Dell C5220 owner manual Server Platform Setup Utility Screens, Conventions

Page 21

Server Platform Setup Utility Screens

Conventions

The following typographical conventions are used in the tables:

The text and values in the Setup Item, Options, and Help columns in the tables are displayed on the BIOS Setup screens.

Text marked with an * in the Settings column of the tables indicates default values. These values are not displayed with an * on the setup screen. The marked text in this document is to serve as a reference point.

The Comments column provides additional information where it may be helpful. This information does not appear in the BIOS Setup screens.

Information in the screen shots that is enclosed in brackets (< >) indicates variables, depending on the option(s) installed. For example <Current Date> is replaced by the actual current date.

Information that is enclosed in square brackets ([ ]) in the tables indicates areas where the user needs to type in text instead of selecting from a provided option.

Whenever information is changed (except Date and Time) the systems requires a save and reboot to take place. Pressing <ESC> discards the changes and boot the system according to the boot order set from the last boot.

Using the System Setup Program

21

Image 21
Contents Dell PowerEdge C5220 Systems Regulatory Model B04S Important Information Page Contents 119 111About Your System Features Front-Panel Features and IndicatorsFeature Description Feature Status Description IndicatorsFeature Status Description About Your System About Your System About Your System About Your System About Your System Start Menu Using the System Setup ProgramBios Setup Options at Boot Enable/Disable Console RedirectionConsole Redirection Key Ansi Escape Sequence Other Sequences Configuring Special KeysGeneral Help Conventions Server Platform Setup Utility ScreensMain Main MenuDisplays the processor type Advanced Advanced MenuPower Management CPU Configuration Advanced\CPU ConfigurationState Disabled EnabledAll Prefetch Configuration Enable Advanced\CPU Configuration\Prefetch ConfigurationAdvanced\Memory Configuration Memory ConfigurationDisable AutoAdvanced\SATA Configuration Sata ConfigurationDrive Port Mapping of Cougar Point Sata Controllers PCI Configuration Advanced\PCI ConfigurationOnboard Gen2 Advanced\PCI Configuration\Embedded Network Devices Enabled with PXEEmbedded Network Devices Enabled without PXE Active State Power Management ConfigurationL0s & L1 Advanced\PCI Configuration\PCI Slot Configuration PCI Slot ConfigurationAdvanced\USB Configuration USB ConfigurationUSB Port with BMC Disabled Server Management Server ManagementMenu Fields Settings Comments Server Management/BMC Network Configuration Set BMC LAN ConfigurationIP Address Xxx.xxx.xxx.xxx Enter IP address Form Server/Remote Access Configuration Remote Access ConfigurationPost View System Event Log Using the System Setup Program Boot Boot MenuBios Security Security MenuSave & Exit Save and ExitCD/DVD ROM Post Error Handling Error MessagesStatus Codes Status Codes Status Code Description Command Line Interfaces for Setup options Recommended Tools Safety MeasuresInside the System Inside the SystemPowerEdge C5220 8-Sled SKU Sled ConfigurationRemoving a Sled SledsInstalling a Sled Supported Dimm Configuration Memory ModulesDimm Population Rules Supported Memory Supported MemoryDDR3 ECC VLP Removing a Memory Module Removing and Installing a Memory ModuleReplacing a Memory Module Removing a 2.5-inch Hard Drive Hard DrivesHDD2 HDD3 Installing a 2.5-inch Hard Drive Removing a 3.5-inch Hard Drive Remove the hard drive cables from the cable clips Installing a 3.5-inch Hard Drive Insert the hard drive cables into the cable clips Removing a 2.5-inch Hard Drive Board Hard Drive BoardsRemoving a 3.5-inch Hard Drive Board Installing a 2.5-inch Hard Drive BoardInstalling a 3.5-inch Hard Drive Board Removing a Heat Sink/Shroud Heat SinksRemoving a heat sink/shroud Installing a heat sink/shroud Installing a Heat Sink/ShroudFinal installed view of a heat sink/shroud Removing a heat sink Removing a Heat Sink10. Installing a heat sink Installing a Heat SinkRemoving a Processor ProcessorsInstalling a Processor Installing a 1 GbE and 10 GbE Mezzanine Card Mezzanine CardsReplacing a Mezzanine Card Optional 11. Installing a Linking Board in a Mezzanine Card Removing a 1 GbE and 10 GbE Mezzanine Card 13. Securing a Mezzanine AssemblyRemove the card from the assembly 16. Inserting a Linking Board in a SAS Mezzanine Card Installing a SAS Mezzanine Card with 2.5 HDD17. Installing a SAS Mezzanine Assembly in a Sled Removing a SAS Mezzanine Card with 2.5 HDD Routing the 2.5 SAS Mezzanine Cables19. Removing a SAS Mezzanine Assembly in a Sled 20. Removing a SAS Mezzanine Card Installing a SAS Mezzanine Card with 3.5 HDD21. Inserting a Linking Board on a 3.5 SAS Mezzanine Card Routing the 3.5 SAS Mezzanine Cables Removing a SAS Mezzanine Card with 3.5 HDDSAS Cable Identification 24 .5 SAS Cable SAS CableTroubleshooting Sequence Server Boot IssuesSystem Does Not Boot After Initial Installation Product Family 100101 102 System Does Not Boot After Configuration Changes103 Installation ProblemsTroubleshooting External Connections Update UtilitiesBMC Firmware Update Firmware Recovery Utility-SOCFLASH Utility105 106 Updates Through TFTP/HTTP/FTP107 108 Bios Recovery Mode Bios System UpdateFirmware Update Utility-AMI Flash Utility Bios Recovery Flow110 111 System Board Jumpers and ConnectorsJP5 112113 Inch Hard Drive Board ConnectorsBackplane Connectors Sled Backplane Front Connectors114 115 Sled Backplane Back Connectors116 6shows the 12-sled backplane front connectors117 Power Distribution Board Connectors118 PDB Power and SMBus Connectors119 Contacting Dell120 121 Index122 123 124