Sony RX100 manual Rx+, # Autopan, DAY Night Mode, ‘#’ Lights

Page 15

BBV Rx100 Interface Receiver

Addendum to manual for the following domes:

Borsatec BT2790FF Dome

Rx100 software RX1_B3V2

Application Notes

The RX100 provides the following functionality when controlling the above mentioned dome:

Variable speed Pan/Tilt.

16 Full scene presets.

2 RX100 preset patrols. Pattern 1 learn and playback 2 preset patrols.

4 alarm inputs moving to preset 1 - 4

Additional commands:

Advanced Features

Tx400

Tx1000

Tx1500

DM DS/DS2/BX2 Mux

Dome MENU

‘#’ 1

'#' WASH

1 ’#’

*889 002 or *889 10 10 2

(Preset 95)

 

 

 

 

Start Patten 1

‘#’ 2

'#' WIPE

2 ’#’

*889 003 or *889 10 10 3

(Preset 81)

 

 

 

 

B L C. On OFF

‘#’ 3

'#' AUTOPAN

3 ’#’

*889 004 or *889 10 10 4

(Preset 93)

 

 

 

 

DAY NIGHT MODE

‘#’ 4

‘#’ LIGHTS

4 ‘#’

*889 005 or *889 10 10 5

(Preset 152)

 

 

 

 

AUTOPAN calls scan - goto preset 66

LIGHTS operates the dome AUX 1 relay - goto preset 94

WIPER Disabled

WASH Disabled

RS485 control of dome using the following connections:

Rx100

Description

Dome

J3-C1 TX/RX-

Data-

RX -

J3-C2 TX/RX+

Data+

RX+

Notes:

The alarm output relay opens for approx 5 seconds upon power up. This can be used to signal power loss, etc.

Set the Dome address to 1, SW1 1 ON, 2-8 OFF

Protocol - Protocol and Baud, SW2 1-7 OFF, 8 ON, Pelco D - 2400 Baud

Shorting the TEST link after power up will pan the dome LEFT and ZOOM IN. Releasing the short will stop pan and zoom out. This is allows confirmation of correct wiring and switch settings at the dome.

Link J6/3-4 – Dome enters preset patrol after 5minutes of inactivity. Link J6/4-5 disabled.

Rx100 installation manual V1.17 29 Aug 08.doc

Page 15

Image 15 Contents
Installation Guide Table of Contents Unpacking Important Safety PrecautionsRx100 installation manual V1.17 29 Aug 08.doc RX100/WBX GeneralTx300 Tx400 Tx400DC Tx1000 Tx1000DC Tx1500 Transmitter Compatability ChartCable Connection Method Operating Voltage Function Connector TypeVideo Launch Amplifier and Cable Length Compensation Diagnostic AidsRx100 Rx200 Rx300 Rx400P Rx400DC Rx45X AC Rx55X DC Simple Single Camera System Appendix a Dome addendums & connection details BBV Rx100/24 Supply Additional information iss pcb BBV Rx100 Interface Receiver ‘#’ Lights DAY Night ModeRX+ # AutopanTX+ BBV Rx 100 Interface ReceiverDM/DS/DSL/DS2 Rx100 software RX1D4V7AUTO/MANUAL Focus Toggle Enable ALL SceneDisable ALL Scene Disable around Cursor# Wash TX+/A TX-/BTXDI+ # Autopan# Lights TxdiGreen TX/RXRED TX/RX+BBV Rx 100 Interface Receiver ENTRY/EXIT Dome Menu ‘#’ # Wash ’#’ Lights Wiper Washer DM-DSL/DS/DS2RX+ ‘#’ Autopan Using the advanced features when using a BBV Tx1000DCReset Dome DS/DSL/DS2/BX2Control from DM Digital Sprite 2 systems Using the advanced features when using a BBV Tx400DCTurn Menu Off *889 10 10 Menu Access when using a BBV Tx1000DCMenu Access when using a BBV Tx400DC Menu Access when using DM DS/DSL/DS2DM DS/DS2/BX2 J3/GND AUTO, INDOOR, Outdoor‘#’ Autopan ‘#’ LightsTX/RX+ TX/RXApplication Notes Privacy SET Toggle Mono/Colour ‘#’ # Wipe ’#’ TX/RX+ Comm IN+ AUX1AUX2 TX/RX Comm’#’ 889 004 or *889 10 10 Stop Recording ‘#’ Protocol P/D RS485 B Appendix B Trouble shooting guide Blank for your notes Dennard RS485 PHILIPS/BOSCH RS485 Optional BI-PHASE InputPelco P/D RS485 VCL/HONEYWELL RS485