Lynx R FR 5011, Series 5000 Rack Frame manual Specifications R FR 5010 / R FR

Page 35

 

Reference Manual R FR 5010 Version1.4

 

 

Specifications (R FR 5010 / R FR 5011)

Mechanical

 

Size

2 RU high x 32.5 cm deep including connectors

 

and front cover. 31 cm without front cover.

 

Standard 19” rack mount.

Weight (empty)

R FR 5010: 4 kg with single power supply

 

R FR 5011: 4,25 kg with single power supply

Connections

All connections made on rear of rack

 

 

Performance

 

Available Card Slots

10 x CardModules

 

1 x Controller

 

2 x Power Supplies (primary and redundant)

Power Indication (alarm)

One multifunction LED per supply and GPO output

 

Fan Alarm through front cover (R FR 5011 only)

 

Module alarm LEDs visible through front cover

Controller alarm

LED bar

 

Connections (rear connections)

LAN Connector

RJ 48

Control

9 Pin female SubD (RS 485)

Extend

9 pin female SubD (RS 232)

Alarm Connector

9 Pin male Sub D (GPO and GPI)

Ref In

BNC connection for rack reference, with loop

 

output

Primary AC

IEC power connector, fused (2A)

Redundant AC

IEC Power connector, fused (2A)

 

Electrical Specifications

Power Input

100 – 240VAC, 50Hz – 60Hz. Two separate and

 

isolated connections for Primary and Redundant

 

supplies.

Power Consumption

130W max.

Safety

IEC 60950/ EN 60950/VDE 0805

 

 

Ambient

 

Temperature

5°C to 40°C Maintaining specifications

 

0°C to +50°C Operating

Humidity

Max 90% non condensing

 

Supplied Accessories

Documentation

R FR 5010 / R FR 5011 Reference Manual

Page 35

Image 35
Contents Reference Manual Ver Reference Manual R FR 5010 Version1.4 Double Pole / Neutrale Fusing Warnung This Page is intentionally left blank Warranty FCC 47 Part EuropeDeclaration of Conformity Contents Reference Manual R FR 5010 Version1.4 Product Description Getting StartedPackaging Reference Manual R FR 5010 Version1.4 Exploded rack view Rack LayoutReference Manual R FR 5010 Version1.4 Power Supply Power Supply seen From Front Rack Connections Power ConnectionRear Termination Panel Alarm Connector Alarm ConnectionOver temperature Redundant Power Supply Failure Alarm FunctionExtend Connection Connector wiring detail when used for the Bus ExtensionControl Connection External Sync Connection LAN ConnectionLEDs and indicator locations and function Alarm/LED Status IndicatorsFan Alarm LED R FR 5011 only Power Supply LED IndicatorsRear Connection Plates Rack ConfigurationAssembly Rack Layout ConsiderationsRemote Controller Redundant Power SupplySelection shown is just an example Rackwith CardModules Power SuppliesPower Supply Failure Hot SwappingVentilation Rack InstallationLocation Front Panel Removal R FR Mechanical InstallationSub D 9 Connector on Front Cover of R FR Electrical Installation Installation Instructions Installations-Anweisung Settings and Control Specifications R FR 5010 / R FR Model Description Available OptionsService Parts ListWebsite Mail Contact InformationReference Manual R FR 5010 Version1.4