Lynx Series 5000 Rack Frame, R FR 5011, R FR 5010 manual Extend Connection

Page 19

Reference Manual R FR 5010 Version1.4

Extend Connection

Bus Extension. This connection is used to interface racks together when using the optional LYNX control system. This is a simple (and inexpensive) way to extend the reach of the host RCT 5020 controller into several more racks fitted with RCT 5010 bus expanders. It uses a proprietary LYNX control interface and this connection is physically daisy chained between all connected racks. Connection details can be seen in the table below.

The connection is a 9 pin SubD female connector. Function and connection information is described below.

Connector wiring detail when used for the Bus Extension

Pin

 

Connection

 

Pin

 

Connection

 

Number

 

 

Number

 

 

 

 

 

 

 

 

1

 

Prop CLK A

6

 

Prop CLK B

2

 

Prop TX A

7

 

Prop TX B

3

 

Prop RX B

8

Prop RX A

4

 

GND

9

 

Prop SEL 2

5

 

Prop SEL 1

 

 

 

 

Note the “prop” term refers to proprietary for the LYNX interface.

5 1

6 9

Figure 7. Extend Connector

Note. When using this interface all connected racks must be mounted close together, (preferably with no space in-between racks), as the distance of this interface is restricted. Please refer to the R CT 5010 Rack Bus Expander reference manual for more details on this interface and the cables required.

Page 19

Image 19
Contents Reference Manual Ver Reference Manual R FR 5010 Version1.4 Double Pole / Neutrale Fusing Warnung This Page is intentionally left blank Warranty Declaration of Conformity EuropeFCC 47 Part Contents Reference Manual R FR 5010 Version1.4 Packaging Getting StartedProduct Description Reference Manual R FR 5010 Version1.4 Exploded rack view Rack LayoutReference Manual R FR 5010 Version1.4 Power Supply Power Supply seen From Front Rear Termination Panel Power ConnectionRack Connections Alarm Connector Alarm ConnectionOver temperature Redundant Power Supply Failure Alarm FunctionExtend Connection Connector wiring detail when used for the Bus ExtensionControl Connection External Sync Connection LAN ConnectionLEDs and indicator locations and function Alarm/LED Status IndicatorsFan Alarm LED R FR 5011 only Power Supply LED IndicatorsRear Connection Plates Rack ConfigurationAssembly Rack Layout ConsiderationsRemote Controller Redundant Power SupplySelection shown is just an example Rackwith CardModules Power SuppliesPower Supply Failure Hot SwappingLocation Rack InstallationVentilation Front Panel Removal R FR Mechanical InstallationSub D 9 Connector on Front Cover of R FR Electrical Installation Installation Instructions Installations-Anweisung Settings and Control Specifications R FR 5010 / R FR Model Description Available OptionsService Parts ListWebsite Mail Contact InformationReference Manual R FR 5010 Version1.4