Opticon NFT 2100 manual Options for Code

Page 22

Manual No. 25-ULNFT2100-01; Mar, 2005

NFT 2100 CCD Fixed Mount Barcode

Scanner

 

 

 

 

 

 

 

5, IATA, & Codabar

 

-Z

 

 

Alternate decode algorithm no.1

 

 

 

for Code 39

 

 

 

 

 

 

 

Enable

Disable

Options for Code 39 (cont.)

 

 

 

 

 

 

 

 

 

.S

 

 

Alternate decode algorithm no.2

 

 

 

for Code 39

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Enable

 

Disable

Options for IT Pharmaceutical

 

 

 

 

 

 

 

 

 

 

D6

 

D5

 

IT Pharmaceutical only

 

 

 

 

 

 

 

 

 

 

D7

 

D5

 

IT Pharmaceutical if possible

 

 

 

 

 

 

 

 

 

 

DB

 

DA

 

Transmit Leading A

 

 

 

 

 

 

 

 

 

 

 

 

 

Enable

Disable Options for Codabar (NW-7)

 

 

 

 

 

 

 

HC

 

 

Enable 1 character read minimum

 

 

 

 

 

 

 

HB

 

 

Enable 3 character read minimum

 

 

 

 

 

 

 

HF

 

 

Enable 5 character read minimum

 

F0

 

 

 

 

Do not transmit start/stop

 

 

 

 

characters

 

 

 

 

 

 

 

F1

 

 

Transmit start/stop as

 

 

 

ABCD/TN*E

 

 

 

 

 

 

 

 

 

 

 

 

F2

 

 

Transmit start/stop as abcd/tn*e

Enable

4H

4J

4I

4K

4L

-Y

Enable

JF

MO

Enable

+V

Disable

4M

-X

Disable

OF

MP

Disable

+W

Options for IATA

Do not calculate check digit

Calculate CD (CPN + Form + Serial)

Calculate CD (Form + Serial)

Calculate check digit (all data)

Transmit check digit

Primary/Alternative Algorithm

Options Code 128/EAN 128

EAN-128 Only

Concatenation

Options for Code 93

Concatenation

F3

 

 

 

 

Transmit start/stop as

 

 

 

 

ABCD/ABCD

 

 

 

 

 

F4

 

 

 

 

Transmit start/stop as abcd/abcd

 

 

 

 

 

 

H8

 

 

H9

Transmit check digit

H6

 

 

H7

Calculate check digit

H4

 

 

HA

Enable ABC Codabar

H5

 

 

HA

Enable Cx Codabar

H3

 

 

HA

 

Enable Normal ABC & Cx

 

 

 

Codabar

 

 

 

 

 

HH

 

 

HI

Intercharacter gap check

-Y

 

 

-X

Primary/Alternative Algorithm

 

 

 

 

 

Enable

 

 

Disable

Options for I 2 of 5 / SCode

 

 

 

 

 

G1

 

 

G0

Calculate check digit

E0

 

 

E1

Transmit check digit

GE

 

 

 

 

Enable 1 character minimum

 

 

 

 

 

 

GF

 

 

 

 

Enable 3 characters minimum

 

 

 

 

 

 

GI

 

 

 

 

Enable 5 characters minimum

GG

 

 

GH

Transmit S-Code as I 2 of 5

-Y

 

 

-X

Primary/Alternative Algorithm

 

 

 

 

 

 

 

 

Setting the Number of Digits

 

 

 

 

H1

length setting all symbologies

 

 

 

 

HK

Length setting on selected symbologies

 

 

 

 

HL

Minimum length setting on selected

 

symbologies

 

 

 

 

 

 

HM

Maximum length setting on selected

 

symbologies

 

 

 

H0

Disable length setting on all symbologies

 

 

 

Prefix

Suffix

Select Symbology for

prefix/Suffix

 

 

 

 

 

RY

RZ

All codes

 

 

 

N1

N6

UPC-A

 

 

 

M0

O0

UPC-A +2 or +5

 

 

 

N2

N7

UPC-E

 

 

 

M1

O1

UPC-E +2 or +5

 

 

 

N3

N8

EAN13

 

 

 

M2

O2

EAN-13 +2 or +5

 

 

 

N4

N9

EAN-8

 

 

 

M3

O3

EAN-8 +2or +5

 

 

 

M4

O4

Code 39

 

 

 

Page 19

Image 22
Contents NFT User’s GuideContents Organization of this Manual Quick Start-Up Procedure Product OverviewPage Symbologies Supported Physical SpecificationsOptical Specifications Pitch SkewSpecified operation β at + 6º or less. Recommended at 0º 35.4 Tilt RotationElectrical Specifications Operating Voltage +5VDC + 5% RS232 Communications SpecificationsOrdering Information Connector Pin-outsEnvironmental Specifications RegulatoryDistance to the Bar Code and Depth of field Achieving Optimum PerformanceReading width or Field of View of the scanner Avoiding Specular Reflection Field-of-View Specification Based Upon 69º Degree SweepReadable Width or Field of View for the NFT Quality Bar Code LabelsApplication Notes Tips for Achieving High Throughput Measuring Scanner PerformanceTips for Insuring Highest Data Integrity Tips for Verifying the Presence of a Bar Code Default Settings Programming Menus & CommandsParameter Factory Default Setting Common Causes of Poor Performance Technical Assistance and SupportModified and/or Customized Scanners Opticon IEC 825-1 Class 1 LED DevicesPage ESC Computer Command CR Appendix aReset All Defaults U2 Command What if you make a mistake?Appendix B Options for Code Direct Input Alpha/Numeric Characters Prefix SuffixDirect Input Miscellaneous Characters Direct Input Ascii Control CharactersSelecting the Read Mode Communication DelaysSetting the Trigger Functions Scanner Timeout Trigger ModeRedundant Decoding Xmit Error Trigger Enabled Mode onlyGood Read LED Operation Scanner Timeout Trigger Enabled Mode only Global Default & Scanner ConfigurationsDelete/Deactivate Bar Code Symbologies Appendix CDescription Command Computer Function Bar Code Symbology SelectionSymbologies Only MSI/PlesseySymbology Selection Only EAN 13/8 +2Add/Activate Specific Bar Code Symbologies Computer Function Command Description Delete/Deactivate Bar Code SymbologiesAdd/Activate Specific Bar Code Symbologies Disable all symbologiesOptions for UPC Digits Add leading zero7J JC JB IO IP Options for EAN-8 & EAN-13Options for Code 39 and IT Pharmaceutical Options for Codabar NW-7 Disable IT PharmaceuticalPossible Enable normal, ABC & CX Codabar Disable ABC & Cx Codabar Page F2 HF HG HJ HH HI Command DescriptionGG Enable transmit SCode as Interleaved 2 Options for Interleaved & Industrial 2Options for Iata String format Meaning of Acronym Number of digits 15 totalOptions for Code-128 / EAN-128 Options for Code-93Scan Enable length setting H1 for all symbologies Disable length setting on allI2 IL IM Creating a Prefix and/or Suffix Page Setting Prefixes Identifying the Symbology UPC-E +2 or +5O1 NC M9 N MSI/PlesseySetting Suffixes Identifying the Symbology Setting Suffixes Identifying the Symbology O6 PC MDirect Input of Numeric Characters Direct Input of Alpha Characters Direct Input of Alpha Characters Lower Case ETB Direct Input of Control CharactersComputer Function Bar Code Command Description DELDirect Input Characters Misc Direct Input Characters Misc Communication Parameters Communication Handshaking TerminalCommunication Delays Q5 LB LC LD LEBuzzer Operation Disable buzzerSet buzzer at 3kHz Use as Com Port Command Setting the Trigger FunctionsSelecting the Read Mode Multiple Read Mode. will readMode Trigger Function Enabled S8 Trigger Function Disabled S7Read Scanner’s time out Scanner may not read the same bar Add-on Wait Mode Applies to UPC/EAN only YB YC YD YEScanner Timeout Trigger Enabled Mode only ZM Z1Multiple Read Reset Time BI BJ BK BL BM BN BO BHZO ZP ZQ ZR ZS ZT ZU ZV Quiet Zone OptionsXE XD Transmitting Error IndicationsRedundant Decoding UI UJ No read error messagesProgramming No read Error Messages Good Read LED OperationAppendix D NFT 2100 Depth of Field Chart Appendix EAppendix F Appendix G