Dell E600I manual RPM Label and LEDs, Installing a Second RPM, RPM LEDs

Page 32

w w w . d e l l . c o m s u p p o r t . d e l l . c o m

Installing a Second RPM

Install a second RPM either before the system is powered on or after the Primary RPM is up and stable. After the second RPM is installed, wait several seconds until the connection between the two RPMs is established before configuring any commands. Below is an example of the messages that appear:

%POLLMGR-2-ALT_RPM_STATE: Alternate RPM is present

%IRC-6-IRC_COMMUP: Link to peer RPM is up

%RAM-6-RAM_TASK: RPM1 is in Standby State.

Once the link between the two RPMs is established, copy the running configuration to the startup configuration.

RPM Label and LEDs

Table 7-1describes the RPM LED states and the RPM front panel.

RPMs control the routing and switching functions for the entire E600i system. The E600i operates with a minimum of one RPM module. You can hot-insert a second RPM into a running system without performance interruption or software intervention. A second RPM for redundant functionality provides uninterrupted operability if the system transitions from the primary RPM to the secondary (standby) RPM. The secondary RPM constantly performs updates and receives the same information received by the primary RPM. The secondary RPM also performs diagnostics on its subsystems. In the event of a switchover, the secondary RPM immediately takes over and resumes the control activities that the primary RPM was performing.

Table 7-1. RPM LEDs

Section

Label

Description

 

 

 

Management

10/100

L: Green: link is up

 

Ethernet

A: Green: activity on port

 

 

 

Alarms

Major

Red: a critical condition exists, such as a severe over temperature condition, a fan tray

 

 

failure, an over temperature condition in a power supply, or an out-of-tolerance voltage.

 

 

The RPM LEDs are controlled by software which sets the threshold levels for triggering the

 

 

different stages of alarms.

 

 

Unlit: no major conditions.

 

 

 

 

Minor

Amber: a serious condition exists, such as an over temperature condition, a single fan failure,

 

 

or a line card failure. The RPM LEDs are controlled by software, which sets the threshold

 

 

levels for triggering the different stages of alarms.

 

 

Unlit: no minor alarm conditions.

 

 

 

 

ACO/LT

Allows you to test the operability of LEDs to verify that they are able to light.

 

 

Press the ACO/LT button to temporarily illuminate the LEDs on the RPM.

 

 

If you press this button when the alarm status LED is lit, the alarm relay contacts are reset

 

 

until the next alarm event.

32 Installing RPMs, Line Cards, and SFMs

Image 32
Contents E600i TeraScale Installation Guide Page Contents Powering Up System Boot W . d e l l . c o m s u p p o r t . d e l l . c o m Contents Information Symbols and Warnings 1describes symbols contained in this guideInformation Symbols About This GuideRelated Publications Release Notes for the E-SeriesEquipment Rack and Cabinet Requirements Site PreparationSite Selection Power Requirements 2500W AC Power RequirementsDC Power Requirements Storage RequirementsE600i System Operating OverviewE600i Chassis Front View with AC Power Supplies E600i Chassis Rear ViewE600i System Installation Process E600i Hardware Component Operating Requirements SummaryPage Unpacking the E600i System Installing the ChassisInstalling the Equipment Rack Shelf Bar To install a equipment rack shelf bar Standard Front Chassis Rack MountingInstalling the Chassis into an Equipment Cabinet To install the chassis into a prepared rackPage Installing the Fan Tray Fan TrayFan Speed and Temperature Fan SpeedPower Supply Minimum Power Supply RequirementsAC Power Supply Units AC Power Supply UnitTo install an AC power supply unit Power Cord RequirementsInstall the AC Power Supply Units Remove the AC Power Supply To remove an AC power supply unitDC Power Entry Modules Cable and Connector RequirementsInstall the DC PEMs To install a DC PEMRemoving the DC PEM Safety Cover Replace the DC PEMTo remove a PEM Page Installing RPMs, Line Cards, and SFMs UnpackingLine Cards and RPMs RPMsPreparing and Installing the RPMs and Line Cards To install line cards and RPMsLine Cards Blank PanelsInstalling RPM into the E600i RPM LEDs Installing a Second RPMRPM Label and LEDs Installing Switch Fabric Modules SFMs Line Card LEDsInstalling SFMs SFM Front Panel and LED Descriptions SFM Front Panel and LEDs2defines the SFM front panel and LED displays Page RPM Ports Connecting the Console and Auxiliary PortsRPM Ports and Cables Auxiliary Port RJ-45 Pin Assignments Cable and Adapter Pin AssignmentsConsole Port RJ-45 Pin Assignments Pin Assignments Between E600i Console and DB-25 Adapter Accessing the Console with a DB-9 AdapterAccessing the Console with a DB-25 Adapter Accessing the 10/100 Ethernet Management Port Accessing the Auxiliary Port by ModemRJ-45 to DB-25 Adapter Pin Modem Assignments 100 Ethernet Management Port LEDsPowering Up Supplying PowerTo supply power to the E600i system PreparationBooting to the CLI Prompt Booting from the Bootuser PromptRemoving and Replacing Parts Removing and Replacing the Fan TrayRemoving and Replacing Power Modules Replacing 2500W AC Power SupplyRemoving the Power Cord Replacing DC PEMsRemoving and Replacing RPMs, Line Cards, or SFMs DC PEM LabelTo remove and install an SFM No linecard numberRemoving and Replacing the Air Filter Replacing the E600i Air FilterTo remove and replace the air filter Page Using a Flash Memory Card External Flash Memory Card OverviewInserting the External Flash Memory Card Removing the External Flash Memory CardDisplaying Files Stored on the External Flash Formatting an External Flash CardCopying Files to the External Flash Dir Command Example Page Booting from the Bootuser Prompt System BootE600i System Boot Process To configure the chassis from the Bootuser prompt HelpUse the boot change command to edit appropriate fields Show default-gateway default-gateway ip-address Force10 Page Alarms Table B-1. Alarm Events and ReportingAC Power Supplies and Alarms SFMs and AlarmsAlarms Alarms W . d e l l . c o m s u p p o r t . d e l l . c o m This appendix contains the following major sections System SpecificationsChassis Physical Design Environmental AC Power Supply Unit RequirementsDC Power Entry Module Requirement SFM and RPM Power Requirements Agency ComplianceJapan Vcci Compliance for Class a Equipment Product Recycling and Disposal Safety Standards and Compliance Agency CertificationsElectromagnetic Compatibility EMC Figure C-1. The European Weee symbol Accessing iSupport Services Technical SupportISupport Website This appendix contains these major sectionsContacting the Technical Assistance Center Request tabRequesting a Hardware Replacement To request replacement hardware, follow these stepsPage Page W. d e l l . c o m s u p p o r t . d e l l . c o m

E600I specifications

The Dell E600i stands as a robust and versatile solution in the realm of high-performance computing, designed to meet the demands of both enterprise environments and individual users. This workstation is characterized by its powerful processing capabilities, advanced graphics options, and extensive customization features that allow users to tailor the system to fit specific needs.

At the heart of the Dell E600i is its support for the latest multi-core processors, offering substantial performance for demanding applications, whether in data analysis, 3D modeling, or intensive computational tasks. Users can choose from a range of Intel Xeon or Core processors, ensuring that they can achieve optimal performance levels according to their workload requirements.

In terms of graphics, the E600i provides the option to integrate high-performance GPU selections from NVIDIA or AMD. This makes it particularly suitable for graphic design, video editing, and complex simulations. The inclusion of dedicated graphics cards not only enhances rendering capabilities but also supports advanced visualization technologies, which are essential for industries such as architecture, engineering, and media production.

One of the standout characteristics of the E600i is its expandability. With multiple expansion slots available, users can easily upgrade or integrate additional components to enhance performance or to adapt to new tasks. This system supports ample memory configurations, allowing for significant multitasking and overall system responsiveness.

In addition to its hardware capabilities, the Dell E600i leverages cutting-edge technologies to enhance usability and performance. Features such as Dell Precision Optimizer streamline workflow by automatically adjusting settings to optimize the performance of specific applications. Furthermore, Dell’s reliability in terms of build quality and support ensures that users can rely on their workstation for long durations without concern.

The E600i is also engineered with an eco-friendly focus, incorporating energy-efficient technologies that not only reduce operating costs but also minimize environmental impact. This attention to sustainability makes it an attractive option for businesses and professionals committed to responsible practices.

In conclusion, the Dell E600i is a high-performance workstation that brings together powerful processing, advanced graphics capabilities, and exceptional expandability. Its robust features and focus on usability make it a compelling choice for professionals in numerous fields, ensuring that they can tackle any project with confidence and ease.