33. No read error messages.

The scanner can be programmed to transmit an error message when no barcode is read. The unit must be in trigger mode, then, the error message will be sent at the end of a trigger time out. 2 types of messages can be sent. The first type will indicate that no label was present or that nothing was in front of the scanner. The second type will indicated that a barcode was present but could not be decoded.

To program an error message, scan the appropriate command below then scan up to 4 direct input characters. To remove the error message, scan the appropriate command below but do not scan any direct input characters.

33. Programming No read Error Messages

Computer

Function

Command

/Description

(ZZ)

START/END

Programming Menu

 

 

 

TH

Program Error message for No

label present.

 

 

 

TI

Program Error message for label

present but not decodable.

 

 

 

34. Good Read LED Operation

Computer

Function

Command

/Description

(ZZ)

START/END

Programming Menu

 

 

 

T4

Good read LED

disabled after decode

 

 

 

T5

Good read LED ON after

decode for .20 seconds

 

 

 

T6

Good read LED ON after

decode for .40 seconds

 

 

 

T7

Good read LED ON after

decode for .80 seconds

 

 

 

Bar Code

Command

[[

UI UJ

Bar Code

Command

[[

U5

U6

U7

U8

%

Page 63

Image 66
Contents NFT User’s GuideContents Organization of this Manual Quick Start-Up Procedure Product OverviewPage Physical Specifications Symbologies SupportedOptical Specifications Skew PitchSpecified operation β at + 6º or less. Recommended at 0º 35.4 Tilt RotationElectrical Specifications Operating Voltage +5VDC + 5% RS232 Communications SpecificationsOrdering Information Connector Pin-outsEnvironmental Specifications RegulatoryAchieving Optimum Performance Distance to the Bar Code and Depth of fieldReading width or Field of View of the scanner Avoiding Specular Reflection Field-of-View Specification Based Upon 69º Degree SweepReadable Width or Field of View for the NFT Quality Bar Code LabelsMeasuring Scanner Performance Application Notes Tips for Achieving High ThroughputTips for Insuring Highest Data Integrity Tips for Verifying the Presence of a Bar Code Programming Menus & Commands Default SettingsParameter Factory Default Setting Technical Assistance and Support Common Causes of Poor PerformanceModified and/or Customized Scanners Opticon IEC 825-1 Class 1 LED DevicesPage ESC Computer Command CR Appendix aReset All Defaults U2 Command What if you make a mistake?Appendix B Options for Code Direct Input Alpha/Numeric Characters Prefix SuffixDirect Input Miscellaneous Characters Direct Input Ascii Control CharactersSelecting the Read Mode Communication DelaysSetting the Trigger Functions Scanner Timeout Trigger ModeXmit Error Trigger Enabled Mode only Redundant DecodingGood Read LED Operation Scanner Timeout Trigger Enabled Mode only Global Default & Scanner ConfigurationsDelete/Deactivate Bar Code Symbologies Appendix CDescription Command Computer Function Bar Code Symbology SelectionSymbologies Only MSI/PlesseySymbology Selection Only EAN 13/8 +2Add/Activate Specific Bar Code Symbologies Computer Function Command Description Delete/Deactivate Bar Code SymbologiesAdd/Activate Specific Bar Code Symbologies Disable all symbologiesOptions for UPC Digits Add leading zero7J JC JB IO IP Options for EAN-8 & EAN-13Options for Code 39 and IT Pharmaceutical Disable IT Pharmaceutical Options for Codabar NW-7Possible Enable normal, ABC & CX Codabar Disable ABC & Cx Codabar Page F2 HF HG HJ HH HI Command DescriptionGG Enable transmit SCode as Interleaved 2 Options for Interleaved & Industrial 2Options for Iata String format Meaning of Acronym Number of digits 15 totalOptions for Code-128 / EAN-128 Options for Code-93Disable length setting on all Scan Enable length setting H1 for all symbologiesI2 IL IM Creating a Prefix and/or Suffix Page Setting Prefixes Identifying the Symbology UPC-E +2 or +5O1 NC M9 N MSI/PlesseySetting Suffixes Identifying the Symbology Setting Suffixes Identifying the Symbology O6 PC MDirect Input of Numeric Characters Direct Input of Alpha Characters Direct Input of Alpha Characters Lower Case ETB Direct Input of Control CharactersComputer Function Bar Code Command Description DELDirect Input Characters Misc Direct Input Characters Misc Communication Parameters Communication Handshaking TerminalCommunication Delays Q5 LB LC LD LEDisable buzzer Buzzer OperationSet buzzer at 3kHz Use as Com Port Command Setting the Trigger FunctionsSelecting the Read Mode Multiple Read Mode. will readTrigger Function Enabled S8 Trigger Function Disabled S7 ModeRead Scanner’s time out Scanner may not read the same bar Add-on Wait Mode Applies to UPC/EAN only YB YC YD YEScanner Timeout Trigger Enabled Mode only ZM Z1Multiple Read Reset Time BI BJ BK BL BM BN BO BHZO ZP ZQ ZR ZS ZT ZU ZV Quiet Zone OptionsTransmitting Error Indications XE XDRedundant Decoding UI UJ No read error messagesProgramming No read Error Messages Good Read LED OperationAppendix D NFT 2100 Depth of Field Chart Appendix EAppendix F Appendix G