Manual No. | NFT 2100 CCD Fixed Mount Barcode |
Scanner |
|
For example, if a Code 39 label containing 2 characters were scanned in Step 3 then only Code 39 labels would be checked for a minimum length of 2 characters. If a second label had been read in Step 3 (immediately following the first), then that particular symbology would have been set to its associated minimum character length.
In a similar manner, the maximum length for selected codes can be established by using the “Enable maximum length for selected codes” (HM) command.
14. Creating a Prefix and/or Suffix
Computer | Function | |
Command | /Description | |
(ZZ) | START/END | |
Programming Menu | ||
| ||
|
| |
| Display Settings including | |
Z3 | Prefix/Suffix value and length | |
(expressed in hexidecimal | ||
| ||
| format) |
Bar Code
Command
[[
[!
The Z3 command can be used to instruct the scanner to provide a list of its current software settings including prefixes and suffixes.
The scanner can be programmed to transmit a prefix and/or suffix with the decoded data. A Prefix (or a Suffix) is composed of up to 4 characters. The following steps are used to establish a Prefix that will be
Example: To add the alpha character “A” as a Prefix and “B” as a
Suffix to
1.Scan “START/END Programming Mode”
2.Scan N1, representing a Prefix for
3.Scan 0A, representing the alpha character “A”
4.Scan N6, representing a Suffix for
5.Scan 0B, representing the alpha character “B”
6.Scan “START/END Programming Mode”
transmitted with the bar code data:
1.Scan Start
2.Scan the bar code representing the symbology to which you wish to add a Prefix/Suffix
3.Scan the character(s) that will comprise the Prefix/Suffix. Up to four numeric, alpha or control character(s) may be used. Scanning no characters will delete the Prefix/Suffix
4.Scan “STOP” to exit the Programming Mode.
In addition, the scanner can be programmed to transmit a preamble and/or postamble with the decoded data. A Preamble and/or postamble can be composed of up to 8 characters each and will apply to all symbologies. The following steps are used to establish a Preamble and/or postamble that will be transmitted with the bar code data:
1.Scan Start
2.Scan the MZ for preamble or PS for Postamble
3.Scan the character(s) that will comprise the Preamble/Postamble. Up to eight characters may be used. Scanning no characters will delete the Preamble/Postamble.
4.Scan “STOP” to exit the Programming Mode.
Page 39