Hot Swapping

Power Supplies

The Series 5000 CardModules and Power Supplies are fully hot swappable in the event of a fault or failure.

Power Supply Failure

A failure in the Primary power supply will automatically trigger the use of the redundant supply (if fitted) and will trigger the following alarm conditions / indications(requires controller option).

Reported fault on the monitoring system

Alarm GPO trigger on the alarm connector (see Alarm Connections section)

Front Panel LED (normally green) will go out (See Alarm / Status indication section)

Once identified, the defective supply can be removed and replaced with power connected with no interruption to the operation of the CardModules.

CardModules

If a CardModule fails the error will be reported over the monitoring system and via the front side alarm LED. Alarm function is module dependant so please refer to the CardModule manual for failure conditions and indications. The defective CardModule can be removed and replaced with an identical replacement without removing power from the frame.

Page 27

Image 27
Contents Reference Manual Ver Reference Manual R FR 5010 Version1.4 Double Pole / Neutrale Fusing Warnung This Page is intentionally left blank Warranty Europe Declaration of ConformityFCC 47 Part Contents Reference Manual R FR 5010 Version1.4 Getting Started PackagingProduct Description Reference Manual R FR 5010 Version1.4 Exploded rack view Rack LayoutReference Manual R FR 5010 Version1.4 Power Supply Power Supply seen From Front Power Connection Rear Termination PanelRack Connections Alarm Connector Alarm ConnectionOver temperature Redundant Power Supply Failure Alarm FunctionExtend Connection Connector wiring detail when used for the Bus ExtensionControl Connection External Sync Connection LAN ConnectionLEDs and indicator locations and function Alarm/LED Status IndicatorsFan Alarm LED R FR 5011 only Power Supply LED IndicatorsRear Connection Plates Rack ConfigurationAssembly Rack Layout ConsiderationsRemote Controller Redundant Power SupplySelection shown is just an example Rackwith CardModules Power SuppliesPower Supply Failure Hot SwappingRack Installation LocationVentilation Front Panel Removal R FR Mechanical InstallationSub D 9 Connector on Front Cover of R FR Electrical Installation Installation Instructions Installations-Anweisung Settings and Control Specifications R FR 5010 / R FR Model Description Available OptionsService Parts ListWebsite Mail Contact InformationReference Manual R FR 5010 Version1.4