I-O Display Systems Basic I/O Product Specifications, Ordering Information, Position Basic I/O AD

Page 53

Introduction 1

Specifications

Network Communications:

duTec supports two standards for transmitting serialized I/O data between the host computer and the BASIC I/O ADs at baud rates to 38,400.

 

 

 

 

Maximum Distance

 

 

 

 

 

 

 

 

 

 

 

Serial Link

Feet

Meters

 

 

 

 

 

 

 

 

 

 

 

RS-422 /485

5,000

1,524

 

 

 

 

 

 

 

 

 

 

Physical Characteristics:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power

 

Supply

 

 

5Vdc@<5A

 

 

 

 

 

 

 

 

 

 

Environment

 

Temperature

 

 

0-60 C

 

 

 

 

 

 

 

 

 

 

 

 

Humidity

 

 

95% Non-Condensing

 

 

 

 

 

 

 

 

 

 

Options

 

/L

 

 

Local Control

 

 

 

 

 

 

 

Function (LCF)

Ordering Information

Specify duTec products by model number, e.g.,

BIO4AD

4 Position BASIC I/O AD

 

 

BIO8AD

8 Position BASIC I/O AD

 

 

BIO16AD

16 Position BASIC I/O AD

 

 

Options are specified by a series of suffixes to the model number, preceded by a slash for example:

BIO8AD/L

1-7(Vol.2)

Image 53
Contents Page Basic I/O Product Family Page Vol.1 Table of Contents Vol Table of Contents Basic I/O Basic I/OAnalog input instruction types are Analog InputsAnalog Outputs Digital Inputs Digital Outputs Throughput Tables System Throughput7Vol.1 Communication Protocol Analog INPUTS, 12 BIT Analog OUTPUTS, 12 BIT Physical Characteristics DiagnosticsBasic I/O Models Product Test12Vol.1 Mounting Setup & Installation+5V GND Power WiringCommunicating with the Basic I/O Repeat RS-485 can only be multidropRS-485 RS-422RS-485 Programming Communication Wiring Network Bias Resistor Locations Network load V.S. Noise suppressionRS-422 Host to Basic I/O RS-422 Host to Basic I/O wiringRS-422 Basic I/O-To-BASIC I/O multidrop Basic I/O to Basic I/O RS-422 Multidrop or RepeaterRS-485 To-BASIC I/O RS-485 Host to Basic I/ORS-485 Basic I/O to Basic I/O Multidrop Basic I/O to Basic I/O RS-485 Multidrop onlyBasic I/O Connectors, Switches and Indicators Basic I/O setupBaud Rates Analog/ DigitalAddresses Protocol Handshake Types L1 Repeater Network Type SwitchL2 Multidrop L3 Last UnitU1=00 H096 L3 P2 Setup via PushbuttonCommunication verification Error Code Hardware error codesOther error codes Sensor/ Actuator I/O wiringAnalog Inputs 10 AC Current and Voltage Wiring11 Analog Voltage and Current input Wiring Analog outputs 13 Analog Voltage and Current Output WiringDigital Inputs 14 Digital Input WiringDigital Outputs 15 Digital Output WiringAnalog Outputs Vol.1 IndexPage Basic I/O AD Vol Table of Contents Basic I/O AD to Basic I/O AD RS-422 Product Test IntroductionCapacity Signal compatibility Protocol Compatibility Offsets TemperatureGain/ Slope Range LimitsDigital inputs Read DelayedPulse widths Pulse countingExtended capabilities SquarewavePulse Generator Ordering Information SpecificationsPosition Basic I/O AD BIO8AD/L8Vol.2 Installation InstallationPower Wiring Multidrop Designing the NetworkRS-422 RS-485 Programming Communication Wiring Network Bias resistor locations Basic I/O AD Connectors, Switches and Indicators Network Type SwitchesLast Unit RS-422 Host to Basic I/O AD Communications WiringRS-485 To-BASIC I/O AD RS-485 Host to Basic I/O ADRS-422 Basic I/O AD-To-BASIC I/O AD Basic I/O AD to Basic I/O AD RS-422RS-485 Basic I/O AD to Basic I/O AD Basic I/O AD to Basic I/O AD RS-485Basic I/O AD Module Placement Worksheet Installing the I/O modules11 AC current and voltage wiring Module Wiring Analog Inputs12 Analog Voltage, frequency and Current input Wiring 14 Analog Voltage and Current Output Wiring 15 Digital Input Wiring 16 Digital output wiring Chassis Setup SetupOffset Mode Function addressesVariable Mode Baud Rates Changing Setup Parameters Via Pushbutton Communication Verification Hardware error codes Vol.2 Index Vol.2 Index