Sony RX100 manual AUTO, INDOOR, Outdoor, ‘#’ Autopan, ‘#’ Lights, J3/GND

Page 30

BBV Rx 100 Interface Receiver

Addendum to manual for the following camera:

Sony EVI-D31 Webcam

Rx100 software RXS4V3

Coaxial telemetry ONLY. Not twisted pair.

Application Notes

Variable speed Pan/Tilt.

Zoom/Focus, Autofocus with manual override (returns to auto following zoom command) 6 full scene presets

2 preset patrols

4 alarm inputs driving to preset 1 – 4

Advanced Features

Tx400

Tx1000

Tx1500 DM Sprite/DS2/BX2

Toggle Backlight compensation

'#' ‘1’

‘#’ WASH

1 ‘#’

*889 002 or 10 10 2

Cycle White Balance

‘#’ ‘2’

‘#’ WIPE

2 ‘#’

*889 003 or 10 10 3

AUTO, INDOOR, OUTDOOR

 

 

 

 

Toggle AutoExposure/Bright mode

‘#’ ‘3’

‘#’ AUTOPAN

3 ‘#’

*889 004 or 10 10 4

Iris keys used in Bright mode

 

 

 

 

Reset dome to default

‘#’ ‘4’

‘#’ LIGHTS

4 ‘#’

*889 005 or 10 10 5

RS232 control of dome 9600 Baud, No parity, 8 data bits, 1 stop bit. The camera uses a sub-miniature 8 pin DIN socket. A Sony supplied VISCA to DB9 RS232 cable may help with installation.

Connection details:

Camera Pin

Description

Rx100

 

5

Receive Data

J3/C1

4 or 6

Ground

J3/GND

Notes:

Link J6/1-2 selects a 5 minute datum mode. If fitted and no activity for 5 minutes, the camera will drive to either preset 1 or start PATROL 1 depending on link J6/3,4,5, Fitted to J6/4&5 = Goto Preset 1 or fitted to J6/3&4 = start PATROL 1.

The alarm output relay opens for approx 5 seconds upon power up. This can be used to signal power loss, etc.

Check with the multiplexer manual for exact procedure for entering * commands.

IMPORTANT:

Ensure that CAMERA NO switch on the camera rear panel is set to 1.

As communications is RS232 please limit cable from Rx100 to camera to less than 5M.

Rx100 installation manual V1.17 29 Aug 08.doc

Page 30

Image 30 Contents
Installation Guide Table of Contents Important Safety Precautions UnpackingRx100 installation manual V1.17 29 Aug 08.doc General RX100/WBXTransmitter Compatability Chart Tx300 Tx400 Tx400DC Tx1000 Tx1000DC Tx1500Cable Connection Method Function Connector Type Operating VoltageDiagnostic Aids Video Launch Amplifier and Cable Length CompensationRx100 Rx200 Rx300 Rx400P Rx400DC Rx45X AC Rx55X DC Simple Single Camera System Appendix a Dome addendums & connection details BBV Rx100/24 Supply Additional information iss pcb BBV Rx100 Interface Receiver # Autopan DAY Night ModeRX+ ‘#’ LightsBBV Rx 100 Interface Receiver TX+Rx100 software RX1D4V7 DM/DS/DSL/DS2Disable around Cursor Enable ALL SceneDisable ALL Scene AUTO/MANUAL Focus Toggle# Wash TX-/B TX+/ATxdi # Autopan# Lights TXDI+TX/RX+ TX/RXRED GreenBBV Rx 100 Interface Receiver ENTRY/EXIT Dome Menu ‘#’ # Wash ’#’ Lights Wiper Washer DM-DSL/DS/DS2RX+ DS/DSL/DS2/BX2 Using the advanced features when using a BBV Tx1000DC Reset Dome ‘#’ AutopanUsing the advanced features when using a BBV Tx400DC Control from DM Digital Sprite 2 systemsMenu Access when using DM DS/DSL/DS2 Menu Access when using a BBV Tx1000DCMenu Access when using a BBV Tx400DC Turn Menu Off *889 10 10DM DS/DS2/BX2 ‘#’ Lights AUTO, INDOOR, Outdoor‘#’ Autopan J3/GNDTX/RX TX/RX+Application Notes Privacy SET Toggle Mono/Colour ‘#’ # Wipe ’#’ TX/RX Comm AUX1AUX2 TX/RX+ Comm IN+’#’ 889 004 or *889 10 10 Stop Recording ‘#’ Protocol P/D RS485 B Appendix B Trouble shooting guide Blank for your notes VCL/HONEYWELL RS485 PHILIPS/BOSCH RS485 Optional BI-PHASE InputPelco P/D RS485 Dennard RS485