Sierra Wireless 300 manual Modem Features, Radio Specifications

Page 24

DART 300 Migration Guide

Difference Summary

3.4.Specifications

3.4.1.Modem Features

 

DART 200

DART 300

 

 

 

CDPD Version supported

1.0 & 1.1

1.1 only

Maximum packet size (bytes)

1924 (or less as determined

User adjustable (+WS74)

 

by TCP handshake)

from 1 – 1000.

V.42bis compression

Optional

No

 

 

 

Sleep mode (power reduction)

No

Yes (three levels)

 

 

 

Software controlled re-boot

Yes

Yes

Service Provider Mode

Yes

No

 

 

 

Dial Directory

Yes

Yes

 

 

 

Network status over RS232

Yes

No

control signals

 

 

View Profile

Yes (&V and &V+)

No

PING Generation

Yes

No

 

 

 

Onboard Diagnostics

Yes

No

 

 

 

Connection Failure Probable

Yes

No

Cause

 

 

Personal Identification

Yes

No

Number (PIN)

 

 

Service Provider Key (SPK)

Yes

No

Friends Only

Yes

Yes

 

 

 

3.4.2.Radio Specifications

 

DART 200

DART 300

 

 

 

Transmitter Power

Maximum 3 W

Maximum 600 mW into

 

 

50

 

 

Supports AirBooster 350

 

 

RF Amplifier for 3 W

 

 

operation.

Receiver Sensitivity

Not specified

-108 dBm 5% BLER

2110291 Rev 1.0

Page 18

Image 24
Contents Sierra Wireless Dart 300 Cdpd Modem Safety and Hazards Important NoticePatents CopyrightRegulatory Information RSA Licensee Contact InformationContents Comparative AT Command Reference Dart 300 Modem Migration GuideIntroduction ReferencesDocument Structure Currency Conventions Used in this ReferenceDart 300 / SB300 Rev 1.0 November 8Sample UDP Setups +WS62=0 +WS63=0\Q0 +WS70=20Q0 default Disable Quiet mode F1 default Sample TCP Setups \J0 +WPSPNI=enter\O0 +WS45=1 S86=3 \J0 default +WS70=20 Serial Interface Specifications InterfacesDart Control Lines RTS/CTSPacket Service Interfaces Modem Control InterfaceOperation Monitoring Network ConnectionChannel Acquisition Restrictions TCP Characteristics TCP Keep-AliveUDP Characteristics UDP Receive LockingPacket Assembly / Disassembly PAD Features Additional Control ConsiderationsEscape Sequence Packet Assembly Local Echo Packet ForwardingManual Transmission Automatic TransmissionSpecifications Modem FeaturesRadio Specifications Electrical Specification AT Command Set Basic AT Commands Dart +++AT+++ 0xC0Basic AT Commands Dart Options +WS45PAD Local On-Line Echo +WS62=1Basic AT Commands Dart AT & Commands DartSn=x Sn?S2=128 +WS60=0 S2=43 +WS60=1S126 AT \ Commands Dart Dart 300 Equivalent \F0 = +WS63=1\F1-3 = +WS63=3 \J0 = +WPSPNI=enterAT * Commands Dart Dart 300 Equivalent +WPREG and +WPDEREG\R0 \R1= S30=0 K1-2 =S30=t Lp= +WS212=pAT Commands Dart Dart 300 Equivalent Aip/n= +WS197=n+WPNEI=ip Hspni/nWith +WPCHAN Ln = +WPCHAN=n = +WPCHAN=0 Dart 300 Specific Commands AT + CommandsIndication RSSI, channel state, registration Status, and channel numberStatus Registers RegistersRegisters Dart S-Registers Dart B0,1 +WS56?B2,3 B4,5 +WS173?100 101102 With +WPRSSIWS-Registers in the Dart Result Codes 10 Dart 300 Result Codes Verbose Dart 300 Meaning