Dell MD3000 owner manual Installing the Control Panel

Page 65

Figure 4-7. Removing and Replacing the Control Panel

2

1

3

1 faceplate screws (16)

2

control panel

3

thumbscrews

6Using a Torx T10 driver, remove all 16 screws from the front faceplate of the enclosure as shown in Figure 4-7.

7Remove the front faceplate from the enclosure and place it on a flat, secure surface.

8Slide the control panel assembly straight out from its connector on the backplane (see Figure 4-7).

Installing the Control Panel

1Align the top and bottom tabs on the control panel with the insert slots on the edge of the chassis (see Figure 4-7).

2Slide the control panel fully into the slot, making sure that its connector engages into the matching backplane connector (see Figure 4-7). Also, make sure the guide tab on the control panel is fully inserted into the mounting slot on the backplane.

3Replace the front faceplate and re-attach the 16 screws that hold it in place.

4Re-install any physical disks you removed (see "Removing and Installing Physical Disks" on page 56).

5Push the enclosure all the way back into the rack and tighten the thumbscrews.

Installing Enclosure Components

65

Image 65
Contents W . d e l l . c o m s u p p o r t . d e l l . c o m Dell PowerVault MD3000 RAID EnclosureFebruary Contents Virtual Disk Migration and Disk Roaming Using Snapshot and Disk Copy TogetherWhen a RAID Controller Module Is Replaced or Removed Safety First-For You and Your Enclosure Returning Items for Warranty Repair or Credit Troubleshooting Enclosure Cooling Problems103 111About Your System Enclosure FeaturesOverview Modular Disk Storage Manager Other Information You May NeedIndicators on the Enclosure Bezel Hardware FeaturesPower green Front-Panel Indicators and FeaturesShould always be unlit EnclosureSplit mode LED green Enclosure mode switchPower LED green Steady green Back-Panel Indicators and Features RAID Controller Modules Green All links in port connected Off Battery backup unit and battery is operatingEach SAS port Off All links in port disconnected or cableRAID Controller Module Battery backup unit BBU tray Battery Backup Unit Cache Functions and FeaturesCooling fans On/off switch Power Supply and Cooling Fan FeaturesAC power LED Page About Your System About the Enclosure Connections Before You BeginRail kit Any relevant documentation, including Cabling Your RAID EnclosureRedundancy vs. Nonredundancy Single SAS In-Port ConfigurationsCabling the Enclosure MD1000 Expansion Enclosure Cabling Your RAID Enclosure MD1000 Expansion Enclosure Single-HBA host serverMD3000 RAID Enclosure Dual SAS In-Port Configurations MD1000 Expansion Enclosure RAID controller module Single-HBA host serverPage Page Page Attaching MD1000 Expansion Enclosures Expanding with Previously Configured MD1000 EnclosuresExpanding with New MD1000 Enclosures Cabling Your RAID Enclosure Physical Disks Using Your RAID EnclosurePhysical Disks, Virtual Disks, and Disk Groups Self-Monitoring Analysis and Reporting Technology Smart Physical Disk StatesVirtual Disks and Disk Groups Supported RAID LevelsDisk failures may result in data loss OfflineRAID Segment Size Hot Spares and RebuildRAID Level Usage Global Hot Spares Media Errors and Unreadable SectorsHot Spare Operation RebuildVirtual Disk Operations RAID Operations and FeaturesBackground Initialization Foreground InitializationCycle Time Disk Group OperationsRAID Level Migration Page Virtual Disk Migration and Disk Roaming RAID Background Operations PriorityUsing Your RAID Enclosure Storage Partitions Advanced FeaturesHost Types Snapshot Repository Virtual Disk Virtual Disk ServiceSnapshot Virtual Disks Virtual Disk Copy Volume Shadow-Copy ServiceUsing Snapshot and Disk Copy Together Multi-Path Software Hardware Redundancy and FailoverRedundancy and Non-Redundancy Host Cabling for Redundancy Host Bus AdaptersUsing Your RAID Enclosure When a RAID Controller Module Is Replaced or Removed RAID Controller Failover Modes RAID Enclosure Thermal ShutdownRAID Controller Module Firmware Updating Enclosure FirmwarePhysical Disk Firmware Expansion Enclosure FirmwareRemoving and Replacing the Front Bezel Installing Enclosure ComponentsRecommended Tools Removing Physical Disks from the Enclosure Removing and Installing Physical DisksInstalling SAS Physical Disks in the Enclosure Physical disk Removing a RAID Controller Module Removing and Installing a RAID Controller ModuleRemoving and Installing a RAID Controller Module Release tab Installing a RAID Controller ModuleBattery unit Removing a Power Supply/Cooling Fan Module Removing and Installing the Power Supply/Cooling Fan ModuleInstalling a Power Supply/Cooling Fan Module Removing the Control Panel Removing and Installing the Control PanelInstalling the Control Panel Removing and Installing the Midplane Controller/power supply cage Removing and Replacing the Controller/Power Supply CagePage Troubleshooting External Connections Safety First-For You and Your EnclosureTroubleshooting Your Enclosure Start-Up RoutineTroubleshooting a Damaged Enclosure Troubleshooting a Wet EnclosureProblem Liquid spilled on the enclosure Excessive humidityTroubleshooting Power Supplies Troubleshooting a Fan Troubleshooting Enclosure Cooling ProblemsTroubleshooting SAS Physical Disks Multiple physical disks are not seen in MD Storage Manager Single physical disk is not seen in MD Storage ManagerPhysical disk status LED is flashing amber ECC Errors Troubleshooting Enclosure ConnectionsPCI Errors Hard Controller Failures and Lockdown ConditionsNoncritical Conditions Critical ConditionsTroubleshooting Your Enclosure Getting Help Online ServicesObtaining Assistance Automated Order-Status Service AutoTech ServiceSupport Service Dell Enterprise Training Problems With Your OrderContacting Dell Before You CallTechnical Support Services Technical Support Dell Dimension, DellTechnical Support SalesInternational Access Code Tech Support for XPS SwitchboardCity Code Home/Small Business Fax Home/Small Business Customer CareCustomer Service small/med./large business Support Customer Service Home/Home OfficeHardware Warranty Phone Support Home/Home Office Hardware Warranty Phone SupportTechnical Support projectors, PDAs, switches Technical Support Dimension and InspironTechnical Support OptiPlex, Latitude, and Dell Precision Technical Support servers and storageSwitchboard Relational International Access Code Technical Support for XPSSwitchboard Fax Relational Switchboard Home/Small BusinessMail fisupport@dell.com Country Code Technical Support General Support calling from GuayaquilCity Code Customer Care Sales under 500 employeesCountry Code Technical Support for XPS Switchboard calls from outside of FranceCity Codes 1 Technical Support for all other Dell computers Fax calls from outside of FranceCountry Code Gold Service Technical Support International Access Code Technical SupportGold Service Switchboard Routers, and so on Customer CareStorage Sales Large Corporate Accounts Technical Support portables, desktops, servers,Sales Home and Small Business City Code Ireland SalesCountry Code Technical Support Inspiron Technical Support Dell Precision, OptiPlex, Technical Support outside of Japan DimensionLatitude Technical Support outside of Japan Dell Precision Routers Technical Support outside of Japan projectorsAccessories Sales City Code Support Dimension, PDA, Electronics,Customer Service Austin, Texas, U.S.A Fax Technical Support and Customer ServiceCity Code Latitude Technical Support Dimension, Inspiron, International Access Code Technical Support XPSCustomer Service Country Code Technical Support Dell Precision, OptiPlex,Fax Switchboard Switchboard FaxRelational Customer Care Relational SalesCountry Code Customer Care Customer Service FaxReception Desk Fax Switchboard Sales Precision Technical Support PowerApp, PowerEdgeInternational Access Code Mail dellzasupport@dell.com Technical Support, Customer Service, and SalesEmployee Purchase Program EPP Support City Code Relational Customer CareCity Code Technical Support Home and Small Business for All other Dell products Technical Support CorporateTechnical Support OptiPlex, Latitude, Inspiron PowerConnect, and PowerVault Customer CareMail delldirectsupport@dell.com Customer Care website International Access Code Country Code City CodeHome and Small Business Sales Corporate/Public Sector Sales100 101 102 Celsius Amperes AC Alternating currentBTU British thermal unit Cm Centimeters Cmos Complementary metal-oxide semiconductor 104Fahrenheit 105LVD Low voltage differential Meters MA Milliamperes 106107 TCP/IP Transmission Control Protocol/Internet Protocol System diskette See bootable diskette108 Volts VAC Volts alternating current VDC Volts direct current 109110 Index Safety Segment size migrationRedundancy consistency check Index
Related manuals
Manual 4 pages 50.55 Kb