BBV Rx100 Interface Receiver
Addendum to manual for the following domes:
360 Vision VisionDome
Gardiner Security Juno
Rx100 software RX1_31V2
Application Notes
The RX 100 provide the following functionality when controlling the above mentioned domes
Variable speed Pan/Tilt.
Zoom/Focus, Focus/Iris Override returning to auto after Zoom In/Out.
16 Full scene presets.
2 preset patrols.
Slow preset tour. Started by pressing AUTOPAN (As patrol 1 but slow speed movement and 10 second dwell)
5 minute datum/park driving to preset 1 or slow preset tour. Disabled by removing link
Additional commands:
AUTOPAN: Pressing the AUTOPAN key will run the domes preset tour at slow speed between the patrol 1 preset positions.
Advanced Features | Tx400 | Tx1000 | Tx1500 | DM DS/DS2/BX2 Mux |
|
180 degree pan flip | ‘#’ 1 | '#' WASH | 1 ’#’ | *889 002 or *889 10 10 2 | |
Privacy SET (enable) | ‘#’ 2 | '#' WIPE | 2 ’#’ | *889 003 or *889 10 10 3 | |
Privacy CLEAR (disable) | ‘#’ 3 | '#' AUTOPAN | 3 ’#’ | *889 004 or *889 10 10 4 | |
Reset dome parameters | ‘#’ 4 | '#' LIGHTS | 4 ’#’ | *889 005 or *889 10 10 5 |
The dome and Rx100 are linked using RS485 for control and video for the camera signal.
Rx100 | Description | Dome connection |
D- | ||
TX+/A | D+ |
Notes:
The dome address must be set at 1 for all the cameras that are controlled using a Rx100. Check with the dome manual if you have any doubts. The alarm output relay opens for approx 5 seconds upon power up and following any active alarm input.
If the slow preset tour is running, start patrol 1 & 2 is inhibited. The dome will be driven to a preset following an alarm activation. 60 seconds after alarm, the tour will restart. A manual goto preset and lens control will stop the tour leaving the AUTOPAN led on until the next manual pan command.
A datum/park mode is offered that drives the dome to preset 1 following 5 minutes of inactivity. This can be disabled by removing the link fitted across J6/pin 4 & 5. and refitting to J6/pin 3 & 4.
Privacy zone programming.
The keystrokes shown assume use of a TX1500. Use the keystroke shown above if using another controller.
Programming a zone
The Rx100 can be used to program 16 privacy zones. The same procedure that is used to program a preset position is used to program or clear a privacy zone. To instruct the Rx100 to program a privacy zone press 2# followed by program preset 1 – 16. The screen will then go blank showing that the privacy zone has been set.
Clearing a zone
To clear/delete a privacy zone press 3# followed by program preset 1 – 16. The relevant privacy zone will then be disabled and the dome will move to show the zone that has been disabled so that the zone can easily be
J6 Links
Intended for
When using 20mA TP telemetry control maybe slightly sluggish.
Rx100 installation manual V1.17 29 Aug 08.doc | Page 14 |