13. Setting the Character length that is allowed to be read.

Computer

Function

Command

/Description

 

 

(ZZ)

START/END

Programming Menu

 

 

 

H0

Disable length setting on all

symbologies

 

 

 

H1

Enable length setting on all

symbologies

 

 

 

HK

Enable length setting for selected

codes

 

 

 

HL

Enable minimum length for

selected codes

 

 

 

HM

Enable maximum length for

Selected codes

 

 

 

Bar Code

Command

[[

I1

I2 IL IM IN

%

To avoid truncation errors, the scanner can be programmed to only decode bar codes of one specific length, i.e., containing a specific number of digits. It is also possible to program the scanner to only decode bar codes of either of two specific lengths.

To set one or two lengths for all symbologies:

1.Scan “START” to enter the programming mode.

2.Scan “Enable length setting (H1) for all symbologies”.

3.Scan a sample bar code of the desired length.

4.Repeat Step #3, re-scanning the sample bar code length or a different bar code length to get 2 lengths.

5.Scan “END” to exit the programming mode

To set one or two lengths for selected symbologies:

1.Scan “START” to enter the programming mode

2.Scan “Enable length setting (HK) for selected symbologies”.

3.Scan a sample bar code of the desired length #1

4.Repeat Step #3, re-scanning the sample bar code length or a different bar code length to get 2 lengths.

5.Scan “END” to exit the programming mode

“Setting the Number of Digits” can only be applied to Code 39, NW-7, 2 of 5, and MSI/Plessey. WPC, Code 93, IATA, and Code 128 are not affected.

Setting Minimum/Maximum Length

This option modifies the default minimum length table. To use this option, perform the following steps:

1.Scan “START” to enter the programming mode

2.Scan “Enable minimum length for selected codes” (HL)

3.Scan bar codes of the required type and length.

4.Scan “END” to end the programming sequence.

Page 38

Image 41
Contents User’s Guide NFTContents Organization of this Manual Product Overview Quick Start-Up ProcedurePage Optical Specifications Physical SpecificationsSymbologies Supported Specified operation β at + 6º or less. Recommended at 0º SkewPitch Tilt Rotation 35.4RS232 Communications Specifications Electrical Specifications Operating Voltage +5VDC + 5%Environmental Specifications Connector Pin-outsOrdering Information RegulatoryReading width or Field of View of the scanner Achieving Optimum PerformanceDistance to the Bar Code and Depth of field Readable Width or Field of View for the NFT Field-of-View Specification Based Upon 69º Degree SweepAvoiding Specular Reflection Quality Bar Code LabelsTips for Insuring Highest Data Integrity Measuring Scanner PerformanceApplication Notes Tips for Achieving High Throughput Tips for Verifying the Presence of a Bar Code Parameter Factory Default Setting Programming Menus & CommandsDefault Settings Modified and/or Customized Scanners Technical Assistance and SupportCommon Causes of Poor Performance IEC 825-1 Class 1 LED Devices OpticonPage Appendix a ESC Computer Command CRWhat if you make a mistake? Reset All Defaults U2 CommandAppendix B Options for Code Direct Input Miscellaneous Characters Prefix SuffixDirect Input Alpha/Numeric Characters Direct Input Ascii Control CharactersSetting the Trigger Functions Communication DelaysSelecting the Read Mode Scanner Timeout Trigger ModeGood Read LED Operation Xmit Error Trigger Enabled Mode onlyRedundant Decoding Delete/Deactivate Bar Code Symbologies Global Default & Scanner ConfigurationsScanner Timeout Trigger Enabled Mode only Appendix CDescription Command Symbologies Symbology SelectionComputer Function Bar Code Only MSI/PlesseyOnly EAN 13/8 +2 Symbology SelectionAdd/Activate Specific Bar Code Symbologies Add/Activate Specific Bar Code Symbologies Delete/Deactivate Bar Code SymbologiesComputer Function Command Description Disable all symbologiesDigits Add leading zero Options for UPCOptions for EAN-8 & EAN-13 7J JC JB IO IPOptions for Code 39 and IT Pharmaceutical Possible Disable IT PharmaceuticalOptions for Codabar NW-7 Enable normal, ABC & CX Codabar Disable ABC & Cx Codabar Page GG Enable transmit SCode as Interleaved 2 Command DescriptionF2 HF HG HJ HH HI Options for Interleaved & Industrial 2String format Meaning of Acronym Number of digits 15 total Options for IataOptions for Code-93 Options for Code-128 / EAN-128I2 IL IM Disable length setting on allScan Enable length setting H1 for all symbologies Creating a Prefix and/or Suffix Page UPC-E +2 or +5 Setting Prefixes Identifying the SymbologyMSI/Plessey O1 NC M9 NSetting Suffixes Identifying the Symbology O6 PC M Setting Suffixes Identifying the SymbologyDirect Input of Numeric Characters Direct Input of Alpha Characters Direct Input of Alpha Characters Lower Case Direct Input of Control Characters ETBDEL Computer Function Bar Code Command DescriptionDirect Input Characters Misc Direct Input Characters Misc Communication Parameters Terminal Communication HandshakingQ5 LB LC LD LE Communication DelaysSet buzzer at 3kHz Disable buzzerBuzzer Operation Selecting the Read Mode Setting the Trigger FunctionsUse as Com Port Command Multiple Read Mode. will readRead Scanner’s time out Scanner may not read the same bar Trigger Function Enabled S8 Trigger Function Disabled S7Mode YB YC YD YE Add-on Wait Mode Applies to UPC/EAN onlyZM Z1 Scanner Timeout Trigger Enabled Mode onlyBI BJ BK BL BM BN BO BH Multiple Read Reset TimeQuiet Zone Options ZO ZP ZQ ZR ZS ZT ZU ZVRedundant Decoding Transmitting Error IndicationsXE XD Programming No read Error Messages No read error messagesUI UJ Good Read LED OperationAppendix D Appendix E NFT 2100 Depth of Field ChartAppendix F Appendix G