Sony RX100 manual ’#’ 889 004 or *889 10 10 Stop Recording ‘#’

Page 35

BBV Rx100 Interface Receiver

Addendum to manual for the following domes:

Videcon Dome

Rx100 software RX1_V4V2

Application Notes

The RX 100 provide the following functionality when controlling the above mentioned dome

Variable speed Pan/Tilt.

16 Full scene presets.

2 RX100 preset patrols.

Pattern Tour 1 learn and playback using AUTOPAN Privacy zone support

IR Filter CUT using LIGHTS is link J6/1-2 fitted. Lights ON = FILTER OFF, Lights OFF = FILTER ON

Advanced Features

Tx400

Tx1000

Tx1500

DM DS/DS2/BX2 Mux

 

Display MENU

‘#’ 1

'#' WASH

1 ’#’

*889 002 or *889 10 10 2

Display Privacy Menu

‘#’ 2

'#' WIPE

2 ’#’

*889 003 or *889 10 10 3

Record Pattern Tour 1

‘#’ 3

'#' AUTOPAN

3 ’#’

*889 004 or *889 10 10 4

Stop Recording

‘#’ 4

‘#’ LIGHTS

4 ‘#’

*889 005 or *889 10 10 5

Pattern Tour 1 playback = press AUTOPAN

The dome and Rx100 are linked using RS485 for control and video for the camera signal.

Rx100

Description

Dome connection

J3-C1

TX-/B

D-

J3-C2

TX+/A

D+

Notes:

The dome switches must be as follows to select Pelco P, 9600 baud and address 1.

SW1, 1 ON, 2-7 OFF. SW2, 1 & 2 ON, Protocol switch 1-4 all OFF

The alarm output relay opens for approx 5 seconds upon power up and following any active alarm input.

When navigating the dome’s menu or privacy setup use the joystick and IRIS OPEN and CLOSE. The dome manual has detailed information on the menu structure and privacy setting.

J6 Links

J6/1-2 fitted to allow LIGHTS to switch the IR CUT filter ON/OFF when used with a day/night dome.

Rx100 installation manual V1.17 29 Aug 08.doc

Page 35

Image 35 Contents
Installation Guide Table of Contents Unpacking Important Safety PrecautionsRx100 installation manual V1.17 29 Aug 08.doc RX100/WBX GeneralTx300 Tx400 Tx400DC Tx1000 Tx1000DC Tx1500 Transmitter Compatability ChartCable Connection Method Operating Voltage Function Connector TypeVideo Launch Amplifier and Cable Length Compensation Diagnostic AidsRx100 Rx200 Rx300 Rx400P Rx400DC Rx45X AC Rx55X DC Simple Single Camera System Appendix a Dome addendums & connection details BBV Rx100/24 Supply Additional information iss pcb BBV Rx100 Interface Receiver ‘#’ Lights DAY Night ModeRX+ # AutopanTX+ BBV Rx 100 Interface ReceiverDM/DS/DSL/DS2 Rx100 software RX1D4V7AUTO/MANUAL Focus Toggle Enable ALL SceneDisable ALL Scene Disable around Cursor# Wash TX+/A TX-/BTXDI+ # Autopan# Lights TxdiGreen TX/RXRED TX/RX+BBV Rx 100 Interface Receiver ENTRY/EXIT Dome Menu ‘#’ # Wash ’#’ RX+ Lights Wiper WasherDM-DSL/DS/DS2 ‘#’ Autopan Using the advanced features when using a BBV Tx1000DCReset Dome DS/DSL/DS2/BX2Control from DM Digital Sprite 2 systems Using the advanced features when using a BBV Tx400DCTurn Menu Off *889 10 10 Menu Access when using a BBV Tx1000DCMenu Access when using a BBV Tx400DC Menu Access when using DM DS/DSL/DS2DM DS/DS2/BX2 J3/GND AUTO, INDOOR, Outdoor‘#’ Autopan ‘#’ Lights TX/RX+ TX/RXApplication Notes Privacy SET Toggle Mono/Colour ‘#’ # Wipe ’#’ TX/RX+ Comm IN+ AUX1AUX2 TX/RX Comm’#’ 889 004 or *889 10 10 Stop Recording ‘#’ Protocol P/D RS485 B Appendix B Trouble shooting guide Blank for your notes Dennard RS485 PHILIPS/BOSCH RS485 Optional BI-PHASE InputPelco P/D RS485 VCL/HONEYWELL RS485