Sony RX100 manual Diagnostic Aids, Video Launch Amplifier and Cable Length Compensation

Page 9

4. SETUP

DIAGNOSTIC AIDS

Two red LEDs and one Green LED are mounted on-board to give simple system status information. Their functions are as follows:

Cable LED

Regular Blinking- Blinking but mainly ON Blinking but mainly OFF

Error LED

On

Both LEDs

Off

Data LED (Iss PCB 4 onwards only) is

Test Link

Telemetry and video signals are OK.

-No Telemetry from the transmitter.

-No video from the camera.

-Telemetry transmission error.

-No power or major PCB fault.

- Will flash on and off very fast when data being sent to the dome.

-Is used to confirm correct operation of the

Rx100 and dome and also that the RS485 connection is correct. Shorting the link after the Rx100 is powered up will cause the dome to pan left and zoom in. Removing the link will stop the pan left and will zoom out the lens. This is dependant on dome type.

All BBV equipment is designed to auto-tune and compensate for any discrepancies in the transmitted telemetry signal; there are no further adjustments that need to be made.

VIDEO LAUNCH AMPLIFIER AND CABLE LENGTH COMPENSATION

The interface features a video launch amplifier with two variable controls situated close to the BNC connectors: Lift and Gain. These are pre-adjusted for a cable distance of 500m of CT125, and are adjustable to compensate for video detail or signal losses if and when longer or shorter cable lengths are used to connect the telemetry transmitter to the interface.

Fig. 3 Launch Amplifier

HF Lift

Gain

CAMERA

Video

LIFT

from

dome

 

GAIN

 

Video

to

transmitter

TELEMETRY

The purpose of each control is:

GAIN

varies the overall signal level.

LIFT

boosts the high frequency component of the video

signal. If the high frequency component is too low, picture appears ‘washed out’ and lacking detail.

Default position adjusted for 500M of CT125.

For shorter cable lengths, turn the Gain control anti-clockwise until 1V p-p is present at the telemetry transmitter. For longer cable lengths, turn the Gain control clockwise until 1V p-p is present at the telemetry transmitter.

Rx100 installation manual V1.17 29 Aug 08.doc

Page 9

Image 9 Contents
Installation Guide Table of Contents Unpacking Important Safety PrecautionsRx100 installation manual V1.17 29 Aug 08.doc RX100/WBX GeneralTx300 Tx400 Tx400DC Tx1000 Tx1000DC Tx1500 Transmitter Compatability ChartCable Connection Method Operating Voltage Function Connector TypeVideo Launch Amplifier and Cable Length Compensation Diagnostic AidsRx100 Rx200 Rx300 Rx400P Rx400DC Rx45X AC Rx55X DC Simple Single Camera System Appendix a Dome addendums & connection details BBV Rx100/24 Supply Additional information iss pcb BBV Rx100 Interface Receiver RX+ DAY Night Mode# Autopan ‘#’ LightsTX+ BBV Rx 100 Interface ReceiverDM/DS/DSL/DS2 Rx100 software RX1D4V7Disable ALL Scene Enable ALL SceneDisable around Cursor AUTO/MANUAL Focus Toggle# Wash TX+/A TX-/B# Lights # AutopanTxdi TXDI+RED TX/RXTX/RX+ GreenBBV Rx 100 Interface Receiver ENTRY/EXIT Dome Menu ‘#’ # Wash ’#’ Lights Wiper Washer DM-DSL/DS/DS2RX+ Reset Dome Using the advanced features when using a BBV Tx1000DCDS/DSL/DS2/BX2 ‘#’ AutopanControl from DM Digital Sprite 2 systems Using the advanced features when using a BBV Tx400DCMenu Access when using a BBV Tx400DC Menu Access when using a BBV Tx1000DCMenu Access when using DM DS/DSL/DS2 Turn Menu Off *889 10 10DM DS/DS2/BX2 ‘#’ Autopan AUTO, INDOOR, Outdoor‘#’ Lights J3/GNDTX/RX+ TX/RXApplication Notes Privacy SET Toggle Mono/Colour ‘#’ # Wipe ’#’ AUX2 AUX1TX/RX Comm TX/RX+ Comm IN+’#’ 889 004 or *889 10 10 Stop Recording ‘#’ Protocol P/D RS485 B Appendix B Trouble shooting guide Blank for your notes Pelco P/D RS485 PHILIPS/BOSCH RS485 Optional BI-PHASE InputVCL/HONEYWELL RS485 Dennard RS485