NOTES:

If an error message and incorrect audio response occur, diagnose the error message first.

If you cannot run the diagnostics program tests but did receive a POST error code, diagnose the POST error message.

If you did not receive any error message, look for a description of your error symptoms in “Error Symptoms List” in page79.

Check all power supply voltages, switch, and jumper settings before you replace the system board. Also check the power supply voltages if you have a “system no-power” condition.

(“Power Supply Cable Connector Specifications” on page 129

If the problem cannot be corrected by using the “BIOS Error Codes, Messages, And Beeps List” table and “Error Symptoms List” table, go to "Undetermined Problems” on page 104.

Table 2-1 BIOS Error Codes, Messages, and Beeps List

BIOS Error Codes, Messages, beeps

Action/FRU

NOTE: To diagnose a problem, first find the BIOS error messages, codes, or beeps in left column. If directed to a check procedure, replace the FRU indicated in the check procedure. If no check procedure is indicated, the first Action/FRU listed in right column is the most likely cause.

POST Error Codes and Messages

 

Load default settings in Setup and

CMOS battery failed

reboot the system.

 

 

CMOS battery.

 

System board.

 

 

 

Make sure the equipment (diskette

CMOS checksum

drive, hard disk drive, keyboard,

mouse, etc.) are connected properly

error

and are set correctly in BIOS Setup.

 

 

Load default settings in setup.

 

CMOS battery should be replaced.

 

System board.

 

 

 

Make sure the DIMMs are inserted

Memory size error

properly.

 

 

System board.

 

 

75

Page 77
Image 77