Example 1: sendcommand.cgi?var1=%23%23%2507&var2=str&var3=%23%230
%23 is the
Example 1 (above) sends the command ##%07 and waits for the string ##0
Example 2: sendcommand.cgi?var1=%23%23%2520&var2=time&var3=1500
Example 2 sends the command ##%20 (x10 status) and waits 1.5 seconds (1500 ms) for the command to complete.
•Fixed Internet Time Sync Daylight Savings problem v1.3
•Added option to disable time sync on WebX Settings page (as default)
•Added additional checking in internet time sync to ensure time is set correctly
•Added additional web page for custom application interaction sendcommand2.cgi : Sends command to STARGATE and returns results
This page is not protected through browser security (i.e. username/password popup) but requires the username/password be passed on the URL to make it easier to use from other systems (i.e. custom interfaces) that may have trouble with browser authentication
sendcommand2.cgi?var1=<command>&var2=<stop condition>&var3=<stop param>&var4=username&var5=password
Examples:
sendcommand2.cgi?var1=%23%23%2507&var2=str&var3=%23%230&var4= webx&var5=webx (send ##%20, wait for string ##0)
sendcommand2.cgi?var1=%23%23%2507&var2=time&var3=1500&var4= webx&var5=webx (send ##%07, wait for 1.5 sec)
•A/V Page doesn't disappear and refresh after each command is sent
•Widths of text areas in Message Log, Telephone Log, and History pages were made wider
v1.3b
•Bug in determining PreSet Dim and Extended Code commands fixed