Baldor Device Net Expansion Board, EXB013A01 manual Transaction Specification Table, Udint

Page 39

 

Table 6-1

Transaction Specification Table Continued

T#

Name

 

Type

Data Field

Class

Description

 

 

 

 

 

 

 

38

RunTime

 

Get

UDINT

E,V,S

Total time power has

 

 

 

 

 

 

been applied. Units:

 

 

 

 

 

 

seconds.

 

 

 

 

 

 

 

39

TableSelect

 

Get/

USINT

E,S,V

Parameter table

 

 

 

Set

 

 

select

 

 

 

 

 

 

Range 0 – 3

 

 

 

 

 

 

Note: DDC only

 

 

 

 

 

 

supports 2 tables.

 

 

 

 

 

 

Can only be

 

 

 

 

 

 

changed when under

 

 

 

 

 

 

network control

 

 

 

 

 

 

 

40

AccDecGroup

 

Get/

USINT

E,V,S

Accel / decel group

 

 

 

Set

 

 

select

 

 

 

 

 

 

Range 1 – 2 Can

 

 

 

 

 

 

only be changed

 

 

 

 

 

 

when under network

 

 

 

 

 

 

control.

 

 

 

 

 

 

 

41

WatchdogTime

 

Get/

UINT

All

Network watchdog

 

 

 

Set

 

 

timer Get Units:

 

 

 

 

 

 

10mS

 

 

 

 

 

 

0 = disable

 

 

 

 

 

 

2= 20mS minimum

 

 

 

 

 

 

6000= 60S

 

 

 

 

 

 

maximum

 

 

 

 

 

 

Note: resolution

 

 

 

 

 

 

varies among

 

 

 

 

 

 

product classes.

 

 

 

 

 

 

 

45

FaultStatus

 

Get

USINT

All

Request current fault

 

 

 

 

 

 

condition

 

 

 

 

 

 

0 = No fault

 

 

 

 

 

 

1–xx = Current fault

 

 

 

 

 

 

code (See H Series

 

 

 

 

 

 

– Fault Message

 

 

 

 

 

 

Description table at

 

 

 

 

 

 

the end of this

 

 

 

 

 

 

section for

 

 

 

 

 

 

description.)

 

 

 

 

 

 

 

* Indicates initial powerup value.

6-10 Command Language

Image 39
Contents MN1320 Installation and Operating ManualTable of Contents Ii Table of Contents Introduction Section General InformationLimited Warranty Safety Notice General Information Section Expansion Board Description Description Board Installation Section InstallationAC Controls Single Expansion Board InstallationSingle Expansion Board Installation AC Controls Single Expansion Board InstallationDual Expansion Board Installation Dual Expansion Board Installation Installation Cable Connection Hardware SetupDIP Switch Settings Powerup3 4 5 6 7 Board ConfigurationSwitch Settings LED Indicators LED State Status DescriptionOFF Serial Opto Input Connections Control Terminal Strip ConnectionsHardware Setup Configure Control Software for Device Net Mode Software SetupAction Description Display Comments Local EnterEXB I/O Instances Device Net ConfigurationFormat of Input Assembly Instances Rev Fwd 153 CtrlSourceT#3 RunCMDT#1 FreqActual T#19 Low Byte Format of Output Assembly Instances Page Transaction Number T# Command LanguageTransaction Specification How To Read The Transaction SpecificationType NameData Field Description ClassBool Transaction Specification TableName Type Data Field UsintName Type Data Field Class Description 1Transaction Specification TableDint INTCurrentActual Get Word StringUint Udint FaultRst Set None BlockParamDetail Get ParameterValue Set Byte Transaction Specification Table Command Mode INC 2Command Mode TableValue Mode Class Description ABSTerminalStrip 3TerminalStrip TableBit Name Typical Single-Axis Typical Multi-Axis Location 36 or 37 Optionald# 4Optionald# TableEXB No EXB Name Group Scale/ Units 10mS ParameterDetails WatchdogTimeField Name Description 5ParameterDetails TableFLT Fault Code Fault Description 15H 18HSens  Baldor Electric Company MN1320 03 C&J500

Device Net Expansion Board, EXB013A01 specifications

The Baldor EXB013A01 Device Net Expansion Board is a cutting-edge component designed to enhance the functionality of Baldor's motion control products. Offering a robust solution for integrating control systems within industrial automation, this expansion board allows for seamless communication between various devices over a DeviceNet network.

One of the main features of the EXB013A01 is its ability to deliver precise control capabilities. It enables users to connect additional I/O devices, sensors, and actuators, which is crucial for complex automation tasks. This flexibility ensures that users can customize their systems according to specific operational needs while maintaining a high degree of efficiency.

The integration of DeviceNet technology is a key characteristic of the EXB013A01. DeviceNet is a widely recognized network protocol based on the Controller Area Network (CAN) and is designed to facilitate communication between various devices in a manufacturing environment. With its ability to support multiple master and slave devices, the EXB013A01 ensures that information is exchanged swiftly and reliably, which is critical for real-time processing and decision-making in automated environments.

Another significant feature of this expansion board is its ease of installation and configuration. Equipped with a user-friendly interface, the EXB013A01 allows operators to quickly set up connections and configure network parameters. This streamlined process reduces downtime during installation and improves overall productivity on the manufacturing floor.

The EXB013A01 also boasts high reliability and durability. Built to withstand harsh industrial environments, it is designed with sturdy components that ensure long-term performance. This reliability is paramount as it minimizes the risks of Service interruptions, safeguarding critical manufacturing operations.

In summary, the Baldor EXB013A01 Device Net Expansion Board stands out as a vital addition to Baldor's motion control lineup. With its precise control capabilities, robust DeviceNet integration, user-friendly setup, and high durability, it serves as an essential tool for manufacturers aiming to enhance their automation systems and drive operational excellence. Integrating this expansion board into existing setups can greatly improve flexibility and efficiency, making it an invaluable asset for any modern industrial automation application.