Dell E600I manual SFM and RPM Power Requirements, Agency Compliance

Page 67

SFM and RPM Power Requirements

Module

Power Requirement in Watts (in BTUs)

 

 

SFM

60W (210 BTU/hour)

RPM

150W (510 BTU/hour)

 

 

Agency Compliance

The E600i is designed to comply with the following safety and agency requirements.

USA Federal Communications Commission (FCC) Statement

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designated to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy. If it is not installed and used in accordance to the instructions, it may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case users will be required to take whatever measures necessary to correct the interference at their own expense.

Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits. Dell Force10 is not responsible for any radio or television interference caused by using other than recommended cables and connectors or by unauthorized changes or modifications in the equipment. Unauthorized changes or modification could void the user’s authority to operate the equipment.

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Canadian Department of Communication Statement

European Union EMC Directive Conformance Statement

This product is in conformity with the protection requirements of EU Council Directive 2004/108/EC on the approximation of the laws of the Member States relating to electromagnetic compatibility. Dell Force10 can not accept responsibility for any failure to satisfy the protection requirements resulting from a non-recommended modification of this product, including the fitting of non-Dell Force10 option cards.

This product has been tested and found to comply with the limits for Class A Information Technology Equipment according to CISPR 22/ European Standard EN 55022. The limits for ClassA equipment were derived for commercial and industrial environments to provide reasonable protection against interference with licensed communication equipment.

WARNING: This is a Class A product. In a domestic environment, this device may cause radio interference, in which case, the user may be required to take adequate measures.

European Community Contact

Dell Force10, EMEA - Central Dahlienweg 19

66265 Heusweiler Germany

http://www.force10networks.com/german/ Tel: +49 172 6802630

Email: EMEA Central Sales

System Specifications

67

Image 67
Contents E600i TeraScale Installation Guide Page Contents Powering Up System Boot W . d e l l . c o m s u p p o r t . d e l l . c o m Contents About This Guide Information Symbols and Warnings1describes symbols contained in this guide Information SymbolsRelease Notes for the E-Series Related PublicationsSite Selection Site PreparationEquipment Rack and Cabinet Requirements Storage Requirements Power Requirements2500W AC Power Requirements DC Power RequirementsOperating Overview E600i SystemE600i Chassis Rear View E600i Chassis Front View with AC Power SuppliesE600i Hardware Component Operating Requirements Summary E600i System Installation ProcessPage Installing the Equipment Rack Shelf Bar Installing the ChassisUnpacking the E600i System Standard Front Chassis Rack Mounting To install a equipment rack shelf barTo install the chassis into a prepared rack Installing the Chassis into an Equipment CabinetPage Fan Tray Installing the Fan TrayFan Speed Fan Speed and TemperatureMinimum Power Supply Requirements Power SupplyAC Power Supply Unit AC Power Supply UnitsInstall the AC Power Supply Units Power Cord RequirementsTo install an AC power supply unit To remove an AC power supply unit Remove the AC Power SupplyTo install a DC PEM DC Power Entry ModulesCable and Connector Requirements Install the DC PEMsReplace the DC PEM Removing the DC PEM Safety CoverTo remove a PEM Page RPMs Installing RPMs, Line Cards, and SFMsUnpacking Line Cards and RPMsBlank Panels Preparing and Installing the RPMs and Line CardsTo install line cards and RPMs Line CardsInstalling RPM into the E600i RPM Label and LEDs Installing a Second RPMRPM LEDs Line Card LEDs Installing Switch Fabric Modules SFMsInstalling SFMs 2defines the SFM front panel and LED displays SFM Front Panel and LEDsSFM Front Panel and LED Descriptions Page RPM Ports and Cables Connecting the Console and Auxiliary PortsRPM Ports Console Port RJ-45 Pin Assignments Cable and Adapter Pin AssignmentsAuxiliary Port RJ-45 Pin Assignments Accessing the Console with a DB-25 Adapter Accessing the Console with a DB-9 AdapterPin Assignments Between E600i Console and DB-25 Adapter 100 Ethernet Management Port LEDs Accessing the 10/100 Ethernet Management PortAccessing the Auxiliary Port by Modem RJ-45 to DB-25 Adapter Pin Modem AssignmentsPreparation Powering UpSupplying Power To supply power to the E600i systemBooting from the Bootuser Prompt Booting to the CLI PromptRemoving and Replacing the Fan Tray Removing and Replacing PartsReplacing 2500W AC Power Supply Removing and Replacing Power ModulesReplacing DC PEMs Removing the Power CordDC PEM Label Removing and Replacing RPMs, Line Cards, or SFMsNo linecard number To remove and install an SFMReplacing the E600i Air Filter Removing and Replacing the Air FilterTo remove and replace the air filter Page Removing the External Flash Memory Card Using a Flash Memory CardExternal Flash Memory Card Overview Inserting the External Flash Memory CardCopying Files to the External Flash Formatting an External Flash CardDisplaying Files Stored on the External Flash Dir Command Example Page E600i System Boot Process System BootBooting from the Bootuser Prompt Help To configure the chassis from the Bootuser promptUse the boot change command to edit appropriate fields Show default-gateway default-gateway ip-address Force10 Page Table B-1. Alarm Events and Reporting AlarmsSFMs and Alarms AC Power Supplies and AlarmsAlarms Alarms W . d e l l . c o m s u p p o r t . d e l l . c o m Chassis Physical Design System SpecificationsThis appendix contains the following major sections DC Power Entry Module Requirement AC Power Supply Unit RequirementsEnvironmental Agency Compliance SFM and RPM Power RequirementsJapan Vcci Compliance for Class a Equipment Electromagnetic Compatibility EMC Safety Standards and Compliance Agency CertificationsProduct Recycling and Disposal Figure C-1. The European Weee symbol This appendix contains these major sections Accessing iSupport ServicesTechnical Support ISupport WebsiteRequest tab Contacting the Technical Assistance CenterTo request replacement hardware, follow these steps Requesting a Hardware ReplacementPage Page W. d e l l . c o m s u p p o r t . d e l l . c o m

E600I specifications

The Dell E600i stands as a robust and versatile solution in the realm of high-performance computing, designed to meet the demands of both enterprise environments and individual users. This workstation is characterized by its powerful processing capabilities, advanced graphics options, and extensive customization features that allow users to tailor the system to fit specific needs.

At the heart of the Dell E600i is its support for the latest multi-core processors, offering substantial performance for demanding applications, whether in data analysis, 3D modeling, or intensive computational tasks. Users can choose from a range of Intel Xeon or Core processors, ensuring that they can achieve optimal performance levels according to their workload requirements.

In terms of graphics, the E600i provides the option to integrate high-performance GPU selections from NVIDIA or AMD. This makes it particularly suitable for graphic design, video editing, and complex simulations. The inclusion of dedicated graphics cards not only enhances rendering capabilities but also supports advanced visualization technologies, which are essential for industries such as architecture, engineering, and media production.

One of the standout characteristics of the E600i is its expandability. With multiple expansion slots available, users can easily upgrade or integrate additional components to enhance performance or to adapt to new tasks. This system supports ample memory configurations, allowing for significant multitasking and overall system responsiveness.

In addition to its hardware capabilities, the Dell E600i leverages cutting-edge technologies to enhance usability and performance. Features such as Dell Precision Optimizer streamline workflow by automatically adjusting settings to optimize the performance of specific applications. Furthermore, Dell’s reliability in terms of build quality and support ensures that users can rely on their workstation for long durations without concern.

The E600i is also engineered with an eco-friendly focus, incorporating energy-efficient technologies that not only reduce operating costs but also minimize environmental impact. This attention to sustainability makes it an attractive option for businesses and professionals committed to responsible practices.

In conclusion, the Dell E600i is a high-performance workstation that brings together powerful processing, advanced graphics capabilities, and exceptional expandability. Its robust features and focus on usability make it a compelling choice for professionals in numerous fields, ensuring that they can tackle any project with confidence and ease.