Appendix F – Performing a Firmware Update on the Web Xpander
**Note: This applies only to firmware versions prior to v1.6 July 16, 2003 (See Appendix G for updating firmware versions 1.6 and later)
The firmware is the software that runs embedded within the Web Xpander. Periodically, a new version of the firmware may be made available either to address issues found in a prior version or to provide new features and functionality.
To perform a firmware update on the Web Xpander, the following items are required:
•Rabbit Programming Ribbon Cable – Available from Rabbit Semiconductor. See the JDS Technologies web site (on the Web Xpander Download page) for more information.
•Rabbit Firmware Utility (RFU) – Available on the Web Xpander CDROM and the JDS Technologies web site (on the Web Xpander Download page).
•Latest Web Xpander Firmware – Available on the JDS Technologies web site (on the Web Xpander Download page).
•Latest Web Xpander Labeler - Available on the JDS Technologies web site (on the Web Xpander Download page).
In preparation for the firmware update, make sure you have successfully installed both the Firmware Utility and the latest version of the Web Xpander Labeler application. Both of these applications will appear on your Start menu in the Web Xpander folder.
The Web Xpander firmware is transferred via the Rabbit Programming ribbon cable. One end of this cable has a
*** IMPORTANT ***
It is very important to properly connect this cable to the Web Xpander. One side of the cable is marked with a red stripe. This stripe indicates Pin 1 and must align with the correct pin on the Rabbit