BBV Rx100 Interface Receiver
Addendum to manual for the following domes:
Videcon Dome
Rx100 software RX1_V4V2
Application Notes
The RX 100 provide the following functionality when controlling the above mentioned dome
Variable speed Pan/Tilt.
16 Full scene presets.
2 RX100 preset patrols.
Pattern Tour 1 learn and playback using AUTOPAN Privacy zone support
IR Filter CUT using LIGHTS is link
Advanced Features | Tx400 | Tx1000 | Tx1500 | DM DS/DS2/BX2 Mux |
|
Display MENU | ‘#’ 1 | '#' WASH | 1 ’#’ | *889 002 or *889 10 10 2 | |
Display Privacy Menu | ‘#’ 2 | '#' WIPE | 2 ’#’ | *889 003 or *889 10 10 3 | |
Record Pattern Tour 1 | ‘#’ 3 | '#' AUTOPAN | 3 ’#’ | *889 004 or *889 10 10 4 | |
Stop Recording | ‘#’ 4 | ‘#’ LIGHTS | 4 ‘#’ | *889 005 or *889 10 10 5 |
Pattern Tour 1 playback = press AUTOPAN
The dome and Rx100 are linked using RS485 for control and video for the camera signal.
Rx100 | Description | Dome connection |
| D- | |
TX+/A | D+ |
Notes:
The dome switches must be as follows to select Pelco P, 9600 baud and address 1.
SW1, 1 ON,
The alarm output relay opens for approx 5 seconds upon power up and following any active alarm input.
When navigating the dome’s menu or privacy setup use the joystick and IRIS OPEN and CLOSE. The dome manual has detailed information on the menu structure and privacy setting.
J6 Links