Opticon NFT 2100 manual Appendix B

Page 21

Manual No. 25-ULNFT2100-01; Mar, 2005

NFT 2100 CCD Fixed Mount Barcode

Scanner

 

Appendix B

Computer Programming Commands

All commands listed below must be preceded by an 'ESC' (x1B) or 'STX' (x02) character and be followed by a 'Carriage Return' (x0D) or 'ETX' (x03) character. Shaded areas indicate factory default settings.

Enable

 

Disable

Global Defaults

 

 

 

 

 

 

U2

 

 

 

Enable Factory Default Settings

Z1

 

 

 

Transmit software version

 

 

 

 

 

 

Z2

 

 

 

Save all values set by command

 

 

 

 

 

 

Z3

 

 

 

Display software setting flags,

 

 

 

prefix/suffix, & min/max lengths.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Only

Add

Symbology Selection

 

 

 

 

 

A0

 

 

Enable all symbologies

 

 

 

 

 

B0

 

 

Disable all symbologies

 

 

 

 

 

J0

 

 

Enable all UPC and EAN plus add-ons

 

 

 

A2

 

B2

Code 39

A3

 

B3

Codabar (NW-7)

A4

 

B4

IATA

A5

 

B5

Code 93

A6

 

B6

Code 128 (Inc. EAN-128)

A7

 

B7

MSI/Plessey

A1

B1

UK/Plessey

Enable Disable

E2

E3

E4

E5

E6

E7

E8

E9

6P

6Q

 

 

Options for UPC-A and UPC-E

UPC-A as EAN13 (13 Digits) Transmit leading zero & CD

UPC-A (12 Digits) No leading zero but transmit CD

UPC-A as EAN13 (12 Digits) Transmit leading zero but No CD

UPC-A (11 Digits) No leading zero & no CD transmitted

UPC-E (8 Digits)Transmit leading zero & CD

UPC-E (7 Digits) No leading zero but transmit CD

UPC-E (7 Digits) Transmit leading zero but no CD

UPC-E (6 Digits) No leading zero

&no CD transmitted Transmit UPC-E as UPC-A

A9

B9

Telepen

J1

R1

UPC (A/E)

J2

R2

UPC (A/E)+2

J3

R3

UPC (A/E)+5

J4

R4

EAN (13/8)

J5

R5

EAN (13/8) +2

Enable

 

Disable

 

 

 

6K

 

6J

6I

 

6H

IA

 

IB

HO

 

HN

 

 

 

Options for EAN-8 & EAN-13

EAN-13 Transmit CD

EAN-8 Transmit CD

Enable ISBN translation

Enable ISSN translation

J6

R6

EAN (13/8) +5

J7

R7

2 or 5

Industrial

J8

R8

2 or 5

Interleaved

JD

JZ

TriOptic

RA

R9

SCode

 

 

 

 

Enable

 

Disable

 

 

 

8E

 

 

 

 

 

8D

 

 

 

 

 

C0

 

C1

D9

 

D8*

 

 

 

D0

 

D1

 

 

 

-Y

 

 

 

 

 

Options for Code 39

Enable read of 1 or more character lengths

Enable read of 3 or more character lengths

Enable Check Digit calculation

Enable Check Digit Transmission

Enable start/stop characters transmission (*…..*)

Enables primary decode

algorithms for Code 39, I & D 2 of

Page 18

Image 21
Contents User’s Guide NFTContents Organization of this Manual Product Overview Quick Start-Up ProcedurePage Physical Specifications Symbologies SupportedOptical Specifications Skew PitchSpecified operation β at + 6º or less. Recommended at 0º Tilt Rotation 35.4RS232 Communications Specifications Electrical Specifications Operating Voltage +5VDC + 5%Environmental Specifications Connector Pin-outsOrdering Information RegulatoryAchieving Optimum Performance Distance to the Bar Code and Depth of fieldReading width or Field of View of the scanner Readable Width or Field of View for the NFT Field-of-View Specification Based Upon 69º Degree SweepAvoiding Specular Reflection Quality Bar Code LabelsMeasuring Scanner Performance Application Notes Tips for Achieving High ThroughputTips for Insuring Highest Data Integrity Tips for Verifying the Presence of a Bar Code Programming Menus & Commands Default SettingsParameter Factory Default Setting Technical Assistance and Support Common Causes of Poor PerformanceModified and/or Customized Scanners IEC 825-1 Class 1 LED Devices OpticonPage Appendix a ESC Computer Command CRWhat if you make a mistake? Reset All Defaults U2 CommandAppendix B Options for Code Direct Input Miscellaneous Characters Prefix SuffixDirect Input Alpha/Numeric Characters Direct Input Ascii Control CharactersSetting the Trigger Functions Communication DelaysSelecting the Read Mode Scanner Timeout Trigger ModeXmit Error Trigger Enabled Mode only Redundant DecodingGood Read LED Operation Delete/Deactivate Bar Code Symbologies Global Default & Scanner ConfigurationsScanner Timeout Trigger Enabled Mode only Appendix CDescription Command Symbologies Symbology SelectionComputer Function Bar Code Only MSI/PlesseyOnly EAN 13/8 +2 Symbology SelectionAdd/Activate Specific Bar Code Symbologies Add/Activate Specific Bar Code Symbologies Delete/Deactivate Bar Code SymbologiesComputer Function Command Description Disable all symbologiesDigits Add leading zero Options for UPCOptions for EAN-8 & EAN-13 7J JC JB IO IPOptions for Code 39 and IT Pharmaceutical Disable IT Pharmaceutical Options for Codabar NW-7Possible Enable normal, ABC & CX Codabar Disable ABC & Cx Codabar Page GG Enable transmit SCode as Interleaved 2 Command DescriptionF2 HF HG HJ HH HI Options for Interleaved & Industrial 2String format Meaning of Acronym Number of digits 15 total Options for IataOptions for Code-93 Options for Code-128 / EAN-128Disable length setting on all Scan Enable length setting H1 for all symbologiesI2 IL IM Creating a Prefix and/or Suffix Page UPC-E +2 or +5 Setting Prefixes Identifying the SymbologyMSI/Plessey O1 NC M9 NSetting Suffixes Identifying the Symbology O6 PC M Setting Suffixes Identifying the SymbologyDirect Input of Numeric Characters Direct Input of Alpha Characters Direct Input of Alpha Characters Lower Case Direct Input of Control Characters ETBDEL Computer Function Bar Code Command DescriptionDirect Input Characters Misc Direct Input Characters Misc Communication Parameters Terminal Communication HandshakingQ5 LB LC LD LE Communication DelaysDisable buzzer Buzzer OperationSet buzzer at 3kHz Selecting the Read Mode Setting the Trigger FunctionsUse as Com Port Command Multiple Read Mode. will readTrigger Function Enabled S8 Trigger Function Disabled S7 ModeRead Scanner’s time out Scanner may not read the same bar YB YC YD YE Add-on Wait Mode Applies to UPC/EAN onlyZM Z1 Scanner Timeout Trigger Enabled Mode onlyBI BJ BK BL BM BN BO BH Multiple Read Reset TimeQuiet Zone Options ZO ZP ZQ ZR ZS ZT ZU ZVTransmitting Error Indications XE XDRedundant Decoding Programming No read Error Messages No read error messagesUI UJ Good Read LED OperationAppendix D Appendix E NFT 2100 Depth of Field ChartAppendix F Appendix G