Sony RX100 manual BBV Rx100 Interface Receiver

Page 14

BBV Rx100 Interface Receiver

Addendum to manual for the following domes:

360 Vision VisionDome

Gardiner Security Juno

Rx100 software RX1_31V2

Application Notes

The RX 100 provide the following functionality when controlling the above mentioned domes

Variable speed Pan/Tilt.

Zoom/Focus, Focus/Iris Override returning to auto after Zoom In/Out.

16 Full scene presets.

2 preset patrols.

Slow preset tour. Started by pressing AUTOPAN (As patrol 1 but slow speed movement and 10 second dwell)

5 minute datum/park driving to preset 1 or slow preset tour. Disabled by removing link J6/1-2 Program up to 16 privacy zones

Additional commands:

AUTOPAN: Pressing the AUTOPAN key will run the domes preset tour at slow speed between the patrol 1 preset positions.

Advanced Features

Tx400

Tx1000

Tx1500

DM DS/DS2/BX2 Mux

 

180 degree pan flip

‘#’ 1

'#' WASH

1 ’#’

*889 002 or *889 10 10 2

Privacy SET (enable)

‘#’ 2

'#' WIPE

2 ’#’

*889 003 or *889 10 10 3

Privacy CLEAR (disable)

‘#’ 3

'#' AUTOPAN

3 ’#’

*889 004 or *889 10 10 4

Reset dome parameters

‘#’ 4

'#' LIGHTS

4 ’#’

*889 005 or *889 10 10 5

The dome and Rx100 are linked using RS485 for control and video for the camera signal.

Rx100

Description

Dome connection

J3-C1

TX-/B

D-

J3-C2

TX+/A

D+

Notes:

The dome address must be set at 1 for all the cameras that are controlled using a Rx100. Check with the dome manual if you have any doubts. The alarm output relay opens for approx 5 seconds upon power up and following any active alarm input.

If the slow preset tour is running, start patrol 1 & 2 is inhibited. The dome will be driven to a preset following an alarm activation. 60 seconds after alarm, the tour will restart. A manual goto preset and lens control will stop the tour leaving the AUTOPAN led on until the next manual pan command.

A datum/park mode is offered that drives the dome to preset 1 following 5 minutes of inactivity. This can be disabled by removing the link fitted across J6/pin 4 & 5. and refitting to J6/pin 3 & 4.

Privacy zone programming.

The keystrokes shown assume use of a TX1500. Use the keystroke shown above if using another controller.

Programming a zone

The Rx100 can be used to program 16 privacy zones. The same procedure that is used to program a preset position is used to program or clear a privacy zone. To instruct the Rx100 to program a privacy zone press 2# followed by program preset 1 – 16. The screen will then go blank showing that the privacy zone has been set.

Clearing a zone

To clear/delete a privacy zone press 3# followed by program preset 1 – 16. The relevant privacy zone will then be disabled and the dome will move to show the zone that has been disabled so that the zone can easily be re-enabled if disabled in error.

J6 Links

J6/1-2 fitted to enable the 5 minute datum mode. After 5 minutes of inactivity the dome will be driven to either preset 1 or a slow preset tour is started depending upon link J6/4-5. J6/4-5 fitted = goto preset 1,J6/3-4 = start slow preset tour.

Intended for up-the-coax control.

When using 20mA TP telemetry control maybe slightly sluggish.

Rx100 installation manual V1.17 29 Aug 08.doc

Page 14

Image 14 Contents
Installation Guide Table of Contents Important Safety Precautions UnpackingRx100 installation manual V1.17 29 Aug 08.doc General RX100/WBXTransmitter Compatability Chart Tx300 Tx400 Tx400DC Tx1000 Tx1000DC Tx1500Cable Connection Method Function Connector Type Operating VoltageDiagnostic Aids Video Launch Amplifier and Cable Length Compensation Rx100 Rx200 Rx300 Rx400P Rx400DC Rx45X AC Rx55X DC Simple Single Camera System Appendix a Dome addendums & connection details BBV Rx100/24 Supply Additional information iss pcb BBV Rx100 Interface Receiver # Autopan DAY Night ModeRX+ ‘#’ LightsBBV Rx 100 Interface Receiver TX+Rx100 software RX1D4V7 DM/DS/DSL/DS2Disable around Cursor Enable ALL SceneDisable ALL Scene AUTO/MANUAL Focus Toggle# Wash TX-/B TX+/ATxdi # Autopan# Lights TXDI+TX/RX+ TX/RXRED GreenBBV Rx 100 Interface Receiver ENTRY/EXIT Dome Menu ‘#’ # Wash ’#’ RX+ Lights Wiper WasherDM-DSL/DS/DS2 DS/DSL/DS2/BX2 Using the advanced features when using a BBV Tx1000DCReset Dome ‘#’ AutopanUsing the advanced features when using a BBV Tx400DC Control from DM Digital Sprite 2 systemsMenu Access when using DM DS/DSL/DS2 Menu Access when using a BBV Tx1000DCMenu Access when using a BBV Tx400DC Turn Menu Off *889 10 10DM DS/DS2/BX2 ‘#’ Lights AUTO, INDOOR, Outdoor‘#’ Autopan J3/GNDTX/RX TX/RX+Application Notes Privacy SET Toggle Mono/Colour ‘#’ # Wipe ’#’ TX/RX Comm AUX1AUX2 TX/RX+ Comm IN+’#’ 889 004 or *889 10 10 Stop Recording ‘#’ Protocol P/D RS485 B Appendix B Trouble shooting guide Blank for your notes VCL/HONEYWELL RS485 PHILIPS/BOSCH RS485 Optional BI-PHASE InputPelco P/D RS485 Dennard RS485