I-O Display Systems Basic I/O Product manual Hardware error codes

Page 79

Setup 3

Hardware error codes:

When the BASIC I/O AD is initially turned on it goes through internal self testing. If anything is not correct, the appropriate error code will flash on the sequential display. Try cycling power, if that does not resolve the error condition please call duTec technical support at 800-248-1632.

3-6(Vol.2)

Image 79
Contents Page Basic I/O Product Family Page Vol.1 Table of Contents Vol Table of Contents Basic I/O Basic I/OAnalog input instruction types are Analog InputsAnalog Outputs Digital Inputs Digital Outputs Throughput Tables System Throughput7Vol.1 Communication Protocol Analog INPUTS, 12 BIT Analog OUTPUTS, 12 BIT Physical Characteristics DiagnosticsBasic I/O Models Product Test12Vol.1 Mounting Setup & Installation+5V GND Power WiringCommunicating with the Basic I/O Repeat RS-485 can only be multidropRS-485 RS-422RS-485 Programming Communication Wiring Network Bias Resistor Locations Network load V.S. Noise suppressionRS-422 Host to Basic I/O RS-422 Host to Basic I/O wiringRS-422 Basic I/O-To-BASIC I/O multidrop Basic I/O to Basic I/O RS-422 Multidrop or RepeaterRS-485 To-BASIC I/O RS-485 Host to Basic I/ORS-485 Basic I/O to Basic I/O Multidrop Basic I/O to Basic I/O RS-485 Multidrop onlyBasic I/O Connectors, Switches and Indicators Basic I/O setupAddresses Analog/ DigitalBaud Rates Protocol Handshake Types L3 Last Unit Network Type SwitchL1 Repeater L2 MultidropU1=00 H096 L3 P2 Setup via PushbuttonCommunication verification Sensor/ Actuator I/O wiring Hardware error codesError Code Other error codesAnalog Inputs 10 AC Current and Voltage Wiring11 Analog Voltage and Current input Wiring Analog outputs 13 Analog Voltage and Current Output WiringDigital Inputs 14 Digital Input WiringDigital Outputs 15 Digital Output WiringAnalog Outputs Vol.1 IndexPage Basic I/O AD Vol Table of Contents Basic I/O AD to Basic I/O AD RS-422 Capacity IntroductionProduct Test Signal compatibility Protocol Compatibility Range Limits TemperatureOffsets Gain/ SlopePulse counting DelayedDigital inputs Read Pulse widthsPulse Generator SquarewaveExtended capabilities BIO8AD/L SpecificationsOrdering Information Position Basic I/O AD8Vol.2 Installation InstallationPower Wiring Multidrop Designing the NetworkRS-422 RS-485 Programming Communication Wiring Network Bias resistor locations Basic I/O AD Connectors, Switches and Indicators Network Type SwitchesLast Unit RS-422 Host to Basic I/O AD Communications WiringRS-485 To-BASIC I/O AD RS-485 Host to Basic I/O ADRS-422 Basic I/O AD-To-BASIC I/O AD Basic I/O AD to Basic I/O AD RS-422RS-485 Basic I/O AD to Basic I/O AD Basic I/O AD to Basic I/O AD RS-485Basic I/O AD Module Placement Worksheet Installing the I/O modules11 AC current and voltage wiring Module Wiring Analog Inputs12 Analog Voltage, frequency and Current input Wiring 14 Analog Voltage and Current Output Wiring 15 Digital Input Wiring 16 Digital output wiring Function addresses SetupChassis Setup Offset ModeVariable Mode Baud Rates Changing Setup Parameters Via Pushbutton Communication Verification Hardware error codes Vol.2 Index Vol.2 Index