Reference Manual R FR 5010 Version1.4
Control Connection
An external Control Interface is provided on the rear termination panel. When an R CT 5020 Rack Controller (or R CT 5030 Master Controller) is fitted to the rack this port can be used for two primary functions:
1.When configured as a RS 232 serial port this can be connected directly to a PC running the LYNX control software.
2.When configured for RS 422 operation this port is used to daisy chain other racks fitted with R CT 5020 Rack controllers (up to 15 additional racks)
Note. Please refer to the R CT 5020 Reference Manual for details on how to
The connection is a 9 pin SubD female connector. Function and connection information is described below.
Connections for RS 422
Pin |
| Connection |
| Pin |
| Connection |
|
Number |
|
| Number |
|
| ||
|
|
|
|
|
| ||
1 | GND Shield | 6 | GND | ||||
2 | TX A 422 | 7 | TX B 422 | ||||
3 | RX B 422 | 8 | RX A 422 | ||||
4 | GND | 9 | GND Shield | ||||
5 | GND |
|
|
|
|
Connections for RS 232
Pin |
| Connection |
| Pin |
| Connection |
|
Number |
|
| Number |
|
| ||
|
|
|
|
|
| ||
1 | GND Shield | 6 | GND | ||||
2 | TX 232 | 7 |
|
|
| ||
3 | RX 232 | 8 |
|
|
| ||
4 | GND | 9 |
| GND Shield | |||
5 | GND |
|
|
|
|
Page 20