Motion MMI-8S installation manual Clear, Load F6, Exit F5, W,O, Smc

Page 21

Reserved and Special Software Commands.

 

CLEAR

Writes 0's and CR's to memory.

 

LOAD [F6]

Loads memory. Not same function as Basic F3 key.

 

EXIT [F5]

Required to close comm port, close file, and clear error traps.

 

comma [,]

Do not use comma to separate elements of 545 commands (T,L, and ?

M

xx). Comma is a Basic symbol; use space instead.

 

[a,b,c]

HP-LED command string is not used.

 

C

Continuous Step Mode is normally not used with the CY545 unless

 

motion can be terminated with an external Abort signal. Refer also

to the

CY550 which is an advanced version which has a larger

selection of on-the-fly

software commands.

 

Special Aspects of Some Commands.

WThe Wait command causes the 545 to wait at the instruction, therefore incoming stop commands will not be processed. Use a T command in a jump to itself.

L, Z

These loop instructions assume that the first pass of a routine

 

before reaching the loop command was the 1st loop pass. In

 

general, the loop count must be one less than required. Also

 

see J & T below.

T,H,W,O

These commands are followed by a numeric value in Hexdecimal

 

which is desinated by the H following the value. The decimal and

 

the hex values for 0 to 7 are the same and the H can be omitted.

H

Homing is a single step operation. The Busy signal is not

 

continuously set during homing but cycles every step. It is best

 

therefore that homing is executed from memory.

J, T

Any Jump or Test operation, which includes L & Z commands,

 

must not cross the memory page boundry which is ever 256

 

bytes; 256, 512, 768, 1024, etc. Use the Y for global jumps.

Installation and Test Procedure

1.Connect AC power cord.

2.Connect motors, verify that driver current is correct for motors. See Appendix C for current adjustment and Appendix D for motor wiring.

3.Connect CI cable. Limit Loop must be closed for motor to run.

4.Connect the serial cable and turn-on computer system.

5.Connect the AC power and turn-on power switch or supplies. Verify

that: AC neon; power is present. DC lamp; motor power (VMM) is OK. All

SMC

LEDs are off except for BUSY.

 

Image 21
Contents MMI-8S MULTI-AXES Motion System Introduction Page Page Page SR4 CY 233 Command SET Summary ContentsWrite ReadIntroduction TOP Cover Removal Procedure Service AccessHardware Description OperationWrite Mode Read ModeStatus ID and Status Codes Echo ModeTable of ID and Status Codes Programming LED DisplaysPage Page CY 545 Command SET Summary SMC Step Motion Controller Assembly Also Refer toPage Page Page Page Page Load F6 ClearExit F5 W,OPage ADW0D YESPage Page Program Listings See Mmidemo program PIN XT Type CPU DB-25 IBM StyleAT Type CPU DB-9P IBM Style MAC DINFuse Failure Indicates Driver Failure MMIPage MS MiniStep translator /driver card Operation and Installation Manual For MS SeriesPage Page Power Supply & Motor Connections GND Current Control Dial Appendix Section Page Appendix B Description of Homing and Abort Loop page 1/2 Appendix B Description of Homing and Abort Loop page 2/2 Appendix C Motor Current Adjust Appendix D Motor Wiring Schemes Page Page Appendix E Appendix F 2/2 Appendix Specifications MMI Parameter MIN MAX Unit