Multi Tech Equipment MT5634ZBA-V-V92 manual AT Commands, S-Registers, and Result Codes

Page 4

MultiModemZBA-V-V92 User Guide

Contents

Chapter 4- AT Commands, S-Registers, and Result Codes

.................................... 20

AT Commands

21

S-Registers

40

Result Codes

43

Chapter 5 - Remote Configuration

47

Basic Procedure

47

Setup

47

Chapter 6 - Callback Security

57

Setup

57

Calling Procedures

60

Callback Security Commands

62

Callback Assignments Form

66

Chapter 7 - Modem on Hold Operation

68

What Is Modem on Hold?

68

The Modem on Hold Program

68

Using Modem on Hold

71

Chapter 8 - Solving Problems

74

None of the Indicators Light

74

The Modem Does Not Respond to Commands

75

The Modem Cannot Connect When Dialing

76

The Modem Disconnects While Online

77

The Modem Cannot Connect When Answering

78

File Transfer Is Slower Than It Should Be

78

Data Is Being Lost

78

There Are Garbage Characters on the Monitor

79

The Modem Doesn’t Work with Caller ID

79

Fax and Data Software Can’t Run at the Same Time

79

iv

Image 4
Contents MT5634ZBA-V-V92 Record of Revisions Table of Contents AT Commands, S-Registers, and Result Codes Introduction Upgrade Overview Chapter Introduction Product Description MultiModemZBA-V-V92 User Guide IntroductionWe Supply You SupplyChapter Installation MultiModemZBA-V-V92 User Guide Installation Safety WarningsMount the Feet Change the Internal Jumpers Opening the ModemMultiModemZBA-V-V92 User Guide2 Installation Location of the JumpersChanging the Dial-Up/Leased-Line Jumpers Changing the Voice JumperConnect the Two-Wire Leased Line Connect the Modem to Your SystemConnect the Modem to You PC Connect the Modem to the Telephone LineConnect the Modem to the AC Power Outlet Connect the Modem to a Phone OptionalConnect a Microphone and/or Speakers Optional Connect the MicrophoneInstall the Modem Driver Power-On TestInstalling the Modem Driver Surge Protectors and LightningConfigure the Modem for Your Country Using the Global Wizard to Configure Your ModemUsing AT Commands to Configure Your Modem Click Initial Setup and Country SelectionInstall and Configure Your Software Chapter Operation Front Panel MultiModemZBA-V-V92 User Guide OperationConfiguring the Modem PhoneTools FeaturesSetup Leased Line OperationConnecting to the Internet OperationDial-Up Networking Sending a FaxChapter ATCommands,S-Registers,and ResultCodes AT Commands Repeat Last CommandCommunication Standard Setting AnswerEcho Command Mode Characters Number ATDT1028806127853500$123456789DS=n Dial Stored Telephone Number Echo Online Data CharactersMonitor Speaker Mode Return Online to Data ModeResult Codes Enable/Disable Modulation HandshakeModem Reset Tone DialingResult Code Format Result Code OptionsLoad Factory Settings Asynchronous Communications ModeData Terminal Ready DTR Control XON/XOFF Pacing ControlTest Commands Display Current SettingsStore Current Configuration Store Dialing Command\Bn Transmit Break \Kn Break Control\Nn Error Correction Mode Selection \Tn Inactivity Timer\Qn Flow Control Selection \V n Protocol Result CodeAdaptive Answer Result Code Enable DC n AT Command ControlData Calling Tone View Numbers in BlacklistDirect Connect Enable Cisco ConfigurationCommand Speed Response $Dn DTR DialingCommand +DS44=n V.44 Data Compression Command +DCS=x,y Select V.44 Data CompressionData Compression Reporting Enable Synchronous Buffered Mode SubparametersModulation Selection ModCommand +PCW= n Call Waiting Enable Mod value Valid maxrate values bpsModem on Hold Enable Command +PMHR=n Modem on Hold InitiatePCM Upstream Ignore Modem Hook FlashQuick Connect Control Command +PMHT=n Modem on Hold TimerS109 Command +VCID=n Caller ID Selection Command +VDR=x, y Distinctive Ring ReportCommand #CBDn Callback Delay Callback AttemptsCommand #CBF? Callback Failed Attempts Display Command #CBFR Callback Failed Attempts Reset#CBIn Local Callback Inactivity Timer Command #CBNy=x Store Callback Password#Sx Enter Setup Password #S=x Store Setup PasswordCommand +++ATCR Escape Sequence Command %%%ATCR Remote Configuration Escape SequenceRegisters S38 Value RateS42 S48S89 S108Result Codes Terse Verbose DescriptionBlacklist Full Remote Configuration Basic Procedure SetupTo Change the Setup Password MultiModemZBA-V-V92 User Guide Remote ConfigurationTo Change the Remote Escape Character Callback Security CallbackSecurity MultiModemZBA-V-V92 User Guide Callback SecurityTo Turn Callback Security On and Off To Set the Parity of the Callback Security MessagesTo Assign Callback Passwords and Phone Numbers Calling Procedures Password-Only CallbackPassword Number-Entry CallbackExtension-Entry Callback Callback Security Commands Command #CBD n Callback DelayCommand #CBIn Local Callback Inactivity Timer #S x Enter Setup Password #S= x Store Setup PasswordCommand &Zy=+-x,???Store Dialing Command DT, or DP. Example AT&Z0=+-ATM0D5551212,???Callback Assignments Form MultiModemZBA-V-V92 User Guide6 Callback SecurityModem on Hold Operation Modem on Hold Program What Is Modem on Hold?MultiModemZBA-V-V92 User Guide Modem on Hold Operation Modem on Hold Settings Disable Modem on HoldEnable Modem on Hold Enable Caller IDAbout MTMoh Check Modem StatusExit MTMoh Using Modem on Hold Answering a Voice CallResuming a Data Call Solving Problems None of the Indicators Light MultiModemZBA-V-V92 User Guide Solving ProblemsModem Does Not Respond to Commands Modem Cannot Connect When Dialing Modem Disconnects While Online File Transfer Is Slower Than It Should Be Modem Cannot Connect When AnsweringData Is Being Lost Modem Doesn’t Work with Caller ID There Are Garbage Characters on the MonitorFax and Data Software Can’t Run at the Same Time Appendixes FCC Part 68 Telecom MultiModemZBA-V-V92 User Guide Regulatory ComplianceFCC Part Fax Branding StatementIndustry Canada Canadian Limitations NoticeInternational Modem Restrictions EMC, Safety, and R&TTE Directive Compliance New Zealand Telecom Warning NoticeSouth African Notice MultiModemZBA-V-V92 User Guide Technical Specifications Error CorrectionMode of Operation Intelligent FeaturesCommand Buffer ConnectorsDiagnostics IndicatorsIntroduction Upgrade OverviewIdentify the Modem Firmware Download the Upgrade File Extract the Upgrade FilesIdentify the Current Firmware Version Clear Your Stored ParametersUpgrade the Modem’s Firmware Restore Your ParametersUsing the Terminal Program Minicom to Verify Operation InstallationStandard Linux Serial Port Definitions Using the Modem to Call the Internet Select Dialup Configuration ToolCalling the ISP Answering CallsConnecting to a Cisco Router Console Port Configure the Modem for your CountryConfigure for Callback Security in Direct Connect Mode MultiModemZBA-V-V92 User Guide Connecting to a Cisco RouterConsole Port Final Setup Remote Configuration Signal RJ-45 pin DB-9 pin DB-25 pinConsole Port Connections Cable Pin-outs and Cabling Guide Console ModemMultiModemZBA-V-V92 User Guide Connecting to a Cisco Router Warranty Multi-Tech Systems, Inc. Warranty & Repairs PoliciesRepair Procedures for U.S. and Canadian Customers Repair Procedures for International Distributors Online Warranty Registration Service Canadian CustomersInternational Customers outside U.S.A. and Canada Attn Repairs, Serial #Replacement Parts Technical SupportInternet Sites International DistributorsIndex Index 103 MultiModemZBA-V-V92 User Guide Index104

MT5634ZBA-V-V92 specifications

The Multi Tech Equipment MT5634ZBA-V-V92 is a versatile and reliable modem designed for various data communication applications. As a part of the MultiTech line of products, this modem is engineered to provide seamless connectivity in both dial-up and broadband environments. Its robust feature set ensures compatibility with a wide array of devices, making it a great choice for businesses and individuals alike.

One of the main features of the MT5634ZBA-V-V92 is its ability to operate at V.92 speeds, allowing for data transmission rates of up to 56 Kbps. This makes it suitable for sending and receiving large amounts of data quickly, a significant advantage for businesses that require efficient communication. The modem is also backward compatible with previous V.90 technologies, ensuring that it can connect with older systems without any issues.

Another notable aspect of the MT5634ZBA-V-V92 is its built-in error correction and data compression capabilities. These technologies significantly enhance data integrity and transmission speed, resulting in fewer dropped connections and faster downloads. The modem uses state-of-the-art compression algorithms to optimize data flow, making it ideal for applications that require reliable and swift data exchange.

In terms of connectivity, the MT5634ZBA-V-V92 supports various interfaces, including RS-232, which allows for easy integration with a wide range of computer systems and other devices. Its flexibility in interfacing options makes it suitable for diverse environments, from industrial applications to home office setups.

The modem's design is also focused on user-friendliness. It comes equipped with LED indicators that provide real-time status updates on power, data transmission, and network connection, allowing users to monitor their connections effortlessly. Additionally, the device includes a simple installation process, which minimizes downtime and helps users get up and running quickly.

The MT5634ZBA-V-V92 is built to last, with a sturdy construction that ensures durability in demanding conditions. Its compact design allows for easy mounting and placement, making it an excellent choice for both stationary and mobile applications.

Overall, the Multi Tech Equipment MT5634ZBA-V-V92 is a powerful modem that merges speed, reliability, and flexibility. With its advanced features and technologies, it stands out as a dependable solution for anyone in need of high-performance data communication. Whether for business or personal use, this modem meets the connectivity needs of today's digital landscape with ease.