$&5RXWLQJ&DEOH
The PowerEdge 6350 system is unique in that live AC power is routed inside the system. An AC routing cable (not the same cable as the AC power cable in the next section) connects to the power receptacle at the back of the system and runs along the inside of the left chassis wall to the PSPB (see Figure
WARNING: The PSPB in the PowerEdge 6350 system connects to live AC power via the AC routing cable. Before removing or servicing the system, it is critical to make certain that AC power is disconnected from the back of the system.
6HFXULQJWKH$&3RZHU&DEOH
To prevent accidental removal of the AC power cable from the power recepta- cle at the back of the chassis, a cable retainer maintains a slack loop that protects the connection. The retainer can be either a metal clip attached to the AC power receptacle (see Figure
AC power cable
)LJXUH(open)0HWDO | &DEOH |
metal securing clip |
|
For a system that uses the metal securing clip, before removing the AC power cable you must swivel the clip away from the cable as shown in Figure
5RXWLQJ,QWHUIDFH&DEOHV,QVLGHWKH&KDVVLV
The interface cables inside the chassis must be routed correctly to ensure that the fan assembly (positioned over the cables) has room to fit fully into the chassis. If you need to disconnect and remove any interface cables from the system board, be sure to reinstall the cables in the order shown in Table
System Overview |