4.Comparative AT Command Reference
4.1. Introduction
This chapter compares the AT commands available on the DART 300 with those of the original DART 200. This is not intended as a complete reference to the AT Command behaviour, but instead identifies the differences in behaviour of commands and offers suggested alternatives where the new DART 300 does not support the same functionality as the original DART 200.
There is also a cross reference for commands that exist on the DART 300 but not on the
DART 200. These allow users familiar with the DART 200 to better understand command syntax from the DART 300 by finding the roughly equivalent DART 200 commands.
The phrase “Not supported” indicates that the command syntax is not directly supported. The functionality may be provided by a different mechanism, which will be described in the table. If no explanatory text is provided, then there is not an equivalent function available.
4.2. AT Command Set
The following tables list the commands grouped by their prefix. AT is assumed at the beginning of all commands except where specified. A space following the “AT” is optional.
Table 4-1 Basic AT Commands
Command | DART 200 | DART 300 |
|
|
|
+++ | Time Dependent Escape Sequence (TDES) | Time Dependent Escape Sequence (TDES) |
| Uses a sequence of EGEGE where the guard | Uses a sequence of GEEEG. That is: a |
| time between successive characters must meet | preceding and trailing guard time with the time |
| or exceed the time set in S12. | between successive escape characters less than |
|
| the guard time. |
AT+++ | Not Supported. | Time Independent Escape Sequence (TIES). |
|
| Offered only in TCP or UDP mode. |
<0xC0> | Not Supported. | Escape sequence (SLIP service) |
+++ |
| Not preceded by AT. There are no guard |
<0xC0> |
| |
| times associated with this escape sequence. | |
|
| |
A/ | Repeat Last Command | Repeat Last Command |
| Not preceded by AT. | Same behaviour. |
| command string entered (buffered). |
|
A | Answer – Manual | Answer – Manual |
| Behaviour and result codes discussed in the | Similar behaviour in practice but details are |
| DART 200 reference. | different from the DART 200. Result codes |
|
| are also interpreted differently. Consult the |
|
| respective product references for details. |
2110291 Rev 1.0 | Page 20 |