Napco Security Technologies GEM-DXRP2 Select the Program Mode as follows, Programming Example

Page 27

PROGRAMMING (OPTIONAL)

Programming Example:

Program the User 3 Code to “3784”:

1.Select the Program Mode as follows:

(a)Enter your User Code, followed by A.

(b)Answer NO (press F) repeatedly until “TurnOn Prog Yes/No” is displayed, then press YES (E).

The display will briefly read: “UPXXXX” then "User01" (User 1's Code).

2.Press 03for User No. 3.

3.Press Ato advance to the User Code screen.

4.Press 3784to program the code. If any other digits are left over from a previous User-3 Code, delete each by pressing G0.

Note: Do not attempt to program the "OPTion" or "ACCess" screens (if they display) as they will not be saved.

5.Press J to save the code.

6.Press Cto exit the Program Mode.

Notes:

Note: Duplicate Codes are not allowed; therefore a dupli-

cate Code entered in the LCD Window will erase when Dis pressed.

If the system contains more than one keypad, only the keypad designated “No. 1” may be used for programming (if in doubt which is No. 1, ask your installer).

While in Program Mode, the ARMED and STATUS lights remain off and burglar and fire alarm functions are disabled.

In selecting your codes, do not program repetitive numbers (1111), consecutive numbers (1234), your birth date, address, or other obvious combinations. Choose a code of up to six digits (a minimum of four is recommended, and required in UL installations). If the keypad detects no Program Mode activity for more than 4 minutes, a tone will sound. Press Cto silence.

27

Image 27
Contents AC on Ready Operating Guide for yourIntroduction Important Test Your System WeeklyTest your sounding device Test your telephone line Table of Contents Keypad Controls & Indicators Reset InstantON/OFF Setting the Alarm Arming When Leaving Cant ArmSilCANT/ ArmRst CANT/ARM TrblEXX-XX READY1Armed Protecting Yourself While on the PremisesBypassing Interior Zones INT1+2Armed Instant Protection Turning OFF the AL ARM Disarming When Returning DisarmXxxsec Hour Zone 24-Hour Zones programmed? ‰YES ‰NO Day Zone Day Zones programmed? ‰YES ‰NOFire Protection Fire ZonexxTRBL/ E41-XX Important! Read Carefully Would You Like More Safety Information?Preparing a Fire Escape Plan Family RehearsalFloorplan FloorplanLimitations of Fire Alarm Warning System Keypad Functions R Z R n O n / C h i me Y e s / N o L a y/ Ar m 1 4/ / N o On Zone 1 has not been received Central Station Monitoring Communicator FeaturesAdvanced Features ZONE02Bypass Page Programming Optional IntroductionProgramming User Codes User Programming Example Select the Program Mode as followsARMED1 Keypad MessagesWait ExitxxCancel ArmZnfArmSnd Wrong AlarmDAY ZN FireCommfl SystblAcfail LobattClosing Window Optional. a GlossaryGlossary Glossary System Trouble Error Codes Following Statement is Required by the FCC Napco Limited Warranty