Lowrance electronic LMF-400 manual Recalibrate option

Page 30

Used shown by the gauge. If the difference between these two figures is greater than 5 percent, then you need to recalibrate the unit.

3.To do this, after entering the tank has been refilled, select YES on the

RECALIBRATE option.

4.Then enter in the amount of fuel added to fill the tank. The calibration is calculated by comparing the actual fuel used to the calculated fuel used. It is vital to get an accurate reading on the actual fuel used and the amount of fuel added to fill the tank the second time. On multiple engine installations with a single tank configuration, only one engine should be run when calibrating the EP-10 Fuel Flow. This is the only way to know how much fuel has gone through the EP-10 Fuel Flow you want to calibrate.

Refill Tank

1.After you have filled the gas tank, scroll through the pages until the Fuel Manager page is on the main display. Press MENU.

2.Highlight FUEL SETUP and press ENTER.

3.Scroll down the menu to REFILL TANK and press ENTER, which will call up the following message: ReCalibrate? A menu will be below the message with two options: Yes or No.

4.Highlight YES and press ENTER, which will launch the Filled Fuel Quantity window.

5.Use the UP and DOWN keys to enter the number of gallons you put in the tank and press ENTER to finalize the calibration. You will be directed back to the Fuel Setup menu.

Partial Fill

1.Scroll through the pages until the Fuel Manager page is on the screen, then press MENU.

2.Highlight FUEL SETUP and press ENTER.

3.Scroll down to PARTIAL FILL and press ENTER, which will launch the Adding Fuel Window.

4.Use the UP and DOWN keys to enter the amount of fuel you added to the tank, then press ENTER. You will be directed back to the Fuel Setup menu.

Trim Tabs

If the Trim Tabs have not been calibrated or have been reset, the display will flash between 0 and 100. This is normal prior to the trim tabs being calibrated for the first time.

Trim Tabs can only be calibrated from the Trim Tabs page. If the page is not present in the scrolling page display, add the Trim Tab page by following the Adding Pages instructions in Section 3: Operation.

28

Image 30
Contents LMF-400 Copyright 2005 Lowrance Electronics, Inc All rights reserved Table of Contents To unconfigure Fluid Level Calibrate Introduction Page Preparation Mounting the UnitPage Nmea 2000 network node located at the end of a Nmea 2000 bus Page Boat Setup OperationPages Page Viewing options Basic MenuPage Page Screen Audio Setup Press Exitexit to return to the main displaySystem Setup Page EP Configuration Calibration Unconfigure or Reconfigure Page Fluid Level Enter To configure Waste Water Page Calibration of EP Devices Page Recalibrate option Page Page Customizing Pages Single AnalogDual Analog Quad AnalogSingle Digital Dual Digital Quad Digital Trim TabsGPS Position Fuel ManagerPage System Setup Menu Enter Page Change Units Enter Lowrance Electronics Full ONE-YEAR Warranty How to Obtain Service… Accessory Ordering Information for all countries Visit our web site