| Reference Manual R FR 5010 Version1.4 |
|
|
Specifications (R FR 5010 / R FR 5011) | |
Mechanical |
|
Size | 2 RU high x 32.5 cm deep including connectors |
| and front cover. 31 cm without front cover. |
| Standard 19” rack mount. |
Weight (empty) | R FR 5010: 4 kg with single power supply |
| R FR 5011: 4,25 kg with single power supply |
Connections | All connections made on rear of rack |
|
|
Performance |
|
Available Card Slots | 10 x CardModules |
| 1 x Controller |
| 2 x Power Supplies (primary and redundant) |
Power Indication (alarm) | One multifunction LED per supply and GPO output |
| Fan Alarm through front cover (R FR 5011 only) |
| Module alarm LEDs visible through front cover |
Controller alarm | LED bar |
| |
Connections (rear connections) | |
LAN Connector | RJ 48 |
Control | 9 Pin female SubD (RS 485) |
Extend | 9 pin female SubD (RS 232) |
Alarm Connector | 9 Pin male Sub D (GPO and GPI) |
Ref In | BNC connection for rack reference, with loop |
| output |
Primary AC | IEC power connector, fused (2A) |
Redundant AC | IEC Power connector, fused (2A) |
| |
Electrical Specifications | |
Power Input | 100 – 240VAC, 50Hz – 60Hz. Two separate and |
| isolated connections for Primary and Redundant |
| supplies. |
Power Consumption | 130W max. |
Safety | IEC 60950/ EN 60950/VDE 0805 |
|
|
Ambient |
|
Temperature | 5°C to 40°C Maintaining specifications |
| 0°C to +50°C Operating |
Humidity | Max 90% non condensing |
| |
Supplied Accessories | |
Documentation | R FR 5010 / R FR 5011 Reference Manual |
Page 35