Appendix A – Web Xpander Commands

Command

Description

Example

:reset=

Resets the Web Xpander

:reset=

:factory=

Load factory default

:factory=

 

values (follow with

 

 

:reset= to restart

(then optionally) :reset=

 

with these values)

 

:ipaddr=

Sets the IP Address

:ipaddr=192.168.0.20

:ipmask=

Sets the Netmask

:ipmask=255.255.255.0

:ipgate=

Sets the Gateway Addr.

:ipgate=192.168.0.1

:dns=

Sets the DNS Address

:dns=192.168.0.1

:dhcp=

Enabled/Disables DHCP

:dhcp=1

:smtp=

Sets the outgoing

:smtp=smtp.comcast.net

 

(SMTP) mail server

 

:user=

Sets the user name

:user=myname

 

required for access

 

:pass=

Sets the password

:pass=mypass

 

required for access

 

:webport=

Sets the port (default =

:webport=80

 

80) for the web server

 

:telnet=

Sets the port (default =

:telnet=23

 

23) for

 

 

telnet (Ethernet to

 

 

Serial)

 

:time=

Sets the internet Time

:time=time-b.nist.gov

 

server for time

 

 

synchronization

 

:daily=

Sets the daily time sync

:daily=210

 

in number of minutes

(i.e. 3:30am)

 

from midnight

 

:netinfo=

Displays network

:netinfo=

 

settings

 

:mailto=

Sets a email recipient –

:mailto=myemail@yahoo.com

 

Can be sent up to 5

:mailto=someone@hotmail.com

 

times per message to

 

 

indicate up to 5

 

 

recipients

 

:mailfrom=

Sets the email sender

:mailfrom=myhouse@home.com

:mailsubject=

Sets the email subject

:mailsubject=Test Email

:mailbody=

Sets one or more lines of

:mailbody=Motion Sensor 1

 

email text.

Activated

 

This command can be

 

 

sent multiple times up to

 

 

500 characters total.

 

:mailsend=

Sends the email

:mailsend=

Image 15
Contents Web Xpander Web Xpander What You Need Installing the Web XpanderWelcome to Web Xpander What’s IncludedNetwork Connection Network Configuration Viewing Current Network Settings Command Description Example Manually Configuring Web Xpander Network SettingsLighting Web PagesX10 Digital Analog Relay Timer Ascii MSG LOG TEL LOG Auto Page Refresh SettingsImporting and Sending Device Labels ConfigurationLoad Default Labels Web Xpander LabelerAppendix a Web Xpander Commands Description Example Enables or disables Appendix B Sending Email with the Web Xpander Smtp AuthenticationAppendix C Managing a Dynamic Home Internet Address Appendix D Ethernet to Serial Bridge Functionality Page Page Appendix F Performing a Firmware Update on the Web Xpander Page Page Page Advanced Appendix H Internet Time Synchronization Appendix I Advanced WebXpander URL Commands Example Event Disable Webx Appendix K Web Xpander Firmware Release History Page Page