA-V-V92 is a powerful modem that merges speed, reliability, and flexibility. With its advanced features and technologies, it stands out as a dependable solution for anyone in need of high-performance data communication. Whether for business or personal use, this modem meets the connectivity needs of today's digital landscape with ease.