If a newly replaced FRU does not correct the problem: If you have reached this point of the check procedures and were instructed to replace a FRU but doing so did not correct the problem, reinstall the original FRU and go through "Start" again.
If you want to print a copy of a BIOS Setup Utility screen to an attached printer, press Print Screen key, while the screen is displayed.
PLEASE READ THE FOLLOWING:
Human Error is a cause for concern when applied to check procedures. It exists in every first time set of analysis procedures. It is therefore essential for effective and
001 - START
To begin, note the following:
qDisable the setting of “Quick
qDisconnect all external cables and devices including speakers and microphone from the system unit, except for the keyboard, mouse, and monitor.
qPower off the system unit before moving it or when replacing FRUs.
qRemove all adapter cards, except for the
qDisconnect any drives except:
q
q Hard disk drive
q
qMake sure that all power cords and cables are connected properly.
qMake sure that the monitor brightness and contrast controls are not turned down.
qPower on the system unit.
NOTE: Some monitors have a detachable system I/O signal cable between the monitor and the system unit. In this case, check this signal cable before replacing the unit. See “Monitor Port Signals” on page 136 for pin identification.