Menu Fields

Settings

Comments

 

 

 

Serial Port Number

COM1

Serial port number

 

COM2 as SOL*

 

 

 

 

Serial Port Address

3F8h/2F8h*

COM1/COM2 IO port

 

2F8h/3F8h

address

 

 

 

 

 

Flow Control

None*

Flow control can prevent

 

Hardware

data loss from buffer

 

overflow. When sending

 

 

 

 

data, if the receiving

 

 

buffers are full, a 'stop'

 

 

signal can be sent to stop

 

 

the data flow. Once the

 

 

buffers are empty, a 'start'

 

 

signal can be sent to re-

 

 

start the flow. Hardware

 

 

flow control uses two wires

 

 

to send start/stop signals.

 

 

 

Redirection After BIOS

Disabled

Redirection After BIOS

POST

Always*

POST

 

 

 

 

 

Terminal Type

ANSI*

Emulation: ANSI:

 

VT100

Extended ASCII char set.

 

VT100: ASCII char set.

 

VT-UTF8

 

VT-UTF8: Uses UTF8

 

 

 

 

encoding to map Unicode

 

 

chars onto 1 or more bytes.

 

 

 

VT-UTF8 Combo Key

Disabled

Enable VT-UTF8

Support

Enabled*

combination key support

 

for ANSI/VT100 terminals.

 

 

NOTE: BIOS setup screens display at 100 (columns) x 31 (lines). Change the client-side console utility settings to support 100 (columns) x 31 (lines) for accurate screen display.

Using the System Setup Program

47

Image 47
Contents Dell PowerEdge C5220 Systems Regulatory Model B04S Important Information Page Contents 119 111About Your System Features Front-Panel Features and IndicatorsFeature Description Feature Status Description IndicatorsFeature Status Description About Your System About Your System About Your System About Your System About Your System Start Menu Using the System Setup ProgramConsole Redirection Bios Setup Options at BootEnable/Disable Console Redirection Key Ansi Escape Sequence Other Sequences Configuring Special KeysGeneral Help Conventions Server Platform Setup Utility ScreensMain Main MenuDisplays the processor type Advanced Advanced MenuPower Management State CPU ConfigurationAdvanced\CPU Configuration All DisabledEnabled Prefetch Configuration Enable Advanced\CPU Configuration\Prefetch ConfigurationAuto Memory ConfigurationAdvanced\Memory Configuration DisableAdvanced\SATA Configuration Sata ConfigurationDrive Port Mapping of Cougar Point Sata Controllers Onboard PCI ConfigurationAdvanced\PCI Configuration Gen2 Embedded Network Devices Advanced\PCI Configuration\Embedded Network DevicesEnabled with PXE Enabled without PXE Active State Power Management ConfigurationL0s & L1 Advanced\PCI Configuration\PCI Slot Configuration PCI Slot ConfigurationAdvanced\USB Configuration USB ConfigurationUSB Port with BMC Disabled Server Management Server ManagementMenu Fields Settings Comments Server Management/BMC Network Configuration Set BMC LAN ConfigurationIP Address Xxx.xxx.xxx.xxx Enter IP address Form Server/Remote Access Configuration Remote Access ConfigurationPost View System Event Log Using the System Setup Program Boot Boot MenuBios Security Security MenuSave & Exit Save and ExitCD/DVD ROM Status Codes Post Error HandlingError Messages Status Codes Status Code Description Command Line Interfaces for Setup options Recommended Tools Safety MeasuresInside the System Inside the SystemPowerEdge C5220 8-Sled SKU Sled ConfigurationRemoving a Sled SledsInstalling a Sled Dimm Population Rules Supported Dimm ConfigurationMemory Modules Supported Memory Supported MemoryDDR3 ECC VLP Removing a Memory Module Removing and Installing a Memory ModuleReplacing a Memory Module Removing a 2.5-inch Hard Drive Hard DrivesHDD2 HDD3 Installing a 2.5-inch Hard Drive Removing a 3.5-inch Hard Drive Remove the hard drive cables from the cable clips Installing a 3.5-inch Hard Drive Insert the hard drive cables into the cable clips Removing a 2.5-inch Hard Drive Board Hard Drive BoardsRemoving a 3.5-inch Hard Drive Board Installing a 2.5-inch Hard Drive BoardInstalling a 3.5-inch Hard Drive Board Removing a Heat Sink/Shroud Heat SinksRemoving a heat sink/shroud Installing a heat sink/shroud Installing a Heat Sink/ShroudFinal installed view of a heat sink/shroud Removing a heat sink Removing a Heat Sink10. Installing a heat sink Installing a Heat SinkRemoving a Processor ProcessorsInstalling a Processor Replacing a Mezzanine Card Optional Installing a 1 GbE and 10 GbE Mezzanine CardMezzanine Cards 11. Installing a Linking Board in a Mezzanine Card Removing a 1 GbE and 10 GbE Mezzanine Card 13. Securing a Mezzanine AssemblyRemove the card from the assembly 16. Inserting a Linking Board in a SAS Mezzanine Card Installing a SAS Mezzanine Card with 2.5 HDD17. Installing a SAS Mezzanine Assembly in a Sled Removing a SAS Mezzanine Card with 2.5 HDD Routing the 2.5 SAS Mezzanine Cables19. Removing a SAS Mezzanine Assembly in a Sled 20. Removing a SAS Mezzanine Card Installing a SAS Mezzanine Card with 3.5 HDD21. Inserting a Linking Board on a 3.5 SAS Mezzanine Card SAS Cable Identification Routing the 3.5 SAS Mezzanine CablesRemoving a SAS Mezzanine Card with 3.5 HDD 24 .5 SAS Cable SAS CableSystem Does Not Boot After Initial Installation Troubleshooting SequenceServer Boot Issues Product Family 100101 102 System Does Not Boot After Configuration Changes103 Installation ProblemsFirmware Recovery Utility-SOCFLASH Utility Update UtilitiesTroubleshooting External Connections BMC Firmware Update105 106 Updates Through TFTP/HTTP/FTP107 108 Bios Recovery Flow Bios System UpdateBios Recovery Mode Firmware Update Utility-AMI Flash Utility110 111 System Board Jumpers and ConnectorsJP5 112113 Inch Hard Drive Board Connectors114 Backplane ConnectorsSled Backplane Front Connectors 115 Sled Backplane Back Connectors116 6shows the 12-sled backplane front connectors117 Power Distribution Board Connectors118 PDB Power and SMBus Connectors119 Contacting Dell120 121 Index122 123 124