Lowrance electronic LMF-400 manual

Page 23

In the following example, we want to swap the configuration of Temp 2 and Temp 1. We will first unconfigure Temp 2, then reconfigure Temp 1 as Temp 2. We'll finish by configuring UnCfg Temp (formerly Temp 2) as Temp 1.

1.Highlight TEMP 2 on the Bus Devices list and press ENTER, which will launch the temp sensor configuration menu.

2.Choose UNCONFIGURE and press ENTER. The following message will pop up: Hit Menu to UnCfg Temp Sns.

3.Press ENTER, and you will be taken back to the Bus Devices list.

4.Select TEMP 1 from the Bus devices menu and press ENTER. Choose RECONFIGURE and press ENTER. That will direct you to the Temp Selection menu.

5.Select TEMP 2 and press ENTER, which will take you back to the Bus Devices list.

6.Now highlight UNCFG TEMP from the Bus Devices list and press ENTER, which will call up the Selecting Temp menu. Choose one of the Temp options (Temp 1, Temp 3, etc.) and press ENTER. You will be returned to the Bus Devices list.

NOTE:

To run a system check for devices connected to the NMEA 2000 network, select BUS DEVICES from the System Setup menu and press ENTER. A Searching Bus Devices message comes up, followed by a list of all devices attached to the LowranceNET — the Bus Devices list. To select an item from the bus devices list, use the UP and DOWN keys to scroll through the list. Highlight the desired category and press ENTER.

Fuel Flow (Port, Center and Stbd)

Port Fuel Flow (Port Fflow), Center Fuel Flow (Cen Fflow) and Starboard Fuel Flow (Stbd Fflow) all share the same internal configuration menu, which includes: Change Engine (for two or more engines only), Fuel Warning, Unset Engine and Reset Values. After selecting a Fuel Flow (Port, Center or Stbd) from the Bus Device list and pressing ENTER, the following options will appear in the menu.

To Unconfigure Fuel Flow:

See Unset Engine below.

To Configure Fuel Flow:

1.From the Bus Devices list, highlight UNCFG F FLOW and press ENTER. That will launch the following message: Hit Menu to Cfg Flow Sns.

2.Press ENTER to proceed with configuration.

21

Image 23
Contents LMF-400 Copyright 2005 Lowrance Electronics, Inc All rights reserved Table of Contents To unconfigure Fluid Level Calibrate Introduction Page Mounting the Unit PreparationPage Nmea 2000 network node located at the end of a Nmea 2000 bus Page Operation Boat SetupPages Page Basic Menu Viewing optionsPage Page Screen Press Exitexit to return to the main display Audio SetupSystem Setup Page EP Configuration Calibration Unconfigure or Reconfigure Page Fluid Level Enter To configure Waste Water Page Calibration of EP Devices Page Recalibrate option Page Page Single Analog Customizing PagesQuad Analog Dual AnalogSingle Digital Dual Digital Trim Tabs Quad DigitalFuel Manager GPS PositionPage System Setup Menu Enter Page Change Units Enter Lowrance Electronics Full ONE-YEAR Warranty How to Obtain Service… Accessory Ordering Information for all countries Visit our web site