Intermec manual Upgrading Your SF51, To upgrade the SF51

Page 31

Chapter 2 — Configuring and Managing the SF51

Upgrading Your SF51

When you upgrade your SF51, you update the SF51 processor firmware. The current settings are erased and replaced with the default settings for the SF51. You need to reestablish Bluetooth communications between your SF51 and other Bluetooth devices and applications in your data collection system.

To upgrade the SF51, you need these items:

SF51 firmware upgrade package:

SF51Upgrade.exe (SF51 Firmware Upgrade Utility)

SF51_01_01.ldr (firmware upgrade file)

readme.txt (upgrade instructions)

USB Bluetooth adapter (P/N 074892)

PC running Microsoft Windows 2000/XP with SP1 or SP2

To upgrade the SF51

1Download the latest upgrade package from the Intermec web site at www.intermec.com.

a Go to Service & Support > Downloads.

b From the Select A Product drop-down list, choose Bar Code Scanners: SF51 Cordless Scanner.

c Click the link to download the upgrade package, and save it to your PC.

2Fully charge the SF51 battery. For help, see “Charging the Battery” on page 4.

3Remove the SF51 from the charger.

4If necessary, install the USB Bluetooth adapter (P/N 074892) and create a Bluetooth connection between your SF51 and your PC. For help, see the USB Bluetooth Adapter Instructions (P/N 074479) that ship with the adapter.

Note: Make sure that all applications on your PC are closed.

5Start the SF51 Firmware Upgrade Utility.

SF51 Cordless Scanner User’s Guide

19

Image 31
Contents Users Guide Bluetooth is a trademark of Bluetooth SIG, Inc., U.S.A Version Date Description of Change Document Change RecordSF51 Cordless Scanner User’s Manual Contents Troubleshooting and Maintaining MSI Index Before You Begin Safety SummarySafety Icons Warranty Information Global Services and SupportWeb Support Telephone Support Related Documents Who Should Read This Document?Telephone Support Using the SF51 Introducing the SF51 Cordless Scanner To turn off the SF51 How to Turn On the SF51Using the Battery To turn on the SF51Understanding the Lights Charging the BatteryChecking the Battery Status To charge the batteryLight State What It Means Status Light DescriptionBeep Sequence What It Means Intermec Ready-to-Work Indicator DescriptionUnderstanding the Beeps SF51 Beeps DescriptionTo turn on vibrate alert Using Vibrate AlertTo turn off vibrate alert To scan a bar code label Scanning Bar CodesCollecting Data With Your SF51 To collect data using an Intermec computerTo collect data using a host PC Configuring and Managing the SF51 Configuring With EasySet How to Configure the SF51 ParametersTo configure the SF51 online with EasySet To configure the SF51 offline with EasySet Configuring From Your Intermec ComputerTo configure the SF51 from your Intermec computer Restoring Default SettingsTo restore default settings Configuring Security Configuring Bluetooth CommunicationsTo configure a Bluetooth PIN for your SF51 Configuring the Discoverable State of the SF51 Connecting the SF51 to a Host Device To configure your SF51 for limited discoverability Double-clickcompose BT address To connect to an Intermec computerTo disconnect from a host PC To connect to a host PC with the USB Bluetooth adapterUpgrading Your SF51 To upgrade the SF51To troubleshoot a locked up SF51 Troubleshooting the Firmware UpgradeConfiguring and Managing the SF51 Configuring and Managing the SF51 Troubleshooting Maintaining SF51 Getting Information About Your SF51 Troubleshooting the SF51Problem Problems and Possible SolutionsPossible Solution Problems and Possible Solution You try to scan a bar code, and nothing happens To page the SF51 Resetting the SF51To reset the SF51 Locating the SF51To clean the scanner window Cleaning the SF51Troubleshooting and Maintaining the SF51 Configuration Command Reference Using Configuration Commands Reset All Parameters Configuration Commands By FunctionData Transmission Settings Symbology Default Value See Symbology SettingsTrigger Activation Command Default Value See Operating SettingsData Decoding Security Command Default Value See Beep Duration SF51 Configuration CommandsAdministrator Reset Factory Defaults Configuration Modes and UtilitiesBluetooth Device Beep VolumeBluetooth Connect/Disconnect Bluetooth Device NameBluetooth Security Bluetooth DiscoverableBluetooth PIN Bluetooth ProfileCode CodabarCodablock a Codablock FIsbt Configuration Modes and UtilitiesCode 93/93i Code 128 / EANGood Read Beep Duration Disable All SymbologiesError Beep Consecutive Same Read Data ValidationMatrix 2 Good Read Beep TimingGood Read LED Duration Interleaved 2Postamble PlesseyPreamble RSS Limited Setup BeepRSS RSS ExpandedTelepen Symbology IdentifierTimeout Between Different Consecutive Codes Symbology Identifier OptionsMode Description Timeout Between Identical Consecutive CodesTrigger Mode Trigger Mode OptionsGtin Processing User Reset Factory DefaultsVibrate Alert Vibrate Alert DurationConfiguration Command Reference Appendix Temperature and Environmental Specifications SpecificationsPhysical Dimensions Power and Electrical SpecificationsCommunication Range Accessories for the SF51Bluetooth Radio Accessories for the SF51Accessories for the SF51 Index Numbers Index Index Index UPC/EAN Described, 6 illustration, 5 telephone support Bluetooth PIN, 15 configuring, 15 discoverable state SF51 Index Index SF51 Cordless Scanner User’s Guide Page 074474-003